Laserfiche WebLink
Lighting, Motor, and E►rctrical Permit Checklist, Pg. . LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> Project Title: DSE-1-Everett WA Date 4/30/2020 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Applicability Location in building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> LIGHTING CONTROLS <br /> Lighting controls, For all lighting fixtures,indicate lighting control method on plans <br /> Yes C405.2 E0.03 <br /> general for spaces and lighting zone(s)served,or exception taken <br /> Luminaire level Indicate on plans all fixtures provided with LLLC in lieu of <br /> NA C405.2 lighting controls C405.2 lighting controls;provide description of control <br /> (LLLC) capabilities and performance parameters <br /> For permanently installed lighting fixtures in dwelling units, <br /> NA C405.1 Lighting in dwelling indicate lighting control method on plans for spaces and <br /> units lighting zone(s)served,or demonstrate compliance with high <br /> efficacy exception <br /> C405.2.3 Indicate on plans the method of manual lighting control(whether <br /> C405.2.1.1 combined with occupancy sensor,automatic light reduction, <br /> Yes C405.2.2.2 Manual controls E1.11-E1.12 <br /> daylight responsive or specific application controls),location of <br /> C405.2.4 manual control device and area or specific application it serves <br /> C405.2.5 <br /> C405.2.2.1 Indicate on plans which method of manual 50%lighting load <br /> Yes C405.2.2.2 Manual interior light reduction is provided,or whether lighting load is reduced via E1.11-E1.12 <br /> C405.2.3 reduction controls occupancy sensors or daylight responsive controls <br /> Indicate on plans the method of automatic shut-off control during <br /> unoccupied periods(occupancy sensor,time switch or digital E1.11-E1.12 <br /> Yes C405.2.2 Method of automatic timer switch)for all lighting zones; <br /> shut-off control Indicate locations where automatic shutoff is provided by other <br /> methods(occupancy sensor or digital timer switch)or which E1.11-E1.12 <br /> time switch control exception applies <br /> Indicate on plans the spaces served by occupancy sensors <br /> NA C405.2.1 Occupancy sensor Indicate whether occupancy sensor controls are configured to be <br /> C405.2.1.1 controls manual-on,automatic 50%-on,or serve a space eligible for <br /> automatic 100%-on per exception <br /> Occupancy sensor Indicate aisleways and open areas in warehouse spaces <br /> NA C405.2.1.2 controls- provided with occupancy sensor controls that reduce lighting " <br /> warehouses power by 50% <br /> Automatic time switch Indicate locations of override switches on plans and the lighting <br /> Yes C405.2.2.1 E1.19-E1.92 <br /> controls zone(s)served,include area so.ft. <br /> Yes C405.2.6 Digital timer switch Indicate digital timer switch control includes:manual on/off,time E1.11-E1.12 <br /> delay.audible and visual indication of impending time-out <br /> Indicate primary and secondary sidelight daylight zone areas on <br /> plans,include sq.ft.; <br /> C405.2.4.2 Daylight zones- Indicate toplight daylight zone areas on plans,include sg,ft. __wV_ <br /> NA For small vertical fenestration assemblies(rough opening less <br /> C405.2.4.3 Sidelight and toplight than 10 percent of primary daylight zone)where daylight <br /> responsive controls are not required,provide fenestration area tc <br /> davliaht zone calculation(s) <br /> Indicate on plans lighting zone(s)served by daylight responsive <br /> controls; <br /> Identify sidelight and toplight daylight zones that are not <br /> provided with daylight sensing controls and the exception(s)that <br /> NA C405.2.4 Daylight responsive apply; <br /> controls Indicate on plans the lighting load reduction method- <br /> continuous dimming,or stepped dimming that provides at least <br /> two even steps between 0%-100%of rated power _` <br /> Indicate that daylight sensing controls are configured to <br /> • completely shut off all controlled lights in the lighting zone <br /> Additional controls Identify spaces and lighting fixtures on plans that require <br /> NA C405.2.5 Specific application specific application lighting controls per this section <br /> lighting controls <br /> Indicate on plans that display and accent lighting,and display <br /> C405.2.5- Display and accent case lighting are controlled independently from both general <br /> NA Items 1&2 lighting area lighting and other lighting applications within the same <br /> AMC <br /> Indicate manual and automatic lighting control method <br /> 1 <br />