My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6617 ASSOCIATED BLVD AMAZON 2023-12-06
>
Address Records
>
ASSOCIATED BLVD
>
6617
>
AMAZON
>
6617 ASSOCIATED BLVD AMAZON 2023-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 8:48:35 AM
Creation date
11/13/2023 11:50:57 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6617
Tenant Name
AMAZON
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting, Motor, and Eln.,ctrical Permit Checklist, Pg. _ LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> Project Title: DSE-1-Everett WA Date 4/30/2020 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Applicability Location in building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> C405.2.5- Hotel/motel guest Indicate method of automatic control-vacancy or captive key <br /> NA Item 3 rooms control of all installed luminaires and switched receptacles in <br /> quest room <br /> C405.2.5- Supplemental task Indicate method and location of automatic shut-off vacancy <br /> NA Item 4 lighting control for supplemental task lighting,Including under-shelf or <br /> under-cabinet lighting <br /> Indicate on plans eligible non-visual lighting applications, <br /> include sq.ft.area of each lighting control zone <br /> C405.2.5- Lighting for non- Indicate on plans that non-visual lighting are controlled <br /> NA Item 5 visual applications independently from both general area lighting and other lighting <br /> applications within the same space;, _�_...,_. ._n _ _.w. ...._.m...... ..a._....,...,_.__ _,... ____ ._..__._..v_w_... .... <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Indicate on plans that lighting equipment for sale or <br /> Lighting equipment demonstration are controlled independently from both general <br /> NA C405.2.5- for sale or area lighting and other lighting applications within the same <br /> Item 6 demonstration Space' - - <br /> Indicate method of manual lighting control and applicable <br /> automatic lighting control <br /> Identify on plans egress fixtures that function as both normal E1.11-E1.12 <br /> and emergencyy means of egress illumination <br /> Rrovide ca cu a ion of lighting <br /> g g power density oTtofaTegress E1.11-E1.12 <br /> Yes C405.2.5- Means of egress lighting; <br /> Item 7 lighting It total egress lighting power density is greater than 0.02 W/sq. <br /> ft.,indicate on plans egress fixtures requiring automatic shut-off E1.11-E1.12 <br /> during unoccupied periods; <br /> Indicate method of automatic shut-off contro E1.11-El.12 <br /> Indicate on exterior lighting plans and fixture schedules the <br /> automatic lighting control method,control sequence,and E1.11-E1.12 <br /> locations served; <br /> For building facade and landscape lighting,indicate automatic <br /> Exterior lighting controls shut off,lighting as a function of dawn/dusk and fixed E1.11-E1.12 <br /> Yes C405.2.7 controls opening/closing time ____ r . <br /> For all other exterior lighting,indica e automatic controls 1i iiToff <br /> lighting as a function of available daylight;include control <br /> sequence that also reduces lighting power by at least 30% E1.11-E1.12 <br /> between 12am-6am,or from 1 hour after closing to 1 hour <br /> before opening,or based upon motion sensor <br /> Exterior building For building grounds fixtures greater than 100 watts,indicate on <br /> Yes C405.5.1 grounds lighting plans whether fixtures have efficacy greater than 80 lumens or; E1.11-E7.12 <br /> controls are controlled by motion sensor,or are exempt lighting per <br /> C405.5.2 <br /> Area controls- Indicate location(s)of master control switch(es)intended to <br /> C405.2.5 Master control control multiple independent switches;circuit breaker may not E1.11-E1.12 <br /> Yes (listed after be used as a master control switch <br /> switches and circuit <br /> C405.2.7) power limit Verify that no 20 amp circuit controlled by a single switch or E1.11-E1.12 <br /> automatic control is loaded beyond 80/o <br /> ADDITIONAL EFFICIENCY PACKAGE OPTION -ENHANCED DIGITAL LIGHTING CONTROLS <br /> To comply with additional efficiency package option,indicate on <br /> plans all interior lighting fixtures that are individually addressed <br /> Enhanced digital and provided with continuous dimming,or exception taken; <br /> NA C406.4 <br /> lighting controls Include calculation of percent total installed interior lighting <br /> power that is configured with required enhanced lighting control <br /> functions(min 90%to comply with additional efficiency package <br /> option) <br /> 8 / I <br />
The URL can be used to link to this page
Your browser does not support the video tag.