2 I B9512G Control Panel <br /> System response • Dual authentication. Requires two forms of <br /> • High-performance micro-controller provides industry identification before processing certain system <br /> leading system response commands, including turning off the system and <br /> • 63 point indexes opening doors.A standard system user must have a <br /> • Selectable point response time passcode,a credential (token or card),and <br /> • Selectable EOL resistor configuration, single or dual appropriate command authority permissions assigned <br /> • Cross point capability in the door and keypad's assigned area. <br /> • Fire alarm verification <br /> • Dangerous gas indicator includes carbon monoxide Easy exit control <br /> (NFPA 720) The control panel changes from one On (armed) state <br /> • Watch mode to another without turning off(disarming) the system. <br /> • Scheduled events (SKEDs) perform several functions, For example, if you change the state from Part On <br /> such as turn on (arm) the system,turn off(disarm) (Perimeter Arm) to All On (Master Arm),the control <br /> the system, bypass and unbypass points,and control panel complies and reports the change. Easy Exit <br /> outputs Control reduces the number of keystrokes, simplifying <br /> User interface system operation. <br /> • Supervision of up to 32 keypads Programmable passcode-controlled menu list <br /> • Custom keypad text is fully programmable through Passcode-controlled shortcuts provide users,only with <br /> RPS the options and information pertinent to them, <br /> • Full function menu including customizable shortcuts simplifying system operation. <br /> • Authority by area and 32 character name for each <br /> user Flexible control <br /> • 14 custom authority levels control user's authority to The system provides the flexibility to choose added <br /> change,add,or delete passcodes to disarm or bypass convenience or high security. For example,you can <br /> areas,and to start system tests restrict to a keypad's immediate local area turning on <br /> • Programmable primary and secondary language by (arming) and turning off(disarming) the system with a <br /> user and keypad;select from English, Spanish, passcode, even if the user has access to other areas. <br /> French,and Portuguese This is particularly useful for high security areas, <br /> Area configuration where a user may have access to the area, but would <br /> Area programming offers a wide selection of different prefer to only turn off(disarm) the area individually <br /> system configurations. Make area arming conditional rather than with the rest of the system.Another option <br /> on other areas(master or associate), if desired.You is to program the system to turn off all areas the user <br /> can configure any area for perimeter and interior can access from any keypad. <br /> arming, not requiring a separate area for this function. Monitor Delay/Delayed Response <br /> Link multiple areas to a shared area which is Create a special point index that delays the reaction of <br /> automatically controlled (hallway or lobby). For higher a point for a specified time (up to 1 hour in minutes <br /> security applications,the Area Re-Arm feature and seconds).This delay provides time for the <br /> guarantees that areas are always rearmed, and are specified condition to reset before activating any <br /> disarmed for no longer than a specific, configurable, annunciation. The system can annunciate locally and <br /> amount of time (for example,service time). send a report, if desired. When the system is armed, <br /> Custom functions the point can respond like a normal point— providing <br /> For added convenience,the installer can program dual functionality. Use this feature to ensure that <br /> custom functions that allow customers to complete perimeter doors have not been propped open, or to <br /> complex tasks with one simple action. For example, a monitor critical areas such as computer rooms and <br /> custom function can bypass a group of points and arm safes,for example. <br /> the system,allowing the user to perform these System users <br /> functions with one easy command. Users can activate The system supports up to 2,000 users. Each user can <br /> custom functions with a keypad keyfob,token, or have a personalized passcode, a wireless keyfob, and a <br /> card,or the control panel can activate a function in credential to control the system. User passcodes <br /> reaction to a faulted point,or automatically through a contain three to six digits.You can assign passcodes <br /> scheduled event (SKED). to one of 14 customized authority levels in each area <br /> Passcode security that can be restricted to operate only during certain <br /> • Two-man rule. Requires two people with two unique times.You can program a primary and secondary <br /> passcodes to be present at the time of opening. language for each user and by keypad(select from <br /> • Early ambush.Allows users to verify that the facility is English, Spanish, French, and Portuguese). The keypad <br /> safe by requiring two passcodes.The control panel changes to the user's programmed language when the <br /> sends a duress event if the user does not enter the user enters his passcode or holds the Help key. <br /> passcode a second time after inspecting the <br /> premises. <br />