1715 BROADWAY 2023 Plans 2023-11-20
>
Address Records
>
BROADWAY
>
1715
>
Plans
>
1715 BROADWAY 2023 Plans 2023-11-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 11:15:00 AM
Creation date
11/17/2023 2:56:29 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
1715
Permit
FA2304-012
Year
2023
Notes
REPLACE FIRE SPRINKLER MONOTOR PANEL AND REMOTE ANNUNCIATOR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 I B9512G Control Panel <br /> Communication formats destinations using a combination of cellular phone <br /> The control panel prioritizes and sends reports to four numbers and email addresses.The control panel sends <br /> route groups. Network and phone communications can notifications in the user's programmed primary <br /> use either the Modem4 or the Contact ID language. <br /> communications formats. Each group has a <br /> programmable primary and backup destination. Firmware updates <br /> The control panel provides flexible communications for The system allows remote firmware updates through <br /> most central stations with reporting capabilities such Remote Programming Software (RPS) using the RPS <br /> as: Firmware Update Wizard.The Firmware Update Wizard <br /> • Individual point numbers uses the on-board USB connection or the on-board <br /> • Opening or closing reports by user and area number Ethernet (IP) connection (the on-board Ethernet port <br /> • Remote programming attempts is excluded on "E"versions) to transmit firmware <br /> • Diagnostic reports updates. <br /> The control panel can optionally receive firmware <br /> Notice updates from RPS using a 6426 Conettix Ethernet <br /> For premises equipment used in the Communication Module or a Conettix Plug-in Cellular <br /> communication path,such as routers, use only UL Communicator (6440/B441/6442/B443). Notice! <br /> listed equipment. Cellular firmware updates require more time than <br /> Ethernet updates and carrier data rates apply. <br /> IP communication • Control panel updates. Remotely update the control <br /> The control panel uses on-board Ethernet (IP) panel firmware for easy feature enhancements <br /> connection (the on-board Ethernet port is excluded on without replacing ROM chips. <br /> • Module update support. Remotely update the <br /> "E"versions) to communicate with a Conettix D6600 firmware on connected SDI2 modules for easy feature <br /> or a Conettix D6100IPv6 Communications Receiver/ enhancements without visiting each individual <br /> Gateway. module. <br /> The control panel can optionally communicate with a <br /> Conettix D6600 or a Conettix D6100IPv6 A wide variety of input options <br /> Communications Receiver/Gateway using a B426 Each point: <br /> Conettix Ethernet Communication Module or a • Accommodates normally open (NO) and <br /> Conettix Plug-in Cellular Communicator(B440/B441/ normally closed (NC) devices with end-of-line(EOL) <br /> B442/B443). resistor supervision. <br /> Using Conettix IP communication offers a secure path • Accepts programming for fire,gas,fire supervisory,or <br /> that includes anti-replay/anti-substitution features and intrusionuppothardwiapplicared . <br /> • Supports hardwired and wireless devices. <br /> provides enhanced security with AES 256-bit • Supports IP cameras by Bosch as point sources. <br /> encryption (using Cipher Block Chaining (CBC)). <br /> The control panel supports Domain Name System IP camera support <br /> (DNS) for both remote programming and central The control panel can use its on board Ethernet to <br /> station communication. DNS provides ease of use, connect directly to Bosch IP cameras. The control <br /> eliminating the need to use static IP addresses as your panel communicates with Bosch IP cameras,allowing <br /> reporting destination,and accommodates a simple the camera's video motion detection to activate points <br /> solution for central station disaster recovery. IP Setup on the control panel and control panel events to <br /> is available via the keypad Installer menu and the trigger camera actions, including sending video <br /> remote programming software, eliminating the need to snapshots via email. <br /> use complicated internet programming tools such as Security and fire detection <br /> ARP and Telnet.The control panel supports both IPv6 The control panel provides eight on-board points, and <br /> and IPv4 networks. up to 591 additional off-board points (depending on <br /> For more information on the enhanced model and expansion interfaces).You can program <br /> communications capabilities, refer to RPS Help or the individual points to monitor some types of burglar <br /> control panel's Program Entry Guide. alarms,fire alarms,and supervision devices. <br /> Communication paths Event log <br /> The control panel accommodates up to four separate The event log stores up to 10192 local and reported <br /> phone and four separate network paths to the central events.The event log includes time,date, event, area, <br /> station receiver. When resetting alarms or turning a point, and user.View the event log from a keypad or <br /> system on and off,the user is identified by name and use RPS to remotely retrieve event information. When <br /> number. the event log reaches a programmed threshold of <br /> Personal notification stored events, it can send an optional report to a <br /> The control panel can send text messages and emails receiver. <br /> for personal notification over Ethernet or using a <br /> cellular communicator.You can configure up to 32 <br />