Laserfiche WebLink
3 I B9512G Control Panel <br /> Communication formats destinations using a combination of cellular phone <br /> The control panel prioritizes and sends reports to four numbers and email addresses.The control panel sends <br /> route groups. Network and phone communications can notifications in the user's programmed primary <br /> use either the Modem4 or the Contact ID language. <br /> communications formats. Each group has a <br /> programmable primary and backup destination. Firmware updates <br /> The control panel provides flexible communications for The system allows remote firmware updates through <br /> most central stations with reporting capabilities such Remote Programming Software (RPS) using the RPS <br /> as: Firmware Update Wizard.The Firmware Update Wizard <br /> • Individual point numbers uses the on-board USB connection or the on-board <br /> • Opening or closing reports by user and area number Ethernet (IP) connection (the on-board Ethernet port <br /> • Remote programming attempts is excluded on "E"versions) to transmit firmware <br /> • Diagnostic reports updates. <br /> The control panel can optionally receive firmware <br /> Notice updates from RPS using a 6426 Conettix Ethernet <br /> For premises equipment used in the Communication Module or a Conettix Plug-in Cellular <br /> communication path,such as routers, use only UL Communicator (6440/B441/6442/B443). Notice! <br /> listed equipment. Cellular firmware updates require more time than <br /> Ethernet updates and carrier data rates apply. <br /> IP communication • Control panel updates. Remotely update the control <br /> The control panel uses on-board Ethernet (IP) panel firmware for easy feature enhancements <br /> connection (the on-board Ethernet port is excluded on without replacing ROM chips. <br /> • Module update support. Remotely update the <br /> "E"versions) to communicate with a Conettix D6600 firmware on connected SDI2 modules for easy feature <br /> or a Conettix D6100IPv6 Communications Receiver/ enhancements without visiting each individual <br /> Gateway. module. <br /> The control panel can optionally communicate with a <br /> Conettix D6600 or a Conettix D6100IPv6 A wide variety of input options <br /> Communications Receiver/Gateway using a B426 Each point: <br /> Conettix Ethernet Communication Module or a • Accommodates normally open (NO) and <br /> Conettix Plug-in Cellular Communicator(B440/B441/ normally closed (NC) devices with end-of-line(EOL) <br /> B442/B443). resistor supervision. <br /> Using Conettix IP communication offers a secure path • Accepts programming for fire,gas,fire supervisory,or <br /> that includes anti-replay/anti-substitution features and intrusionuppothardwiapplicared . <br /> • Supports hardwired and wireless devices. <br /> provides enhanced security with AES 256-bit • Supports IP cameras by Bosch as point sources. <br /> encryption (using Cipher Block Chaining (CBC)). <br /> The control panel supports Domain Name System IP camera support <br /> (DNS) for both remote programming and central The control panel can use its on board Ethernet to <br /> station communication. DNS provides ease of use, connect directly to Bosch IP cameras. The control <br /> eliminating the need to use static IP addresses as your panel communicates with Bosch IP cameras,allowing <br /> reporting destination,and accommodates a simple the camera's video motion detection to activate points <br /> solution for central station disaster recovery. IP Setup on the control panel and control panel events to <br /> is available via the keypad Installer menu and the trigger camera actions, including sending video <br /> remote programming software, eliminating the need to snapshots via email. <br /> use complicated internet programming tools such as Security and fire detection <br /> ARP and Telnet.The control panel supports both IPv6 The control panel provides eight on-board points, and <br /> and IPv4 networks. up to 591 additional off-board points (depending on <br /> For more information on the enhanced model and expansion interfaces).You can program <br /> communications capabilities, refer to RPS Help or the individual points to monitor some types of burglar <br /> control panel's Program Entry Guide. alarms,fire alarms,and supervision devices. <br /> Communication paths Event log <br /> The control panel accommodates up to four separate The event log stores up to 10192 local and reported <br /> phone and four separate network paths to the central events.The event log includes time,date, event, area, <br /> station receiver. When resetting alarms or turning a point, and user.View the event log from a keypad or <br /> system on and off,the user is identified by name and use RPS to remotely retrieve event information. When <br /> number. the event log reaches a programmed threshold of <br /> Personal notification stored events, it can send an optional report to a <br /> The control panel can send text messages and emails receiver. <br /> for personal notification over Ethernet or using a <br /> cellular communicator.You can configure up to 32 <br />