LEGEND: <br /> JQ JUNCTION BOX 4S UNLESS NOTED OTHERWISE <br /> OS IONIZATION SMOKE DETECTOR <br /> O HEAT DETECTOR FIXED 135° <br /> ❑F MANUAL STATION, DOUBLE ACTING <br /> TO BUILDINGS 45-280 & 281 ® STROBE ALARM <br /> SHEET (1E261) <br /> ®Q AUDIBLE/VISUAL ALARM <br /> 5 4 4 2 e FIRE ALARM PANEL <br /> ® TELEPHONE PANEL <br /> 3/4"C 2#16 o ADT PANEL <br /> GENERAL NOTES <br /> 45-280 & 45-281 ARE MONITORED BY <br /> 45-244 BUILDING FACP. <br /> STORAGE MENS TOILET <br /> 2 07 S N0. 1 1o3 REFERENCE DRWAWINGS <br /> 45-244-1E60POWER PLAN VIEW <br /> 45-280-1E260 TOOL STORAGE FIRE ALARM PLAN <br /> BUILDING FACP n �45-006-E506 FIRE ALARM DETAILS <br /> - FAC 1 <br /> 1 2#14 s SMK FACP CREW AREA VESTIBULE CONSTRUCTION NOTES <br /> SUPERVISOR AR A 3 ZONE #:01, L1:01 105 104 <br /> 108 3 THIS FIRE ALARM DESIGN IS INTENDED TO BE <br /> F SMK MEN RESTROOM A PRELIMINARY DESIGN TO DIRECT A NICET <br /> ZONE #:06, L1:06 CERTIFIED DESIGNER TO COMPLETE FINAL FIRE <br /> MAN PULL DR W1 O ALARM DESIGN IN ACCORDANCE WITH ALL <br /> SMK OFFICE N ZONE #:07, L1:07 D APPLICABLE LAWS AND CODES. APPLICATION <br /> FOR FIRE ALARM PERMIT USING FINAL STAMPED <br /> SMK OFFICE S SMK OFFICE CENTER <br /> ZONE #:02, _1:02 A DRAWINGS IS REQUIRED. <br /> 3 <br /> ZONE #:04, L1:04 ZONE #:03, L1:03 aO 1/2"C 2#14 3 5CD <br /> O 30CD �O 30CD PROVIDE AND INSTALL NEW DIGITAL <br /> - - - - - - - - <br /> 1/2"C 2 14 PHENOS CABLL LABEL IOLDINPANEL T THAT G FACDVIDL <br /> READS: <br /> 3 1/2"C 2#14 3 O <br /> 20VAC <br /> MAN PULL DR E1 EVT-FA- FIRE ALARM CONTROL PANEL <br /> ZONE #:08, L1:08 145-244 <br /> 20VAC FED FROM PANEL 'XS2V27-244/9b' <br /> SV45-45 HI/LO AIR SMK WOMEN ROOM <br /> 3 PS ZONE #:10, _1:10 MAN PULL DR E2 3 F ZONE #:05, L1:05 PROVIDE CELLULAR COMMUNICATOR AND WIRE <br /> ZONE #:09, _1:09 TO BUILDING FACP. SEE SHEET E506 FOR <br /> 3 Ps F 15CD INSTALLATION DETAILS. <br /> SV45-45 WE PRESSURE VESTI B I L 3 3 <br /> ZONE #:11, L1:11 <br /> 102 F PE:�- REPLACE EXISTING FIRE ALARM DEVICE WITH <br /> B NEW COMPATIBLE DEVICE. NICET CERTIFIED <br /> TECHNICIAN TO DESIGN ADDITIONAL HORNS AND <br /> S N0. 3 VESTIBULE SFAIF NO. 2 STROBES AS REQUIRED BY BUILDING FIRE <br /> 106 WOMENS CODE. REUSE CONDUIT AND WIRE WHERE <br /> TOILET POSSIBLE. (TYP. 6 SMOKES, 3 MANUAL PULL <br /> 01 STATIONS, 4 PS, 1 HORN/STROBES, 2 <br /> STROBES) <br /> ® UTILIZE EXISTING UNISTRUT SUPPORT FOR <br /> CONDUIT BETWEEN 45-280 AND 45-244. <br /> FLOOR <br /> FILL OUT AND RETURN ATTACHED BUILDING <br /> C <br /> FLOOR PLAN IRE ALARM PLAN FACP POINTLIST TO ENGINEER A MINIMUM OF 3 <br /> SCALE: 1/4" = 1'-0" <br /> V WEEKS PRIOR TO FINAL ACCEPTANCE TESTING. <br /> 6, SEE DRAWING 45-280-1E260 FOR 4 <br /> ADDITIONAL FIRE ALARM POINTS. <br /> SV45-43 WE PRESSURE <br /> ZONE #:12, L1:12 <br /> SV45-43 HI/LO AIR <br /> ZONE #:13, L1:13 <br /> PS PS 3 <br /> 3 <br /> RISER ENCLOSURE EAST OF STALL F5 FIRE ALARM PLAN 4' 2 O 2' 4' 8' <br /> SCALE: 1/4" = 1'-0" <br /> SCALE: 1/8" <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> NEW FACP REPLACEMENT 27851053 DRM MDK 08.29.22 <br /> THIS DESIGN BANDI/R CHECKED 6 15 92 FIRE ALARM FLOOR PLAN <br /> 27851053 A 04.28.23 <br /> SPECIFICATION IS APPROVED EWE 6/15/92 SHEET m <br /> BOE//VG® TITLE <br /> A SHOP DRAWINGS AGOW JS 04.28.23 <br /> / APPROVED BY DEPT. DATE C <br /> CHECKED C .. <br /> 260 <br /> BUILDING 45-244 <br /> , Ln JOB NG COMP NO. <br /> - <br /> 244-1E26045g <br /> APPROVED ELECTRICAL MASTER COL. A-13/1-5 EVERETT, WA DWG NO. 45-244-1E260 <br />