My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-244 2023-11-29
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-244
>
3003 W CASINO RD BLDG 45-244 2023-11-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 11:30:17 AM
Creation date
11/22/2023 7:04:45 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-244
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FACP BATTERY CALCULATIONS PEM POWER CABLE (SUPPLIED <br /> COMPONENTS QTY. STANDBY ALARM 6 5 WITH PEM) <br /> CURRENT CURRENT <br /> AFC-100(FACP) 1 OA 3000A 0.22000A <br /> UD-2000(DACT) 1 0.01600A 0.02300A <br /> SLC DEVICES SUPERVISORY ALARM <br /> CURRENT CURRENT <br /> PAD-PD 7 0.00030A 0.00030A 0.00210A 0.00210A <br /> PAD-HD 2 0.00030A 0.00030A 0.00060A 0.00060A <br /> PAD-DUCT 0 0.00030A 0.00030A 0.000OOA 0.000OOA <br /> PAD100-PSSA/PSDA 3 0.00020A 0.00020A O.00060A o.00060A [j_:::-3/4"C - 2#14THHN,1#14G Z <br /> PAD100-RM 0 0.00024A 0.00024A 0.000OOA 0.000OOA TG-PEM <br /> PAD100-MIM 4 0.00020A 0.00020A <br /> 0.00080A 0.00080A jPAD100-DIM 0 0.00024A 0.00024A 0.000OOA 0.000OOA <br /> STANDBY ALARM FACP EVF-FA-45-244 I TG-7 ES <br /> CURRENT CURRENT (BY FIRE ALARM VENDOR) "" 1 1 4 7 <br /> NAC CKT 1(AUX PWR) 0.018A OA1000A 0.01800A 0.11000A <br /> NAC CKT 2 O.00A 0.26oA O.000o2 0.260A R <br /> - O.00A O.O2oOo00A 0.000, 20OA O.000OOA JG SLC ALARM LED O.00A 0.03600A O.000OOA 0.03600A T <br /> OTAL OA6810A 0.6551A <br /> TOTAL STANDBY CURRENT DRAW= 0.1681 AMPS DC STC2 STCI TRIP BATT AC <br /> X STANDBY TIME 48 HOURS <br /> 12123456 123 12 <br /> ~ ~ZE STANDBY AMP HOUR TOTAL= 8.069 AH BB (D I&s0 BB <br /> N N TOTAL ALARM CURRENT DRAW= 0.6551 AMPS <br /> O O X ALARM TIME 0.167 HOURS eLK <br /> L` ALARM AMP HOUR TOTAL= 0.109 AH RED EOL(q5 NEEDED) <br /> W O W STANDBY AH + ALARM AH = 8.18 AH <br /> = 3 X DE-RATING FACTOR 1.20(20%) <br /> TOTAL AH REQUIRED = 9.82 AH <br /> w w W w MINIMUM BATTERY SIZE NEEDED: 10 AH 3/4"G - (1) PHONE GABLE, <br /> Z Z Z Z Z z BATTERY SIZE PROVIDED: 12 AH (1) 2 CONDUCTOR FPL OR <br /> a NOTE: 0.167 EQUALS 10 MINUTES OF ALARM TIME APPROVED EQUAL-< <br /> I I I I N N N N <br /> FACP VOLTAGE DROP CALCULATION <br /> aN/A20.4 <br /> SUPPLY ALARM OHMS NGT TOTAL LAST DEVICE VOLTAG CONSTRUCTION NOTES <br /> LO LQ S $ $ $ VOLTAGE CURRENT WIRE TYPE 000 F. EET RESISTANCE VOLTAGE DROP <br /> L1:10 L1:11 _1:12 L1:13 _1:14 _1:15 _1:16 _1:17 20.4 VDC 0.110 A #14AWG SOLID 3.07 10 0.0614 20.393 VDC 0.03% FIRE ALARM SYSTEM COMMUNICATIONS DETAIL <br /> 20.4 VDC 0.262 A #14AWG SOLID 3.07 108 0.6631 20.23 VDC 0.85% SCALE: NONE PROVIDE CELLULAR DIALER, AND MOUNT ADJACENT TO <br /> E260 E506 THE BUILDING FACP. CONFIGURE DIALER TO PROVIDE <br /> VDC 0.000 A #14AWG SOLID 3.07 0 0 00.00 VDC o% SOLE PATH COMMUNICATION. DIALER SHALL BE <br /> zo.4 voc 0.000 A #14AWG SOLID 3.07 0 00.00 VDC o% COMPATIBLE WITH AT&T CELL SERVICE. <br /> w D:::�, PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> o a o z z a STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL INDICATED ON FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> z Q DRAWINGS. IF ACCEPTABLE *SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. <br /> g � � ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> a a a o 0 0 STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> =g = TO IDENTIFY LOCATION(S) SUITABLE FOR INSTALLATION OF REMOTE/EXTERNAL CELLULAR ANTENNA. BUILDING FACP. <br /> F F F S S S S CELLULAR MONITORED BY TYCO AND COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR 3 PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> L1:09 _1:08 L1:07 L1:06 L1:05 L1:04 L1:03 L1:02 L1:01 SLC ANAL G PHON LINE DIALER SIGNAL SENT TO CENTRAL APPROVAL PRIOR TO ROUGH-IN AND SKIP TO STEP 4. POWER AND EARTH GROUND FROM THE BUILDING FACP <br /> ((PRIMARY TG-7FS-A BOEING FIRE DEPARTMENT STEP 3: IF ACCEPTABLE *SIGNAL STRENGTH IS NOT ACHIEVED WITHIN 20FT OF ORIGINAL PROPOSED LOCATION FOR POWER SUPPLY. PROVIDE POWER AND EXPANSION <br /> TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY CODE, AS SHOWN. CELLULAR COMMUNICATOR PANEL, PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE MODULE AND WIRE AS SHOWN. MAINTAIN <br /> 45-244 FACP 'S REQUIRED 14' SEPARATION <br /> WITH BOEING AND SPACE USERS FOR POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. MANUFACTURER / <br /> BETWEEN POWER AND COMMUNICATION WIRING. <br /> STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE <br /> 15CD 15CD 30CD 30CD NAC2 FROM CELLULAR COMMUNICATOR To THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED ® PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> ANALOG PHONE LINE WITHIN 20FT OF EACH OTHER. BACKGROUND, THAT READS: <br /> (SECONDARY) STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR FROM <br /> EVF-FA-45-244 BUILDING FACP. "FIRE ALARM CELLULAR DIALER" <br /> ---L, <br /> STEP 6: PROVIDE REQUIRED SET-UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A STRENGTH IN ACCORDANCE WITH DETAIL 2. INSTALL <br /> XS2V27-244/9b' SOLE PATH FOR FIRE COMMUNICATIONS. CONDUIT AND EXTENDED ANTENNA CABLE AS <br /> NECESSARY TO REMOTE MOUNT ANTENNA IF COVERAGE <br /> BUILDING FIRE ALARM SYSTEM RISER IS NOT SUITABLE AT FACP LOCATION. UPDATE BOM <br /> SCALE: NONE E506 *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURERS SPECIFICATIONS AND LOCAL AHJ WITH SELECTED CABLE LENGTH AND PROVIDE REDLINES <br /> ORDINANCES. TO BOEING ENGINEER. <br /> 45-244 BUILDING SYSTEM FACP POINTS © FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> WHITE LETTERING, RED BACKGROUND, THAT READS: <br /> POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT - COMMENTS - GRID/SHEET LOC. CELLULAR COMMUNICATOR INSTALLATION SEQUENCE "FIRE ALARM CELLULAR ANTENNA" <br /> L1:001 1 45-244 SMK @ FACP 244 FACP SMOKE DETECTOR - 3A/E260 SCALE: NONE E260 E506 <br /> L1:002 2 45-244 SMK OFFICE N 244 OFFICE SMOKE DETECTOR NORTH 2A/E260 7� INSIDE CELL ENCLOSURE POST COMMUNICATOR <br /> L1:003 3 45-244 SMK OFFICE CENTER 244 OFFICE SMOKE DETECTOR CENTER 3A/E260 SETTINGS AND CEPHONE NUMBER. PROVIDE <br /> PRINTED LABEL, HAANDWNDW RITTEN INFORMATION IS NOT <br /> _1:004 4 45-244 SMK OFFICE S 244 OFFICE SMOKE DETECTOR SOUTH 4A/E260 ACCEPTABLE. PROVIDE SETTINGS AND CELLULAR <br /> L1:005 5 45-244 HEAT WOMENS R.R. 244 WOMENS R.R. HEAT DETECTOR - 1B/E260 INFORMATION TO BOEING ENGINEER. <br /> _1:006 6 45-244 HEAT MENS R.R. 244 MENS R.R. HEAT DETECTOR - 1A/E260 <br /> L1:007 7 45-244 MAN PULL DR W1 244 MANUAL PULL STATION @ DOOR W1 - 1A/E260 BILL OF MATERIALS <br /> L1:008 8 45-244 MAN PULL DR E1 244 MANUAL PULL STATION @ DOOR E1 - B1/E260 ITEM QTY. PART NO. MANUFACTURER DESCRIPTION <br /> _1:009 9 45-244 MAN PULL DR E2 244 MANUAL PULL STATION @ DOOR E2 - B3/E260 1 1 3992753 POTTER FIRE ALARM CONTROL PANEL <br /> L1:010 10 SV45-45 HI LO AIR SV45-45 SPRINKLER HI-LOW AIR SWITCH - 5B/E260 2 1 3992769 POTTER UD-2000 DACT CARD <br /> L1:011 11 SV45-45 WF PRESSURE SV45-45 SPRINKLER WATER FLOW SWITCH - 5B/E260 3 9 3992732 POTTER PAD100 6° BASE <br /> _1:012 12 SV45-43 HI Lo AIR SV45-43 SPRINKLER HI-LOW AIR SWITCH - E260 4 7 3992770 POTTER PAD200 PHOTO DETECTOR <br /> _1:013 13 SV45-43 WF PRESSURE SV45-43 SPRINKLER WATER FLOW SWITCH - E260 5 2 3992735 POTTER PAD100 HEAT DETECTOR(1350 FIXED) <br /> L1:014 14 45-280 SMK NORTH 280 SMOKE DETECTOR NORTH - E261 6 3 3992720 POTTER PAD100 PULL STATION <br /> L1:015 15 45-280 SMK SOUTH 280 SMOKE DETECTOR SOUTH - E261 7 4 3992700 POTTER PAD100-MIM MINI INPUT MODULE <br /> _1:016 16 45-281 SMK NORTH 281 SMOKE DETECTOR NORTH - E261 8 2 SLA1104 POWERPATROL 12VDC 12 AH BATTERIES <br /> _1:017 17 45-281 SMK SOUTH 281 SMOKE DETECTOR SOUTH - E261 <br /> 9 2 BK-PC2RL SYSTEM SENSOR HORN/STROBES <br /> BUILDING FACP POINTS LISTLT10 2 BK-SCRL SYSTEM SENSOR STROBES <br /> 11 1 TG-7FS-A TELGUARD ATT CELLULAR DIALER <br /> SCALE: NONE ih E506 12 1 SSU00689 SPACEAGE FIRE ALARM STORAGE CABINET <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> HIS DESIGN AND/QR CHECKED <br /> FIRE ALARM SYSTEM DETAILS 27851053 A 04.28.23 <br /> NEW FIRE MONITORING PANEL REPLACEMENT 27851053 MDK TT 09.12.22 SPECIFICATION IS APPROVED SHEET <br /> BOE//VG® E506 <br /> A SHOP DRAWINGS AGOW/JS 04.28.23 APPROVED BY DEPT. DATE TITLE <br /> CHECKED <br /> et L n BUILDING 45-244 DB NG DMP NO. <br /> APPROVED <br /> .mE.amm�wmn=,�a <br /> APPROVED ELECTRICAL MASTER EVERETT, WA DWG NO. 45-244-E506 <br />
The URL can be used to link to this page
Your browser does not support the video tag.