LEGEND: <br /> JUNCTION BOX 4S UNLESS NOTED OTHERWISE <br /> OS IONIZATION SMOKE DETECTOR <br /> HEAT DETECTOR FIXED 135° <br /> ❑F MANUAL STATION, DOUBLE ACTING <br /> ® STROBE ALARM <br /> ®Q AUDIBLE/VISUAL ALARM <br /> ® FIRE ALARM PANEL <br /> 5 4 3 2 1 O ADT PANEL <br /> FAC CELLULAR COMMUNICATOR <br /> GENERAL NOTES <br /> 45-296 IS MONITORED BY 45-203 BUILDING FACP. <br /> l>BUILDING FA P <br /> FAC — — — — — -- — — — <br /> B REFERENCE DRWAWINGS <br /> HEA WOMEN RESTROOM MAN PULL R N1 SMK 0 FACP 45-296-1E60 POWER AND FIRE ALARM PLAII <br /> ZONE #: 05, L1:05 ZONE #: 07, L1:07 2 2 ZONE #: 01, L1:01 1/2"C 2#14 VIEW <br /> 4 F 3 S <br /> 15CD A 45-203—E506 FIRE ALARM DETAILS <br /> I <br /> 6 1/2"C 2#14 <br /> I CONSTRUCTION NOTES <br /> �1/2"C 2#14 SMK OFFICE W 30CD THIS FIRE ALARM DESIGN IS INTENDED TO BE A <br /> SMK OFFICE CENTER SMK OFFICE E PRELIMINARY DESIGN TO DIRECT A NICET CERTIFIED <br /> ZONE #: 02, L1:02 ZONE #: 03, L1:03 ZONE #: 04, L1:04 DESIGNER TO COMPLETE FINAL FIRE ALARM DESIGN IN <br /> HEAT MEN RE TROOM S 4 S 4 S 75CD ACCORDANCE WITH ALL APPLICABLE LAWS AND CODES. <br /> ZONE #: 06, L1:06 — — — — — _ _ _ APPLICATION FOR FIRE ALARM PERMIT USING FINAL <br /> 4 STAMPED DRAWINGS IS REQUIRED. <br /> Q <br /> 1/2"C 2#14 6 <br /> L/q\� REMOVE OLD FACP, FOCUS PANEL, AND ASSOCIATED <br /> 15CD HARDWARE. PROVIDE AND INSTALL NEW DIGITAL <br /> 6 ADDRESSABLE BUILDING FACP. PROVIDE PHENOLIC LABEL <br /> ON PANEL THAT READS: <br /> MAN PULL S1 MAN PULL R S2 <br /> ZONE #: 08, L1:08 ZONE #: 09, L1:09 "45-203 FIRE ALARM CONTROL PANEL <br /> 4 F 4 F EVF—FA-45-203 <br /> 120VAC FED FROM PANEL 'B'/11c" <br /> A PROVIDE CELLULAR COMMUNICATOR AND WIRE TO BUILDING <br /> FACP. SEE SHEET E506 FOR INSTALLATION DETAILS. <br /> INSTALL NEW SMOKE DETECTOR ABOVE FACP. <br /> ®REPLACE EXISTING FIRE ALARM DEVICE WITH NEW <br /> COMPATIBLE DEVICE. REUSE CONDUIT AND WIRE WHERE <br /> POSSIBLE. (TYP. 5 SMOKES, 3 MANUAL PULL STATIONS) <br /> ` FILL OUT AND RETURN ATTACHED BUILDING FACP <br /> POINTLIST TO ENGINEER A MINIMUM OF 3 WEEKS PRIOR <br /> TO FINAL ACCEPTANCE TESTING. <br /> ©PROVIDE NEW HORN/STROBE. NICET DESIGNER TO <br /> DETERMINE FINAL LOCATION AND QUANTITY AS REQUIRED <br /> BY CODE. <br /> SEE DRAWING 45-296-1E60 FOR 2 ADDITIONAL FIRE <br /> 1ST FLOOR FIRE ALARM PLAN ALARM POINTS. <br /> SCALE: 1/4"=1'—O" <br /> J <br /> A 4' 2' 0 2' 4' 8' <br /> SCALE: 1/4"=1'-0" <br /> � L � . <br /> SIM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> A FIRE PANEL REPLACEMENT 27851053 CSL MDK 08.05.22 THIS DESIGN AND/OR CHECKED 1ST FLOOR FIRE ALARM PLAN 27851053 A 08.05.22 <br /> SPECIFICATION IS APPROVED <br /> SHEET <br /> B SHOP DRAWINGS AGOW/JS 04.28.23 BOE//VG® m APPRovED BY DEPT. DATE TITLE HECKED 1 E260 m <br /> C <br /> �tL name° BUILDING 45-203 <br /> APPROVED JOB N0. COMP NO. <br /> 45-203-1 E260 3 <br /> APPROVED ELECTRICAL MASTER A/P STALL 102 EVERETT, WA DWI NO. 45-203-1E260 <br />