LEGEND: <br /> 0 <br /> SO IONIZATION SMOKE DETECTOR <br /> O HEAT DETECTOR FIXED 135' <br /> ❑F MANUAL STATION, DOUBLE ACTING <br /> ® STROBE ALARM <br /> ®Q AUDIBLE/VISUAL ALARM <br /> ® FIRE ALARM PANEL <br /> D ADT PANEL <br /> FAC CELLULAR COMMUNICATOR <br /> REFERENCE DRWAWINGS <br /> 45-745 HEAT R.R. W <br /> 112"r— 2#14 ZONE #:05, L1:05 1�45-239-1 E60 POWER AND FIRE ALARM PLAN <br /> SCD VIEW <br /> 2�45-239-E506 FIRE ALARM DETAILS <br /> i 4 ❑ �� <br /> MAN PULL DR S1 6 45-745 MAN PULL DR W <br /> ZONE #:03, L1:03 z <br /> ONE #:128, L1:07 CONSTRUCTION NOTES <br /> F® i <br /> 4 F THIS FIRE ALARM DESIGN IS INTENDED TO BE A <br /> 0 PRELIMINARY DESIGN TO DIRECT A NICET CERTIFIED <br /> DESIGNER TO COMPLETE FINAL FIRE ALARM DESIGN IN <br /> 75CD ACCORDANCE WITH ALL APPLICABLE LAWS AND CODES. <br /> SMK 0QFSF SMK OFFICE N 6 _ APPLICATION FOR FIRE ALARM PERMIT USING FINAL <br /> o ZONE 502, L1:02 0 ZONE 501, L1:01 /2"C 2#1 4 1/2"C 2#1 4 ❑ STAMPED DRAWINGS IS REQUIRED. <br /> ❑ o <br /> � � 45-745 HEAT R.R. E a ❑REMOVE OLD FACP, FOCUS PANEL, AND ASSOCIATED <br /> 2 2 u ZONE #:06, L1:06 HARDWARE. PROVIDE AND INSTALL NEW DIGITAL <br /> BUILDING FACP m Oa ADDRESSABLE BUILDING FACP. PROVIDE PHENOLIC LABEL <br /> ON PANEL THAT READS: <br /> 4 O� "45-239 FIRE ALARM CONTROL PANEL <br /> F 4 EVT-FA-45-239 <br /> FOCUS PANEL 120VAC FED FROM PANEL 'A'/12b" <br /> MAN PULL DR S2 4 F <br /> ZONE #:04, L1:04 O ❑PROVIDE CELLUAR COMMUNICATOR AND WIRE TO BUILDING <br /> FACP. SEE SHEET E506 FOR INSTALLATION DETAILS. <br /> 3OCD 45-745 MAN PULL DR JE <br /> 6 ZONE #:08, L1:08 ❑NOT USED. <br /> BUILDING 45-239 BUILDING 45-745 ❑REPLACE EXISTING FIRE ALARM DEVICE WITH NEW <br /> COMPATIBLE DEVICE. REUSE CONDUIT AND WIRE WHERE <br /> POSSIBLE. (TYP. 4 SMOKES, 4 MANUAL PULL STATIONS) <br /> FILL OUT AND RETURN ATTACHED BUILDING FACP <br /> POINTLIST TO ENGINEER A MINIMUM OF 3 WEEKS PRIOR <br /> TO FINAL ACCEPTANCE TESTING. <br /> ❑PROVIDE NEW HORN/STROBE. NICET DESIGNER TO <br /> A DETERMINE FINAL LOCATION AND QUANTITY AS REQUIRED <br /> BY CODE. <br /> CREW SHELTER POWER AND SIGNAL PLANKI <br /> 1 1 SCALE: 1/4"=1'-0" 4' <br /> 4' 2' 0 2' 4' 8' <br /> hm <br /> 0' �� SCALE: 1/4"=V-0" <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE CREW SHELTER CURRENT REVISION SYMBOL DATE m <br /> HIS DESIGN AND/OR CHECKED FIRE ALARM PLAN 27851053 A 04.28.23 <br /> NEW FIRE PANEL REPLACEMENT 27851053 CSL MDK 09.09.22 SPECIFICATION IS APPROVED <br /> A SHOP DRAWINGS AGOW/JS 04.28.23 BOE�/VG® m naPRovEo BY DEPT. DATE TITLE _ SHEET 1 E260 m <br /> CHECKED <br /> ete Linamen APPROVED BUILDING 45-239 JOB N0. COMP NO. <br /> xicrrum�u�x�me..„u,x 3 <br /> APPROVED ELECTRICAL MASTER EVERETT, WA DWI No. 45-239-1E260 <br />