Laserfiche WebLink
&41,IPi. <br /> A&RSOLAR <br /> PV Electrical Calculations 3211 Martin Luther King Jr Way S. <br /> Seattle,WA 98144(206)707-9937 <br /> Watts Output # of OCPD Total AC Comb. EGC <br /> Inverter Specs Ac voltage Array Specs (Adjusted for Temperature) <br /> (W) Inverters Branch out.(A) OCPD (AC <br /> Enphase IQ8M-72-M-US 325 1.3S 240 26 20 Inverter Enphase IQ8M-72-M-US Enphase IQ8M-72-M-US ****N/A**** <br /> ****N/A**** 0 0.00 0 0 0 35.1 50 #10 Mppt Input 1 2 3 1 2 3 1 2 3 <br /> ****N/A**** 0 0.00 0 0 0 Amperage (Imp) 9.61 0.00 0.00 9.61 0.00 0.00 0.00 0.00 0.00 <br /> Wa tts EGC THIS DRAWING CONSTITUTES THE <br /> Module Specs IMP Vmp Voc Isc Temp. Coef V(oc) DC Voltage (Vmp) 38.9 0.0 0.0 38.9 0.0 0.0 0.0 0.0 0.0 CONFIDENTIAL INFORMATION OF A&R SOLAR <br /> AND ITS RECEPTOR.POSSESSION DOES NOT <br /> CONFER ANY RIGHT IN OR LICENSE TO USE IT <br /> OR THE INFORMATION DISCLOSED HEREIN <br /> REC410AA Pure 410 9.61 42.7 49 10.35 Max Voltage(DC) 52.8 0.0 0.0 52.8 0.0 0.0 0.0 0.0 0.0 NOR ANYRIGHTTOREPRODUCE THIS <br /> 0.24 #10 DRAWING OR ANY PART HEREIN WITHOUT <br /> Temp. Adjusted 38.9 52.8 Max Amps (DC) 10.35 0.00 1 0.00 1 10.35 1 0.00 0.00 0.00 0.00 0.00 THEWRITTEN CONSENT OF A&R SOLAR. <br /> Optimizer? ***select*** Max Array Power(STC): 10.66 kW DC <br /> Equipment Enphase IQ8M-72-M-US Enphase IQ8M-72-M-US ****N/A**** Max Continuous AC Power: 8.45kW AC <br /> Mppt I nput 1 1 2 3 1 2 3 1 2 3 <br /> Module REC410AA Pure REC410AA Pure ****SELECT**** U <br /> # Modules per String 1 0 0 1 0 0 0 0 0 Interconnection Calcs Site Conditions V1 Q <br /> # Strings 1 0 0 1 0 0 0 0 0 Main Breaker 200 ASHRAESite: Seattle 00 <br /> # of Mods per group 1 0 0 1 0 0 0 0 0 Bus Bar 200 Low Temp(°F) 19 m Ln C" N <br /> o <br /> m ° 00, <br /> #of Mods/inverter 1 1 0 Max PV OCD Allowed 40 High 2%Temp (°F) 84 M L- o <br /> CO Q <br /> # of I nverters 10 16 0 PV OCPD Device Used 50 High 0.4%Temp(°F) 91N ro <br /> Total # of Modules 26 Tap or Breaker? Tap V Q LD ^ C0 a-+ <br /> C: to <br /> o o L <br /> Distance Wire (QTY) Phase Neutral Neutral EGC Min. 90°C Temp Fill Derated 75°C Current Operating Voltage 0 U > <br /> Ref. Conductor Description ft AL CU Gau e Conductors AWG QTv AWG wire Type Conduit Type Conduit Rating Correct. Derate Am acit Rating 125% Volta e Dro L W <br /> A Longest Branch to Jbox 50 Cu #12 2 N/A N/A #6 QCable AIR N/A 30 1 100% 30.00 25 16.9 240 1.11% o <br /> B Jbox to Combiner 50 Cu #10 6 N/A N/A #10 THWN-2 EMT 0.75" 40 1 80% 32.00 35 16.9 240 0.70% <br /> C Combiner to Disconnect 10 Cu #8 2 #8 1 #10 THWN-2 EMT 0.75" 55 1 100% 55.00 50 43.9 240 0.23% <br /> D Disco. to Interconnect 10 Cu #6 2 #6 1 #6 THWN-2 PVC 1" 75 1 100% 75.00 65 43.9 240 0.14% <br /> E <br /> F REVISIONS <br /> Rev. #: Date: <br /> G <br /> H <br /> I <br /> J <br /> K Voltage drop 0.00% �C Voltage drop 2.18% Total Voltage Drop: 2.18% Designed by: Thomas N <br /> Project Manager: <br /> Arthur Eith <br /> (612) 298-1795 <br /> Current Date:Sep 29, 2023 <br /> E2 Electrical <br /> Calculations <br />