Envelope Leakage Test <br />Testing Company: <br />Technician: <br />Name: <br />Name: <br />Address: <br />Credentials: <br />Email: <br />Building Information: Customer Information: <br />Project ID: <br />Lot 61-963219th C Name: <br />Address: <br />Address: <br />Geo-Tag Data: <br />Latitude: 47.909390 <br />Longitude:-122.207379 <br />Timestamp: 2023-07-0514:44:22 <br />Measured Leakage: <br />1.98 ACH50 <br />Leakage Target: <br />3.00 ACH50 <br />Compliance with Leakage Target: Pass <br />Test ID: <br />1 <br />Purpose of Test: <br />Las Vegas Multi Point <br />Measured CFM50: <br />440.7 (+/-1.7%) <br />Effective Leakage Area: 24.8 in' <br />Building Volume: <br />13,370.0 fN <br />Enclosure Surface Area: 0.0 ft' <br />Coefficient(C): <br />35.8 (+/- 7.3%) <br />Exponent(n): 0.641 (+/- 0.021) <br />Correlation Coefficient: <br />0.99984 <br />Test Standard: <br />RESNET 380 Multi -Point <br />Test Mode: Depressurize <br />Test Characteristics+ <br />Indoor Temp: 74 OF <br />Outdoor Temp: 80 OF <br />Altitude: 408.0 ft <br />Time Average Period: 10 seconds <br />Test Date and Time: <br />2023-07-0514*45*00 <br />500 <br />Depressurize <br />E 400 <br />L <br />a 300 <br />a 200 <br />80 <br />4 5 6 7 B 910 20 30 40 50 6070 <br />Building Pressure (Pa) <br />