14, <br />Painted Heads- Where sprinklers or cover plates on concealed sprinklers have <br />❑ ❑ ❑ <br />been painted by other than the sprinkler manufacturer, they shall be replaced. <br />15. <br />Listings- Escutcheons used with recessed, flush -type, or concealed sprinklers shall <br />❑ ❑ ❑ <br />be part of a listed sprinkler assembly and be metallic or shall be listed for use <br />around a sprinkler. No caulking or glue shall be used to seal penetrations or to <br />affix the components of a recessed escutcheon or concealed cover plate. <br />16. <br />Spare Sprinkler Cabinet- Spare Sprinkler cabinet, sprinkler wrench, and spare <br />❑ ❑ ❑ <br />sprinklers shall be provided. The stack of spare sprinklers shall include all types <br />and ratings installed and shall be as follows: <br />• Facilities having under 300 sprinklers— no fewer than six sprinklers <br />• Facilities having 300 to 1000 sprinklers— no fewer than 12 sprinklers <br />• Facilities having over 1000 sprinklers— no fewer than 24 sprinklers <br />(Where dry sprinklers of different lengths are installed, spare dry sprinklers shall <br />not be required, provided that a means of returning the system to service is <br />furnished.( <br />17, <br />Sprinkler Ust- A list of the sprinklers installed in the property shall be posted in <br />❑ ❑ ❑ <br />the spare sprinkler cabinet. The list shall include the following: <br />• Sprinkler Identification Number (SIN) if equipped; or the manufacturer, <br />model, orifice, deflector type, thermal sensitivity, and pressure rating <br />• General description <br />• Quantity of each type to be contained in the cabinet <br />• Issue or revision date of the list <br />18. <br />Sprinkler Guards -Sprinklers subject to mechanical injury shall be protected with <br />❑ ❑ ❑ <br />listed guards. <br />Fire Department Conne[tian (II <br />PASS FAIL N/A <br />19. <br />Assessable/Orientated - The FDC shall be assessable and arranged/orientated so <br />El ❑ ❑ <br />that a hose line can be attached to the inlets without interference. <br />20, <br />Clear Space- A clear working space not less than 36 Inches in width, 36 inches in <br />El ❑ ❑ <br />depth and 78 inches in height shall be provided. <br />21. <br />Knox Caps- Fire department connections shall be equipped with approved Knox <br />El ❑ ❑ <br />plugs/caps. <br />22. <br />Signs- Verify that a sign complying with the following has been provided: <br />El ❑ ❑ <br />• Metal sign with raised letters not less than 1 inch in sized. <br />• Signs shall read AUTOMATIC SPRI N KLERS or STANCH RES or TEST <br />CONNECTION or combination thereof as applicable. <br />• Where the FOC does not serve the entire buildin& a sign shall be provided <br />Indicating the portions of the building served. (Address, Location, Zone...) <br />Fire Marshal's Office 1 425 257 61 DO I everettwa.gov/fire I INFORMATION HANDOUT C-6 14.13.2020 1 Page 10 <br />