My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-24 2024-02-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-24
>
3003 W CASINO RD BLDG 40-24 2024-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 8:51:27 AM
Creation date
12/20/2023 6:48:30 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-24
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A <br /> *SPRINKLER VALVE WATERFLOW ALARM LEGEND <br /> MONITORING AND WATERFLOW ISOLATION <br /> TO SPRINKLERS SUPERVISION EQUIPMENT INSTALLATION, SEE SHEET EOA FOR SYMBOLS AND ABBREVIATIONS. <br /> LOW <br /> PRESSURE SWITCH A g <br /> WITH BUILT-IN <br /> RETARD/DELAY, I 5 <br /> POTTER #WFSR-F GENERAL NOTES <br /> (ALARM) I 12"X12" PHONE J-BOX <br /> 1 I FACP EVT-FA-40-24 FOR PRIMARY AND 1. ELECTRICAL CONTRACTOR SHALL INSTALL ENCLOSURE(S) AND <br /> (BY FIRE ALARM VENDOR) SECONDARY PHONE PRIMARY CONNECTION:Q POWER. <br /> LINE JACKS PHONE LINE TO <br /> (BY ELECTRICAL TELEPHONE 2. WET RISER/PIPING CONFIGURATION SHOWN IS DIAGRAMMATIC <br /> F_ <br /> CONTRACTOR) BACKBOARD/ DEMARC. AND DOES NOT NECESSARILY REPRESENT ANY SPECIFIC <br /> L- I TO WATER (CABLING BY BOEING INSTALLATION. <br /> WATER PRESSURE GAUGE J MOTOR GONG �_S r - - - SECONDARY CONNECTION: <br /> (SYSTEM PRESSURE) <br /> ALARM LINE g WATERFLOW PHONE LINE TO TELEPHONE <br /> ISOLATION ISOLATION I BACKBOARD/DEMARC. (CABLING <br /> (OPEN) VALVE, TAMPER SWITCH, BY BOEING IT) <br /> APOLLO POTTER #RBVS <br /> BY-PASS LINE #94A-103-27 (SUPERVISORY) FIRE ALARM SYSTEM COMMUNICATIONS DETAIL r2--'\ <br /> SCALE: NONE <br /> CHECK VALVE f O RETARD REFERENCE DRAWINGS <br /> CHAMBER <br /> WATER PRESSURE GAUGE CHECK DRAIN <br /> VALVE <br /> (SUPPLY PRESSURE) OPEN <br /> ® (CLOSED) <br /> L A <br /> - - - J <br /> OS&Y TAMPER <br /> SWITCH WATER BY-PASS TEST <br /> (SUPERVISORY) VALVE (CLOSED) STRAINER DRIP FIRE ALARM ANALOG PHONE LINE (PRIMARY) CONSTRUCTION NOTES <br /> - - - - <br /> CUP CONTROL * 1. ALL WIRING SHALL BE DRESSED AND TRAINED IN A <br /> LII PANEL DE ARC WORKMANLIKE MANNER. <br /> (FACP) MONITORED BY TYCO AND <br /> SIGNAL SENT TO CENTRAL 2. ALL WIRES SHALL BE LABELED WITH WIRE ID. <br /> BOEING FIRE DEPARTMENT <br /> OS&Y VALVE ANALOG PHONE LINE (SECONDARY). 3. ALL INCOMING POWER WIRING SHALL BE IN CONDUIT. <br /> CONTROL (OPEN) FIRE ALARM CABLING 4. ALL PENETRATIONS TO FIRE ALARM CONTROL PANEL <br /> CHECKVALVE S SMOKE DETECTOR, *TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY AND TELECOMMUNICATIONS ENCLOSURES SHALL BE IN <br /> PULL STATION, WATER CODE, AS SHOWN. ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br /> FLOW & TAMPER <br /> SWITCHES *BOEING SERVICES REQUEST MUST BE MADE �PROVIDE PHENOLIC LABELS, INSTALL AND CENTER ON <br /> DRAIN REQUESTING: TWO ANALOG VOICE (BUSINESS FLAT LINE) UPPER ENCLOSURE DOOR WITH FACP AND POWER <br /> HORNS, BELLS JACK/CONNECTIONS. AFTER JACKS ARE INSTALLED, CIRCUIT IDENTIFICATIONS. LABELS SHALL HAVE WHITE <br /> WATER SUPPLY PIPE & STROBES ANALOG LINES MUST BE REQUESTED TO CONNECT LETTERING AND RED BACKGROUND. <br /> ANALOG VOICE JACKS. <br /> *NOTE: ©CONFIGURE FIRE ALARM CONTROL PANEL TO <br /> LIMIT OF ONE (1) ISOLATION TRANSMIT PRIMARY AND SECONDARY COMMUNICATIONS <br /> VALVE ON ALARM SENSING LINE. IN A SIMULTANEOUS MANNER IN ACCORDANCE WITH <br /> SPRINKLER RISER WATERFLOW PRESSURE SWITCH W/DELAY DETAIL '�l FIRE ALARM SYSTEM SIGNAL AND COMMUNICATIONS OVERVIEW rTl� NFPA72-2016 26.6.4.1.4(B)(7). <br /> SCALE: NONE SCALE: NONE �PROVIDE CONDUIT WITH PULLSTRING. <br /> v BE�PROVIDE LINE SIZE BALL VALVE WITH LOCKABLE <br /> HANDLE, TYPE AS NOTED, ON ALARM LINE UPSTREAM <br /> OF ALARM SWITCH. FIELD VERIFY CORRECT SIZE. <br /> PROVIDE TAMPER SWITCH, TYPE AS NOTED, ON <br /> ISOLATION VALVE AS SHOWN. <br /> PROVIDE WATERFLOW PRESSURE SWITCH WITH <br /> ADJUSTABLE DELAY, TYPE AS NOTED. <br /> 11. CONFIRM ONLY ONE (1) ISOLATION VALVE IS <br /> INSTALLED ON WATERFLOW SENSING LINE. WHERE <br /> EXISTING INSTALLATIONS HAVE MORE THAN ONE (1) <br /> VALVE, COORDINATE REMOVAL OF ADDITIONAL <br /> VALVE(S) WITH BOEING CONSTRUCTION MANAGER. <br /> 12. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> INSTALLATION OF DEVICES AND PIPING MODIFICATIONS. <br /> PO ROX 1138 <br /> AUBURN,WA 98071 <br /> ( SEATRONICS 253-939-6060 <br /> FIRE PROTECTION EERVIGE$JW NO, <br /> 111065 111065-E506-15 <br /> DRAWNSUERRLE CURRENT REVISION SYMBOL GATE <br /> ACCEPTABILITY <br /> DEESSIGNN A D OR CH 5.13.19 FIRE ALARM SYSTEM DETAILS 1 t 1065-o A 5.13.19 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE <br /> A EVERETT FIRE PANEL REPLACEMENT SEA 5.13.19 <br /> SPECIFICATION IS APPROVED �� SHEET E506-15 <br /> BOE//VG® APPROVED BY DEPT. DATE EVERETT FIRE PANEL REPLACEMENT <br /> CHECAPPROVED NE BUILDING 40-024 JOB N0, 111065 COMP NO. <br /> APPROVED ELECTRICAL MASTER EVERETT, WA, DWG NO. 40-024-E506-15 / <br />
The URL can be used to link to this page
Your browser does not support the video tag.