My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-33 2024-02-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-33
>
3003 W CASINO RD BLDG 40-33 2024-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 9:18:58 AM
Creation date
12/20/2023 9:26:58 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-33
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT -- COMMENTS - GRID/SHEET LOC. <br /> L1:025 / 138 SV33-1 WF PRFSSURF 1F269 FIRE ALARM ABBREVIATIONS* LEGEND <br /> _1:024 / 13F SV33-1 WF ISO TAMPER 1E269 SEE SHEET E0A FOR SYMBOLS AND ABBREVIATIONS. <br /> _1:026 / 1.3C SV33-1 TAMPER TNE260 (40-24) ALT SECONDARY OR ALTERNATE ELEVATOR RECALL <br /> _1:028 / 13E SV33-3 WF PRESSURE 1E269 BEAM DET BEAM DETECTOR <br /> _1:027 / 13D SV33-3 WF ISO TAMPER 1E269 CDR COMPUTER/NETWORK/DATA/IDF ROOM <br /> L1:029 / 140 SV33-3 TAMPER TNE260 (40-24) COL COLUMN <br /> COMM FAIL COMMUNICATION FAILURE <br /> 11:031 / 142 SV33-5 W( PRLSSURE 1E270 CTRL CONTROL <br /> 11:030 / 141 SV33-5 WF ISO TAMPER 1E270 CW CATWALK <br /> L1:032 / 43 SV33-5 TAMPER TNE261 (40-24) DMPR DAMPER <br /> _1:034 / 145 SV33-7 WF PRESSURE 1E270 DIESEL DIESELDID DUCT <br /> SMOKE DETECTOR <br /> _1:033 / 144 SV33-7 WF ISO TAMPER 1E270 FP FIRE PUMP <br /> _1:035 / 146 SV33-7 TAMPER TNE261 (40-24) ELEC ELECTRICAL; ELECTRICAL ROOM <br /> L1:037 / 148 SV33-9 WF PRESSURE 1E271 ELEV ELEVATOR <br /> 147 SV33-9 WF ISO TAMPER 1E269 FAC EPPEXCESS PRESSURE PUMP <br /> _1:036 <br /> / FACP FIRE ALARM CONTROL PANEL <br /> _1:039 / 14F SV33-9 TAMPER TNE262 (40-24) ELEV FF HAT LIGHT FIRE FIGHTER HAT LIGHT IN A ELEVATOR <br /> _1:041 / 14C SV33-11 WF PRESSURE lF271 FLR FLOOR <br /> _1:040 / 14B SV33-11 WF ISO TAMPER 1E271 HE FIRE MAN VALVE <br /> AT TOR <br /> L1:042 / 140 SV33-11 TAMPER TNE262 (40-2%; <br /> NTDEV NTERFA EECDEVICE, MONITORING OR CONTROL GENERAL NOTES <br /> _1:044 / 150 SV33-13 WF PRESSURE 1E271 ISO ISOLATION VALVE KITCHEN KITCHEN 1. ALL INFORMATION ON THIS SHEET PRIOR TO EVERETT <br /> L1:043 / 4E SV33-13 WF ISO TAMPER 1E271 L BATT LOW BATTERY SITE HVAC REPLACEMENT HVAC-6 PROJECT WAS MOVED <br /> _1:045 / 151 SV33-13 TAMPER TNE262 (40-24) L FUEL LOW FUEL (FIRE PUMP DIESEL TANK IS BELOW 50% FILLED) TO SHEET E511. <br /> _1:001 / 122 MAN PULL Q FACP 1E266 LBY LOBBY <br /> 1.1:002 / 123 SMK @ FACP 1E266 LRD LOW RATE DISCHARGE <br /> MANUAL PULL <br /> L1:003 / 124 SMK 3RD FLR H.5-12 JE264 MANHPULL MECHANICAL ROOM STATION <br /> _1:004 / 125 SMK 3RD FLR H.5-12.5 3E264 NAC NOTIFICATION APPLIANCE CIRCUIT OR POWER SUPPLY <br /> L1:005 / 126 SMK 3RD FLR H.5--12.75 3E264 OS&Y OUTSIDE SCREW AND YOKE VAVLE <br /> _1:016132 SMK 3RD FLR H.5-13 3E265 - SMK FOR DOOR HOLDER OPERATION P PRESSURE TYPE <br /> / PD PUMP DISCHARGE VALVE; PRESSURE TYPE W/DELAY <br /> L1:006 / 127 SMK 3RD FLR H.5-13.5 3E265 PH PENTHOUSE <br /> L1:007 / 128 SMK 3RD FLR H.5-14 3E265 PIV POST INDICATOR VALVE <br /> POWER FAIL FACP POWER FAILURE <br /> 008 / 29 SMK 3RD FLR H-14 3E265 PREACT PREACTION SYSTEM <br /> L1:009 / 121` SMK 3RD FLR H-14.5 3E265 PRI PRIMARY REFERENCE DRAWINGS <br /> _1:010 / 125 SMK 3RD FLR H.5-14.75 3E265 PS PUMP SUPPLY VALVE <br /> 1-1:011 / 12C SMK 3RD FLR H.5-15.25 3E266 PWR POWER <br /> RF ROOF <br /> _1:012 / 12D SMK 3RD FLR H.5-15.7 3E266 RLY RELAY <br /> _1:013 j 12E SMK 3RD FLR H.5-16 3E265 SEC SECTION VALVE <br /> _1:014 / 130 SMK 3RD FLR H.5-16.5 3E266 SHUNT SHUNT TRIP <br /> L1:015 / 131 SMK 3RD FLR H.5-16.8 3E266 <br /> SMK SMOKE DETECTOR <br /> L1:046 - NPUT RLY 3RD FLR H.5 13 3E265 - RELAY FOR DOOR HOLDER OPERATION STL STALL <br /> _1:017 / 133 ELEV 18 FA 1E27C STROBE STROBE, HORN OR ANY NOTIFICATION DEVICE <br /> SUPPR SUPPRESSION <br /> _1:018 134 ELEV 18 TRBL 1E270 SUPV SUPERVISORY <br /> _1:019 135 UNIMODE RADIO RM FA 4E265 SV SPRINKLER VALVE <br /> _1:020 / 136 UNIMODE RADIO RM TRBL 4E265 TAMPER TAMPER SWITCH <br /> TL300 TL300 TYCO COMMUNICATION DEVICE <br /> L1:021 / 137 UNIMODE RADIO RM SUPV 4E265 TRBL TROUBLE <br /> L1:022 / 138 CFRBERUS SERVER RM FA 4E264 UV UNIT VALVE <br /> _1:023 / 139 CFRBERUS SERVER RM TRBL 4E264 VLV VALVE <br /> WF WATERFLOW SWITCH <br /> ZN ZONE <br /> *FOR POINTS LIST DESCRIPTORS A <br /> TYCO AND FACP POINTS LIST CONSTRUCTION NOTES <br /> SCALE: NONE E506 � UPDATED BATTERY CALCULATIONS BASED UPON <br /> PROPOSED DESIGN. <br /> ARIES NETLINK POWER SUPPLY AND BATTERY SIZE CALCULATION - 40-33 BUILDING <br /> TOTAL STAND-BY CURRENT PER SYSTEM: 0,277 AMPS To -,E.;T ADDRESSABLE DEVICE <br /> TOTAL ALARM CURRENT PER SYSTEM: 0.4252 AMPS 120VAC POWER CKT. <br /> ENTER STAND-BY HOURS: 48 HOURS XE2V32-10113.5%1 <br /> ENTER ALARM TIME: 10 MINUTES (H) (IU <br /> AMPERE HOUR REQUIRED: 13.39 AH <br /> TOTAL AMP HOUR REQUIRE(DERATING FACTOR 7.2): 17.00 AH Ai I:`IPI IT MODI II I- TYPICAL DPDT RELAY <br /> BATTERY SIZE REQUIRED PER SYSTEM(TWO(2)BATTERIES REQUIRED): 17 AH LI II <br /> 2-TIERED MAIN OR EXPANSION ENCLOSURE,MAX.20 AMPS- <br /> 15 AMPS O L PIC <br /> EXPANSION ENCLOSURE(S) REQUIRED? YES <br /> _ NUMBER OF ENCLOSURE MAIN EXPANSION REQUIRED: DH <br /> NUMBER OF POWER MANAGEMENT UNIT(PMU) BOARD REQUIRED: 1 (L d 23U 3`I U 6 <br /> NUMBER OF POWER SUPPLY UNIT(PSU) REQUIRED: 7 n IJO N DH <br /> TOTAL TOTAL ADDRES',ALILE CIRCUIT FROM FACP <br /> ITEM STANDBY STANDBY ALARM ALARM <br /> NO DESCRIPTION QTY (AMPS) (AMPS) c (AMPS) DOOR H OLDE R INPUT MODULE <br /> 7 MCB(WITH KEYBOARD/DISPLAY) 1 0.15830 0.15830 0.3000.3000 0 0.30000 <br /> 2 DIGITAL ALARM COMMUNICATOR TRANSMITTER(DACT) EXPANSION CARD 1 0.02400 0.08950 0.03700 0.03700 AND R E LAY WIRING DIAGRAM <br /> 3 SMARTONE PHOTOELECTRIC SMOKE DETECTOR DS-PS 15 0.00015 0.00225 0.00022 0.00330 , <br /> 4 SMARTONE CONTACT INPUT MODULE(AI'S,N/O) 43 0.00058 0.02494 0.00058 0.02494 SCALE: NONE E5`06 <br /> 5 POWER MANAGEMENT UNIT(PMU) BOARD#I, MAX. 10.8 AMPS 1 1 1 0.07000 0.07000 0.09000 0.09000 <br /> TOTALS 0.277 0.452 <br /> A FIRE ALARM CONTROL PANEL BATTERY CALCULATIONS-M ISSUE FOR CONSTRUCTION <br /> SCALE: NONE E506 TGOT%4 <br /> APRIL 24, 2019 <br /> SYM RkVISION BY APPROVED DOTE SYM REVISION BY APPROVED GATE <br /> ACCEPTABILITY ZD 02.22.1$DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> EVERETT SITE HVAC REPLACEMENT HVAC-6-RECORD 19081703 SAZAN/ZO 02.22.18 THIS DESIGN AND/OR FIRE ALARM DETAILS B 08.16.19 <br /> CATI <br /> (// \ SPECIFION IS APPROVED ZO 02.22.18 _ SHEET <br /> ENGINEER <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/LF 04.24.19W/HG - '[ �_�O` a m APPROVED BY DEPT. DATE CK 02.22.18 TITLEEVERETTFIRE PANEL REPLACEMENT CHECKED E506 <br /> B EVERETT FIRE PANEL REPLACEMENT AGO08.16.19 BUILDING 40-033 <br /> PETE LINAMEN JOB N0. COMP N0. <br /> APPROVED f„n,. ELECTRICAL MASTER EVERETT, WA. M NO, 40-33-E506 <br />
The URL can be used to link to this page
Your browser does not support the video tag.