3003 W CASINO RD BLDG 40-33 2024-02-09
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-33
>
3003 W CASINO RD BLDG 40-33 2024-02-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2024 9:18:58 AM
Creation date
12/20/2023 9:26:58 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-33
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
*SPRINKLER VALVE WATERFLOW ALARM 6 LEGEND <br /> MONITORING AND WATERFLOW ISOLATION <br /> TO SPRINKLERS SUPERVISION EQUIPMENT INSTALLATION 5 SEE TO SHEET EOA FOR SYMBOLS AND ABBREVIATIONS. <br /> F_ WATERFLOW <br /> PRESSURE <br /> UBUILTW SWITCH <br /> 12 OX <br /> I FACP EVT-FA-40-33 FOR PRIMARY AND <br /> WITH <br /> RETARD/DELAY, I (BY FIRE ALARM VENDOR) SECONDARY PHONE PRIMARY CONNECTION:Q <br /> POTTER #WFSR-F LINE JACKS PHLINE ONE <br /> TO GENERAL NOTES <br /> (ALARM) I (BY ELECTRICAL BACKBOARD DEMARC. 1. ELECTRICAL CONTRACTOR SHALL INSTALL ENCLOSURE(S) <br /> 1 I n CONTRACTOR) (CABLING BY BOEING AND POWER. <br /> V IT) 2. WET RISER/PIPING CONFIGURATION SHOWN IS <br /> SECONDARY CONNECTION:Q DIAGRAMMATIC AND DOES NOT NECESSARILY REPRESENT <br /> F_ J PHONE LINE TO TELEPHONE <br /> ANY SPECIFIC INSTALLATION. <br /> TO WATER BACKBOARD/DEMARC. <br /> MOTOR GONG (CABLING BY BOEING IT) <br /> WATER PRESSURE GAUGE J <br /> (SYSTEM PRESSURE) ALARM LINE 9 WATERFLOW FIRE ALARM SYSTEM COMMUNICATIONS DETAIL r2-'� _ <br /> I ISOLATION ISOLATION I SCALE: NONE E506-1 <br /> (OPEN) VALVE, TAMPER SWITCH, <br /> APOLLO POTTER #RBVS <br /> BY-PASS LINE <br /> #94A-103-27 (SUPERVISORY)) <br /> L — — -- <br /> 'TEM '� -IJEHCE OF OPERATION <br /> CHECK VALVEf RETARD REFERENCE DRAWINGS <br /> ° CHAMBER 1. ALARM CC11'JDITII)N <br /> I DRAIN <br /> WATER PRESSURE GAUGE CHECK <br /> VALVE 1 1 A(.'TIVATICIIi I)F AI.I f ALARM '-,HALL CALI;E THE FOLLOWING <br /> (SUPPLY PRESSURE) OPEN I (CLOSED) 1 <br /> L — �— — � a Alarn��l h`Idlcator LEG on FACP {�� I Ilunlnate. - <br /> F.ACF Infernal S,:,under to artivtlte. <br /> OS&Y TAMPER _ . DI Plcv I:-rc1I'eIr message on FACP to JiSploy ALARM FOII`IT LOCATION INIFORMATION, <br /> SWITCH WATER BY-PASS TESTd Activ-:lte FACP DACT. transrnrf ALAF'M signal to Central -,tatlon rnonbrincl company. <br /> (SUPERVISORY) VALVE (CLOSED) STRAINER DRIP CONSTRUCTION NOTES <br /> 'UPER✓ISORI IDITICIII 1. ALL WIRING SHALL BE DRESSED AND TRAINED IN A <br /> CUP _ r r;. <br /> ilii <br /> ^_ I ACTIVATIOIJ C,F At11 SIIFERVI':OF'i :HALL CAUSE THE F!:rLUJWIPJG, WORKMANLIKE MANNER. <br /> a SLIPervlSory irdIc�:Icor LED on FACP to illomIrlate. 2. ALL WIRES SHALL BE LABELED WITH WIRE ID. <br /> I:. FAC:F Irlt?rrn:Il ``:,cLn?d?r to actrdtlt? 3. ALL INCOMING POWER WIRING SHALL BE IN CONDUIT. <br /> OS&Y VALVE c Drsplav proper message on FACP to rhsl:rloy SUPEF'VIS0Rr POINT LOCATIOI'J INFORMATION. <br /> CONTROL (OPEN) d ktivate FA1:'P DACT, transmit SIJPER'VISOP'i sic_Inal to Central Station monitoring company. 4. ALL PENETRATIONS TO FIRE ALARM CONTROL PANEL AND <br /> CHECK TELECOMMUNICATIONS ENCLOSURES SHALL BE IN <br /> VALVE3 TP.OUELE i;01IDiT1011: ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br /> 1 <br /> PROVIDE PHENOLIC LABELS, INSTALL AND CENTER ON AI TIVATIOIJ OF AH[' TF'i)IIELE COIJDITIOI,I '-,HALL CAUSE THE F'.LLOWING'. UPPER ENCLOSURE DOOR WITH FACP AND POWER <br /> DRAIN a. Trouble indi,ortor LED on FACP to IIhurnmate. CIRCUIT IDENTIFICATIONS. LABELS SHALL HAVE WHITE <br /> WATER SUPPLY PIPE b, FACP Internal SDui)LJer to activate LETTERING AND RED BACKGROUND. <br /> Display Proper message on FACP to display TROUBLE COPJDITION © CONFIGURE FIRE ALARM CONTROL PANEL TO TRANSMIT <br /> *NOTE: d Afivcte FACP DACT, transmit TROUBLE slgnol to !ventral Station monitoring company. PRIMARY AND SECONDARY COMMUNICATIONS IN A <br /> LIMIT OF ONE (1) ISOLATION <br /> VALVE ON ALARM SENSING LINE. SIMULTANEOUS MANNER IN ACCORDANCE WITH <br /> NFPA72-2016 26.6.4.1.4(6)(7). <br /> SPRINKLER RISER WATERFLOW PRESSURE SWITCH W/DELAY DETAIL r PROVIDE CONDUIT WITH PULLSTRING. <br /> SCALE: NONE E506-1 <br /> FIRE ALARM SYSTEM SEQUENCE OF OPERATION PROVIDE LINE SIZE BALL VALVE WITH LOCKABLE HANDLE, <br /> TYPE AS NOTED, ON ALARM LINE UPSTREAM OF ALARM <br /> SCALE: NONE E506-1 SWITCH. FIELD VERIFY CORRECT SIZE. <br /> PROVIDE TAMPER SWITCH, TYPE AS NOTED, ON ISOLATION <br /> VALVE AS SHOWN. <br /> BILL OF MATERIALS B>- PROVIDE WATERFLOW PRESSURE SWITCH WITH <br /> -- - ----- ADJUSTABLE DELAY, TYPE AS NOTED. <br /> - - - Part# Item Description_ _ Unit _ Qty- <br /> 11. CONFIRM ONLY ONE (1) ISOLATION VALVE IS INSTALLED <br /> FIRE ALARM ANALOG PHONE LINE (PRIMARY) 76-800100-001 ARIES NETLink Multi-Loop Control Unit ea 1 ON WATERFLOW SENSING LINE. WHERE EXISTING <br /> CONTROL PANEL "--"""""""" -- -- - - <br /> Backplane PCB for ARIES NETLink Multi-Loop INSTALLATIONS HAVE MORE THAN ONE (1) VALVE, <br /> (FACP) <br /> *TELCO I 76-800010-002 Control unit _ ea 1 COORDINATE REMOVAL OF ADDITIONAL VALVE(S) WITH <br /> DEMARC MONITORED BY TYCO AND Expansion Card Cage for ARIES NETLink Multi-Loop BOEING CONSTRUCTION MANAGER. <br /> SIGNAL SENT TO CENTRAL 76-800010-001 Control unit ea 1 <br /> BOEING FIRE DEPARTMENT -- ------ - - ------ ------ 12. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> ANALOG PHONE LINE (SECONDARY) 76-800015-001 ARIES NETLink Multi-Loop DACT Card ea 1 INSTALLATION OF DEVICES AND PIPING MODIFICATIONS. <br /> FIRE ALARM CABLING 84-330002-001 PULL STATION-ADDRESSABLE ea 1 <br /> ISMOKE DETECTOR, *TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY DS-PS PHOTO DETECTOR ea 15 <br /> PULL STATION, WATER CODE,AS SHOWN. -- ---- --- <br /> FLOW & TAMPER DS-SB STANDARD BASE FOR DS SERIES DETECTORS ea 1 <br /> ---- — <br /> SWITCHES *BOEING SERVICES REQUEST MUST BE MADE 70-407018-001 Al MODULE N/0-W/0 SILICONE ea 51 <br /> REQUESTING: TWO ANALOG VOICE (BUSINESS FLAT .. ___.--.-...-..-_. dAt HORNS BELLS UNE) JACK/CONNECTIONS. AFTER JACKS ARE SLA1116 12V 18AH Battery ea 2 <br /> & STROBES INSTALLED, ANALOG LINES MUST BE REQUESTED TO — -- - <br /> CONNECT ANALOG VOICE JACKS. 1000015.0000 SSU-00500-BATTERY CABINET ea 1 <br /> 06-SS000689-1 RECORD STORAGE CABINET ea 1 <br /> FIRE ALARM SYSTEM SIGNAL AND COMMUNICATIONS OVERVIEW ./�3 FIRE ALARM SYSTEM BILL OF MATERIALS ISSUE FOR CONSTRUCTION <br /> SCALE: NONE E506-1 <br /> SCALE: NONE E50APRIL 24, 2019 �� 2 <br /> � 6 1 <br /> 0 N DATE <br /> SUBTITLE CURRENT REVISION SYMBOL <br /> DATE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY TK 04.24.19 c <br /> THIS DESIGN AND/OR OH KO - FIRE ALARM SYSTEM DETAILS <br /> EVERE'T FIRE PANEL REPLACEMENT W2640474 SAZAN/TK 04.24.19 _ ,( SPECIFICATION IS APPROVED ZO 04.24.19 SHEET <br /> ........._ ...._.._ ._.._ _ /�/\ c 1 <br /> A EVERETT FIRE PANEL REPLACEMENT AGOW/WC 06.16.19 APPROVED BY DEPT. GATE CK ___ 0_4.24.19 TITLE EVERETT FIRE PANEL REPLACEMENT E506- 1 <br /> CHECKED <br /> PETE LINAMEN DK 04.24.19 JOB N0. .COMP N0. ~ <br /> G �. n A DYED BUILDING 40-033 W2640474 <br /> AR-------- <br /> OVED ELECTRICAL MASTER EVERETT, WA. OWC NO. 40-033-E506-1 <br />