Laserfiche WebLink
REQUIRED NUMB ' •• 6 . ATION OF MODEL REQUIRED NUMBER AND LOCATION OF MODEL <br /> • 1100'V" 'IES BRACES FO' 4/12&5/12 1100"V" SERIES BRACES FOR 6/12&7/12 <br /> SINGLE SECTION / DOUBLE WIDES TRIPLE WIDES SINGLE SECTION DOUBLE WIDES TRIPLE WIRES <br /> crimmommille <br /> —i I I- -i 1 L L'' :iri : I. L. El 3-- -E 1 L L 1 i-1- - -E I it. <br /> SINGLE SECTION .•UBLE WIRES ALL WIDTHS DOUBLE WIRES ALL WIDTHS SINGLE SECTION DOUBLE WIDES ALL WIDTHS DOUBLE WIDES ALL WIDTHS <br /> ALL WIDTHS •to 76' upto76' ALL WIDTHS upto76' upto76' <br /> up to 76' up to 76' <br /> LEGEND: (Length of house is actual box size) <br /> 1.- :'C' - Approximate location of the system(See note H) <br /> 2.-+- - Location of ASF Model 1100"V' (Lateral and Longitudinal Bracing)or 1100 T(Lateral only) <br /> 3.-0- - Location of additional ASF Model 1100 T"V'System(Lateral only)for homes exceeding 76'in length or with roof pitch between 4.37/12(20 degrees) <br /> and 5/12,the additional system is to be installed at approximately the midpoint of the house and may be installed at either exterior beam. <br /> 4.- ® - Installation of single wide homes require two(2)anchors per side located not more than ten(10)feet from each end(with a minimum of 3150 load rating) <br /> 5.- - Location of additional ASF Model 1100 T"V'System(Lateral only)for homes exceeding 76'in length,sidewall height exeeding 96"or with roof pitch <br /> between 6/12&7/12 the additional system is to be installed at approximately the midpoint of the house and may be installed at either exterior beam. <br /> NOTE: <br /> a) Installation of the longitudinal system eliminates the need for the longitudinal anchors. <br /> b) Installation of the transverse system eliminates the need for all anchors,diagonal frame ties and stabilization plates exc ept when noted. <br /> (Legend#5& note C) <br /> c) All other home manufacturer's instructions for installation of stabilizing devices must be followed, including installation of vertical tie-down <br /> anchors,and mating line column, shear wall or center-line tie-down anchors. NOTE WIND ZONE II: ALL VERTICAL ANCHORS (NOT TO <br /> EXCEED 8'SPACING) MUST BE INSTALLED PER MANUFACTURER's INSTALLATION INSTRUCTIONS! <br /> d) If the home manufacturer's installation instructions are not available,the home must be Installed in accordance with any state promulgated <br /> rules or as required by the authority having jurisdiction. <br /> e) If bolts, nuts and tech screws are lost,they may be replaced as long as they meet or exceed the specs for OTI ASFS hardware. <br /> f) When the length of home exceeds 76,sidewall height exceeds 96'or the roof pitch Is between 437/12(20 degrees)and 5/12,add 1 transverse system <br /> (see location diagrams above)6/12:a total of 4 Transverse&3 Longitudinal systems are needed&7/12:a total of 5 Tra nsverse&3 Longitudinal systems <br /> are needed. (Longitudinal portion only required when longitudinal bracing Is required by home manufacturer). <br /> g) An alternative method using the 1100 CVD anchors(dry set)or 1100 CVW(wet set)may be used on a footing size of 16'dlam eter X 24"depth. These <br /> brackets are designed for lateral and longitudinal protection. <br /> h) It is recommended that the systems be installed at the 2nd pier In from each end of the house. However,they may be Insta lied at any location at least <br /> 2 feet,but not more than 14 the house length,In from the ends of the home. <br /> STATE OF MICHIGAN ONLY: As required by Section 1805 2 of the 200 Michigan Building Code. the depth of the footer shall be a minimum depth of <br /> 42 inches below grade, except that the authority having jurisdiction may approve a lesser depth based on known prevailing soil and weather <br /> conditions.or as provided by the exception under Section 1805 2 1 of the Code <br /> STATE OF ALABAMA ONLY: Maximum pier height is limited to 32"with pier defined <br /> in the Alabama Regulation as"that portion of the support system between the top of <br /> the footing and the bottom of the pier cap' !�1m <br /> The State of Alabama limits the use of this <br /> system to H U.D labeled homes <br /> STATE OF NORTH CAROLINA ONLY: I <br /> Tubing must be galvanized and,when I-Transverse Arm,I-Beam Connector <br /> the manufacturer's installation <br /> instructions are not available, <br /> vertical wall tie-downs must be <br /> installed not to exceed 8-feet <br /> on center (Wind Zone II) - - <br /> STATE OF IDAHO ONLY. F- "V"Brace I-Beam <br /> Concrete must be a i� Connectors <br /> of 8"in depth j "'1 H-Transverse Arm /minimum <br /> Top(1.25") <br /> Bottom(1.5") <br /> fret-••••°.— <br /> • '., TECHNOLOGIES INC. i ;(! <br /> 40 <br /> D-Pan Transverse Connector E-"V"Brace Tube <br /> Phone:(800)284-7437 or D(W)or D(D)Concrete (1.51 <br /> Transverse Connector t <br /> Fax:(931)796-8811 . <br /> ollvertechnologles.com IO <br /> 467 Swan Avenue,Hohenwald,TN 38462 B-Ground Pan or441111111lMik J- Pan V Bracket or <br /> C-Concrete Base(le / J(W)or J(D)Concrete <br /> footer,runner,etc.) <br /> -'---..V"Bracket <br /> pavl•nrl ni/17/111'n PATFNT it AA141 CO and nthar natantc rk.nriinn (g/;71.\ Dane 1/1 <br />