My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
DISH Wireless L.L.C. 12/11/2023
>
Contracts
>
Agreement
>
Other Agreements
>
DISH Wireless L.L.C. 12/11/2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/22/2023 3:11:18 PM
Creation date
12/22/2023 3:09:45 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
DISH Wireless L.L.C.
Approval Date
12/11/2023
Council Approval Date
11/29/2023
End Date
12/11/2033
Department
Real Property
Department Project Manager
Darcie Byrd
Subject / Project Title
Communications Site Lease Agreement
Tracking Number
0004102
Total Compensation
$464,563.00
Contract Type
Agreement
Contract Subtype
Other Agreements
Retention Period
6 Years Then Destroy
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GROUNDING NOTES: <br /> 1. ALL GROUND ELECTRODE SYSTEMS(INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S)SHALL • <br /> BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. r <br /> 2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTIAL RESISTANCE CO EARTH TESTING(PER IEEE 1100 AND 81) FOR <br /> sh <br /> GROUND ELECTRODE SYSTEMS,THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO <br /> ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. <br /> 3 THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO wireless <br /> PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. <br /> 5701 SOUTH SANTA FE DRIVE <br /> 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY LITTLETON,Co 80120 <br /> BONDING ACROSS THE DISCONTINUITY WITH#6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. <br /> 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS <br /> WITH GREEN INSULATION,SIZED IN ACCORDANCE WITH THE NEC,SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS <br /> EQUIPMENT. <br /> 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL <br /> EQUIPMENT GROUND WIRES.#6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. <br /> 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE 1 <br /> OF THE GROUND BUS ARE PERMITTED. CAMP+ <br /> B. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE#2 SOLID TINNED ASSOCIATES <br /> COPPER UNLESS OTHERWISE INDICATED. <br /> 19515 N.CREEK PNWV.SUITE 220 <br /> 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. BOTHELLwA98011 <br /> PHONE.14251240,4392 <br /> 10. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY www.CAMPASSOC.COM <br /> SUPPORTED. <br /> 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. <br /> 12. ALL GROUND CONNECTIONS ABOVE GRADE(INTERIOR AND EXTERIOR)SHALL BE FORMED USING HIGH PRESS CRIMPS. <br /> 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. <br /> 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND OP' a <br /> BAR. a t •, <br /> 15. APPROVED ANTIOXIDANT COATINGS('i.e.CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND • <br /> CONNECTIONS. {O44 <br /> ' <br /> 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. <br /> sd foss <br /> 17. MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES,FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND <br /> RING, IN ACCORDANCE WITH THE NEC. <br /> 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH(1) #2 BARE SOLID TINNED COPPER GROUND <br /> CONDUCTOR <br /> 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED o< TO ALTER THIS DOCUMENT. EER' <br /> THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR,SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR <br /> SLEEVES THROUGH WALLS OR FLOORS.WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL DRAWN BY: CHECKED BY:APPROVED BY: <br /> CONDITIONS,NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED.WHERE USE OF METAL CONDUIT IS UNAVOIDABLE(i.e., JAC JAC JAG <br /> NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE)THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. <br /> 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE#2 BARE SOLID TINNED COPPER IN 3/4" REDS REV X: --- <br /> NON-METALLIC, FLEXIBLE CONDUIT FROM 24"BELOW GRADE TO WITHIN 3"TO 6"OF CAD-WELD TERMINATION POINT.THE EXPOSED END <br /> OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). CONSTRUCTION <br /> 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE,THE CONTRACTOR SHALL ROUTE DOCUMENTS <br /> TWO GROUNDING CONDUCTORS FROM THE ROOFTOP.TOWERS,AND WATER TOWERS GROUNDING RING,TO THE EXISTING GROUNDING <br /> SYSTEM,THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO SUBMITTALS <br /> THE EXISTING GROUNDING SYSTEM,THE BUILDING STEEL COLUMNS. LIGHTNING PROTECTION SYSTEM,AND BUILDING MAIN WATER LINE REV DATE DESCRIPTION <br /> (FERROUS OR NONFERROUS METAL PIPING ONLY). DO NOT ATTACH GROUNDING TO FIRE SPRINKLER SYSTEM PIPES. A 10/10/2022 ELECTRICAL RDISONS <br /> n 10/24/2022 ISSUED FOR EWA <br /> 11/07/2022 ISSUED FOR PERMS <br /> 2/14/2023 COMMENTS mow THE cm <br /> 0/18/2023 REVISED EOMPMERr LOCATION <br /> A-9/22/2023 RUED FOR FINAL <br /> A R/n/2m ISSUED FOR PR, <br /> AkE3 PROJECT NUMBER <br /> SESEA00377C <br /> DISH Wireless L.L.C. <br /> PROJECT INFORMATION <br /> SESEA00377C <br /> 2930 WETMORE AVENUE <br /> EVERETT, WA 98201 <br /> SHEET TITLE <br /> GENERAL NOTES <br /> SHEET NUMBER <br /> GN-4 <br /> DISH Wireless L.L.C.TEMPLATE KRSION 4S-10/29/2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.