MODULE SPECIFICATIONS QCelIs Q.PEAK DUO BLK ML-G10+395 DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS
<br /> RATED POWER(STC) 395 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG.HIGH TEMP MICROI NVERTER TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 13.3 A AC
<br /> MODULE VOC 45.3 V DC STATE Washington JUNCTION BOX(1) MAX.CURRENT(ISC X1.25)= 16.6 A AC BLUE RAVEN
<br /> MODULE VMP 36.9 V DC CITY Everett CONDUCTOR(TC-ER,COPPER(90'C))= 12 AWG
<br /> MODULE IMP 10.7 A DC WEATHER STATION SNOHOMISH CO CONDUCTOR RATING= 30 A
<br /> MODULE ISC 11.1 A DC ASHRAE EXTREME LOW TEMP('C) -5 AMB.TEMP.AMP.CORRECTION= 1 1403 N. Research Way
<br /> VOC CORRECTION -0.27 %/'C ASHRAE 2%AVG.HIGH TEMP('C) 30 ADJUSTED AMP.= 30 > 16.6 Orem, UT48 0097
<br /> VMP CORRECTION -0.34 %/'C JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 13.3 A AC WWW.BLUERAVENSOLAR.COM
<br /> SERIES FUSE RATING 20 A DC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 CIR 5 CIR 6 JUNCTION BOX(2) MAX.CURRENT(ISC X1.25)= 16.6 A AC CONFIDENTIAL-THE INFORMATION
<br /> ADJ, MODULE VOC @ ASHRAE LOW TEMP 48.9 V DC NUMBER OF MODULES PER MPPT 11 CONDUCTOR(UF-B, COPPER(60-C))= 10 AWG HEREIN CONTAINED SHALL NOT BE
<br /> USED FOR THE BENEFIT OF ANYONE
<br /> ADJ. MODULE VMP @ ASHRAE 2%AVG. HIGH TEMP 32.2 V DC DC POWER RATI NG PER Cl RCUIT(STC) 4345CONDUCTOR RATING= 30 A EXCEPT BLUE RAVEN SOLAR NOR
<br /> - -------- -- SHALL IT BE DISCLOSED IN WHOLE OR
<br /> TOTAL MODULE NUMBER 11 CONDUIT FILL DERATE= 1 IN PART TO OTHERS OUTSIDE
<br /> MICROINVERTER SPECIFICATIONS Enphase IQ8+Microinverters STC RATING OF ARRAY 4345 AMB.TEMP.AMP.CORRECTION= 1 RECIPIENTS ORGANIZATION,EXCEPT
<br /> p IN CONNECTION WITH THE SALE AND
<br /> POWER POINT TRACKING(MPPT)MIN/MAX 30 S8 V DC AC CURRENT @MAX POWER POINT(IMP 13,3 ADJUSTED AMP.= 30 > 16.6 USE OF THE RESPECTIVE EQUIPMENT,
<br /> WITHOUT THE WRITTEN PERMISSION
<br /> MAXIMUM INPUT VOLTAGE 60 V DC MAX.CURRENT(IMP X 1.25) 16.6375 JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 13.3 A AC OF BLUE RAVEN SOLAR LLC.
<br /> MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 COMBINER BOX(3) MAX.CURRENT(ISC X1.25)= 16.6 A AC
<br /> MAXIMUM USABLE DC INPUT POWER 440 W MAX.COMB.ARRAY AC CURRENT(IMP) 13.3 CONDUCTOR(UF-B,COPPER(60-C))= 10 AWG NABCEP
<br /> MAXIMUM OUTPUT CURRENT 1.21 A AC MAX.ARRAY AC POWER 319OW AC CONDUCTOR RATING= 30 A
<br /> AC OVERCURRENT PROTECTION 20A CONDUITFILL DERATE= 1 CERTIFIED
<br /> MAXIMUM OUTPUT POWER 290 W AC VOLTAGE RISE CALCULATIONS DIST(FT) COND. JRISE(V) VEND(V) %VRISE AMB.TEMP.AMP.CORRECTION = 1 PV INSTALLATION
<br /> CEC WEIGHTED EFFICIENCY 97 % VRISE SEC. 1(MICRO TO 180X) 39.6 12 Cu. 1.76 241.76 0.73% ADJUSTED AMP.= 30 > 16.6 PROFESSIONAL
<br /> VRISE SEC, 2()BOX TO COMBINER BOX) 35 lOCu, 1.18 241.18 0.49% COMBINER BOX TO INVERTER RATED AMPS= 13.3 A AC Scott Gurney
<br /> AC PHOTOVOLATIC MODULE MARKING(NEC 690.52) VRISE SEC.3(COMBINER BOX TO POI) 5 10 Cu. 0.17 240.17 0.07% MAIN PV OCPD(15) MAX.CURRENT(RATED AMPS X1.25)= 16.64 A AC #PV-011719-015866
<br /> NOMINAL OPERATING AC VOLTAGE 240 V AC TOTAL VRISE 3.11 243.11 1.30% CONDUCTOR(THWN-2,COPPER(75-C TERM.))= 10 AWG CONTRACTOR:
<br /> NOMINAL OPERATING AC FREQUENCY 47-68 HZ AC CONDUCTOR RATING= 35 A BRS FIELD OPS
<br /> MAXIMUM AC POWER 240 VA AC PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC 690.54) CONDUIT FILL DERATE= 1 800-377-4480
<br /> MAXIMUM AC CURRENT 1.0 A AC AC OUTPUT CURRENT 13.3 A AC AMB.TEMP.AMP.CORRECTION= 1
<br /> MAXIMUM OCPD RATING FOR AC MODULE 20 A AC NOMINAL AC VOLTAGE 240 V AC ADJUSTED AMP. = 35 > 16.6
<br /> U U
<br /> GROUNDING NOTES WIRING &CONDUIT NOTES ''
<br /> Q �
<br /> Z
<br /> 1.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690.47]AND[NEC 250.50-60]SHALL BE 1.ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE 0 Y
<br /> PROVIDED. PER[NEC 690.47],THE GROUNDING ELECTRODE SYSTEM OF AN EXISTING BUILDING MAY BE APPLICATIONS. CO Y �
<br /> USED AND BE BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR(USEQ .
<br /> N
<br /> INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE POLARIS BLOCK OR NEUTRAL BAR). CC 00
<br /> 04
<br /> USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 3.ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS DISALLOWED ABOVE G O M
<br /> 2.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN LIVE PARTS,MEYERS HUBS RECOMMENDED C:
<br /> THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER) IF SMALLER THAN#6 AWG COPPER WIRE 4.UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF Q 0 W W
<br /> PER [NEC 250.64(B)]. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SURFACE IN ACCORDANCE WITH[NEC 110.2,110.3(A-B)]. LL N N
<br /> SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER[NEC 250.64(C)]. 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH WITH ROOF SURFACE TO BE USED FOR WIRE
<br /> 3.GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN 8 AWG AND NO GREATER THAN 6 AWG MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. Z Z
<br /> COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR CABLE LISTED AND L
<br /> 4.PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 250.122],AND ALL METAL IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT;ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS W 0 U) W W
<br /> PARTS OR MODULE FRAMES ACCORDING TO[NEC 690.461. REQUIRED. LUC Q
<br /> 5.MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC 690.42]. 7.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 690.8]FOR MULTIPLE G V
<br /> 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A CONDUCTORS.
<br /> MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 8.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8" O N ABOVE c
<br /> 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (B)(2)(A)], [NEC TABLEV) (n
<br /> MANUFACTURER'S INSTALLATION INSTRUCTIONS. 310.15(B)(3)(A)],&[NEC 510.15(13)(3)(C)]. 5 O 0
<br /> 8.ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN 9.EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90-C RATED,WET AND UV RESISTANT,AND UL = M O > V V
<br /> GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP U 0 CV W Q 0
<br /> 9.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVISES EDGES.
<br /> EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED,
<br /> 10.GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR STRANDED,AND BARE WHEN WET AND UV RESISTANT,RATED FOR 600V DRAWING BY:
<br /> EXPOSED. 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND
<br /> 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO [NEC 690.45] AND BE A MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. Jonah Sundrud
<br /> MINIMUM OF 10 AWG WHEN NOT EXPOSED TO DAMAGE (6 AWG SHALL BE USED WHEN EXPOSED TO 12.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION C
<br /> DAMAGE). 13.VOLTAGE DROP LIMITED TO T B FOR DC CIRCUITS AND 3%FOR ACIRCUITS NLw W Q 2023901
<br /> LOT DATE:
<br /> 12.GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR CODED GREEN(OR MARKED 14. NEGATIVE GROUNDED SYSSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DCGREEN IF 4 AWG OR LARGER). POSITIVE-RED(OR MARKED RED),DC NEGATIVE-GREY(OR MARKED GREY) WAS /111
<br /> 13.ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE 15.POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: P � • January 16, 2023
<br /> GROUNDED BUSHINGS AT BOTH ENDS. DC POSITIVE-GREY(OR MARKED GREY),DC NEGATIVE-BLACK(OR MARKED BLACK)
<br /> 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.661, DC SYSTEM GEC SIZED 16.AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE A OR L1-BLACK,PHASE B OR L2-RED, �Q' 0 PROJECT NUMBER:
<br /> ACCORDING TO[NEC 250.166],MINIMUM 8 AWG WHEN INSULATED,6 AWG WHEN EXPOSED TO DAMAGE. PHASE C OR L3-BLUE,NEUTRAL-WHITE/GRAY
<br /> 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND 'USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE y 6 9159 0
<br /> CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH[NEC 250.134]OR[NEC 250.136(A)] "USE-2 IS AVAILABLE AS UV WHITE
<br /> REGARDLESS OF VOLTAGE. 17.RIGID CONDUIT,IF INSTALLED,(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. 4 17 :39 : 1
<br /> 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, SHEET NAME:
<br /> FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH [NEC 690.31], [NEC 250.118(10)]. DISCONNECTING A
<br /> MEANS SHALL COMPLY WITH[NEC 690.13]AND[NEC 690.151. -4 54072 _Q �4 E L E C CALC S
<br /> 19.CONDUIT RAN THROUGH ATTIC WILL BE'A LEAST 18"BELOW ROOF SURFACE COMPLYING WITH[NEC Own �Gis- R� �� 07 ' 00 '
<br /> 230.6(4)]AND SECURED NO GREATER THAN 6'APART PER[NEC 330.30(8)]. `SSfONAL`��` REVISION: PAGE NUMBER: