STANDARD LABELS ADDITIONAL LABELS <br /> LABEL 1 LABEL 8 BLUE RAVEN <br /> WARNINGFOR PV SYSTEM DISCONNECTING MEANS WHERE THE O WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE <br /> LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE LOCATION OF ALL ELECTRIC POWER SOURCE <br /> ELECTRIC SHOCK HAZARD OPEN POSITION. MAIN DISTRIBUTION UTILITY DISCONNECT(S) DISCONNECTING MEANS ON OR IN THE PREMISES 1403 N. Research Way <br /> (2017 NEC 690.13(8)1 POWER TO THIS BUILDING IS ALSO SUPPLIED SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT Orem, UT 84097 <br /> TERMINALS ON THE LINE AND (2020 NEC 690.13(8)1 FROM A ROOF MOUNTED SOLAR ARRAY WITH LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> LOAD SIDES MAY BE ENERGIZED A RAPID SHUTDOWN DISCONNECTING MEANS DISCONNECT(S)FOR ALL ELECTRIC POWER 800.377.4480 <br /> IN THE OPEN POSITION GROUPED AND LABELED WITHIN LINE OF SITE PRODUCTION SOURCES CAPABLE OF BEING WWW.BLUERAVENSOLAR.COM <br /> AND 10 FT OF THIS LOCATION INTERCONNECTED. CONFIDENTIAL-THE INFORMATION <br /> [2017 NEC 705.10] HEREIN CONTAINED SHALL NOT BE <br /> [2020 NEC 705.10] USED FOR THE BENEFIT OF ANYONE <br /> LABEL 2 EXCEPT BLUE RAVEN SOLAR NOR <br /> PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT SHALL IT BE DISCLOSED IN WHOLE OR <br /> THE DISCONNECTING MEANS AS A POWER SOURCE LABEL 9 IN PART TO OTHERS OUTSIDE <br /> I ADISCONNECTI AND WITH THE RATED AC OUTPUT CURRENT AND THE ! WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE RECIPIENTS ORGANIZATION,EXCEPT <br /> NOMINAL OPERATING AC VOLTAGE. LOCATION OF ALL ELECTRIC POWER SOURCE IN CONNECTION WITH THE SALE AND <br /> (2017 NEC 690.54] USE OF THE RESPECTIVE EQUIPMENT, <br /> RATED AC OUTPUT CURRENT 13.31 A POWER TO THIS BUILDING IS ALSO DISCONNECTING MEANS ON OR IN THE PREMISES WITHOUT THE WRITTEN PERMISSION <br /> (2020 NEC 690.541 SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT OF BLUE RAVEN SOLAR LLC. <br /> NOMINAL OPERATING AC VOLTAGE 240 V SUPPLIED FROM MAIN DISTRIBUTION LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> UTILITY DISCONNECT LOCATED DISCONNECT(S)FOR ALL ELECTRIC POWER <br /> PRODUCTION SOURCES CAPABLE OF BEING <br /> LABEL 3 INTERCONNECTED. NABCEP <br /> 0 WARNING IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL [2017 NEC 705.10] <br /> [2020 NEC 705.10] CERTIFIED <br /> ANYWHERE THAT IS POWERED BY BOTH THE UTILITY <br /> DUAL POWER SUPPLY AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL <br /> AND SUBPANELS. PV INSTALLATION <br /> (2017 NEC 705.12(8)(3)] LABEL EN PROFESSIONAL <br /> SOURCES: UTILITY GRID AND (2020 NEC 705.12(8)(3)] ! WARN I N G PERMANENT PLAQUE DIRECTORY TO BE <br /> PV SOLAR ELECTRIC SYSTEM LOCATED AT MAIN SERVICE EQUIPMENT DENOTING Scott Gurney <br /> POWER TO THIS BUILDING IS ALSO SUPPLIED THE LOCATION OF THE RAPID SHUTDOWN SYSTEM #PV-011719-015866 <br /> FROM A ROOF MOUNTED SOLAR ARRAY.SOLAR DISCONNECTING MEANS IF SOLAR ARRAY RAPID <br /> SHUTDOWN DISCONNECTING SWITCH IS NOT CONTRACTOR: <br /> ARRAY RAPID SHUTDOWN DISCONNECT IS GROUPED AND WITHIN LINE OF SITE OF MAIN <br /> LABEL 4 BRS FIELD OPS <br /> 0 WARN I N G APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT LOCATED OUTSIDE NEXT TO THE UTILITY METER. SERVICE DISCONNECTING MEANS. <br /> TO THE BACK-FED BREAKER FROM THE POWER (2017 NEC 705.10 AND 690.56(C)(1)(a)] 800-377-4480 <br /> [2020 NEC 705.10 AND 690.56(C)] �� �� 202101 * 2 <br /> POWER SOURCE OUTPUT CONNECTION SOURCE. w�►$� <br /> DO NOT RELOCATE [2017 NEC 705.12(8)(2)(3)(b)] <br /> (2020 NEC 705.12(8)(3)(2)] <br /> THIS OVERCURRENT LABEL 11 Go <br /> DEVICE ! WARNING PERMANENT PLAQUE OR DIRECTORY TO BE .j. 7 :39 : U Q <br /> LOCATED AT AC COMBINER PANEL. Q <br /> PHOTOVOLTAIC SYSTEM [2020 NEC 110.21(8)] 4 1 <br /> OWARNING LABELS (2020 NEC 110.21(8)] _ _ <br /> APPLY TO THE PV COMBINER BOX COMBINER PANEL �� 54072 w4 O O "t <br /> (2017 NEC 705.12(B)(2)(3)(c)] . �J `� ' ' Q CV M <br /> DO NOT ADD LOADS �t+,� SIC .r�R O 0 0 > <br /> 9 <br /> (2020 NEC 705.12(8)(3)(3)] CC`, js'i v00 <br /> THIS EQUIPMENT FED BY MULTIPLE S► G N C: <br /> � M <br /> SOURCES.TOTAL RATING OF ALL 0NAL O Q O W W <br /> OVERCURRENT DEVICES,EXCLUDING Z a) N � <br /> MAIN SUPPLY OVERCURRENT SUBPANEL — — <br /> DEVICE,SHALL NOT EXCEED <br /> UTILITY MAIN IF INTERCONNECTION AC PV PV COMBINER — .— <br /> AMPACITY OF BUSBAR. METER SERVICE PANEL IS MADE HERE) DISCONNECT METER BOX W O W W <br /> � � H <br /> 00 00 00 00 0 Cl) 0 <br /> SOLAR PV SYSTEM EQUIPPED LABEL 6 H a� N <br /> BUILDINGS WITH PV SYSTEMS SHALL HAVE A N > O (1)WITH RAPID SHUTDOWN PERMANENT LABEL LOCATED AT EACH SERVICE O O O O O O O = co O > U V <br /> EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS (,� 0 CV w Q <br /> TURN RAPID SHUTDOWN ARE CONNECTED OR AT AN APPROVED READILY <br /> "O FI POSITION TO TO THE VISIBLE LOCATION AND SHALL INDICATE THE LOCATION O IF BREAKER O <br /> OR PLACARD 11 <br /> WN PV SYSTEM OF RAPID SHUTDOWN INITIATION DEVICES. IS USED DRAWING BY: <br /> SHUT DO <br /> 0 <br /> AND REDUCE (2017 NEC 690.56(C)(1)(a)] <br /> SHOCK HAZARD <br /> IN THE ARRAY [2020 NEC 690.56(0)] O OR 10 Jonah S u n d ru d <br /> OR PLACARD PLOT DATE: <br /> RAPID SHUTDOWN LABEL 7 January 16 2023 <br /> SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT <br /> SWITCH FOR SWITCH <br /> (2017 NEC 690.56(0)(3)] PROJECT NUMBER: <br /> SOLAR (2020 NEC 690.56(0)(2)] <br /> 691590 <br /> LABELING NOTES SHEET NAME: <br /> 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT LABELS <br /> REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL <br /> 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED <br /> 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: <br /> 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE 0 PV7 <br /> HANDWRITTEN[NEC 110.211 DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. <br />