Laserfiche WebLink
FLOOR PLAN <br />SCALE: 1/4" = V-0" <br />NEW HVAC LAYOUT PLAN <br />SCALE: 1/4" = V-0" <br />O DIFUSOR CIRCULAR <br />O AIR SUPPLY DUCTING <br />C, DOWNWARD ROUND DIFFUSER. SIZE <br />AIR RETURN DUCTING <br />ACCORDING TO CONNECTED DUCT SIZE <br />ELF SPIRAL DUCT <br />FURNACEANDCOIL <br />6,o INSULATED FLEXIBLE DUCT <br />REQUIRED MIN. VENTILATION <br />AREA <br />BREAHTING <br />BREATING <br />AREA VENT <br />EXHAUST <br />REQUIRED VENT <br />AREA&USE <br />(NET SF) <br />OCCUPANT <br />RATE (CFM) <br />RATE (CFM) <br />RATE <br />(CFM) <br />(CFM/SF) <br />DINING AREA <br />1103 <br />70/1000 <br />7.5 <br />0.18 <br />778 <br />SERVICE AREA <br />115 <br />82 <br />RESTROOM <br />94 <br />0.714 <br />67 <br />OFFICE SPACE <br />68 <br />5/1000 <br />5 <br />0.06 <br />100 <br />KITCHEN AND SERVICE AREA <br />455 <br />0.7 <br />318 <br />10%OF KITCHEN HOOD <br />-870 <br />EXHAUST IN KITCHEN <br />SUB -TOTAL <br />1 18351 <br />i <br />i <br />i <br />475 <br />WITH 0.8 EFFECTIVENESS <br />(IMC TABLE 403.1.2) <br />570 <br />OFAIVEIM <br />D E S I G N S T U D 1 0 <br />903121 STAVE. ,SW <br />SEATTLE,WA 98106 <br />TEL. 206.322.4323 <br />FAX. 206.322.9177 <br />E-MAIL:IN FO@CATCHSTUD IO. C OM <br />WWW.CATCHSTUDIO.COM <br />ENGINEER: <br />q� 4ses7 <br />r <br />cGIS <br />s�C1VAL E, <br />PROJECT TITLE <br />FRYING <br />LEMON FISH <br />2616 COLBY AVE EVERETT <br />WA 98201 <br />SHEET TITLE: <br />FLOOR PLAN <br />NEW HVAC LAYOUT PLAN <br />REVISIONS: <br />CATCH DESIGN STUDIO <br />DRAWN: NOS NARIN <br />CHECKED: <br />SCALE: AS NOTED <br />FILE: <br />DATE: 09/30/2021 <br />SHEET# <br />ma <br />