My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12815 19TH AVE SE 2024-02-14
>
Address Records
>
19TH AVE SE
>
12815
>
12815 19TH AVE SE 2024-02-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 11:30:11 AM
Creation date
1/2/2024 3:26:21 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12815
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br />SYMBOL <br />DESCRP110N <br />PIPE ELBOW DOM <br />PIPE B_BOW UP <br />I1�'F <br />FLANGE <br />FLEX CCNNECHCN <br />O <br />TEE OUTLET UP <br />.. <br />TEE OUTLET DOWN <br />R° <br />AUTOMATIC AIR VENT <br />--A • F <br />BALL VALVE <br />---0 <br />BALANONG VALVE <br />C'b <br />BUTTERFLY VALVE <br />CHECK VALVE <br />DEAN CUT <br />D4 <br />GATE VALVE <br />Cp <br />GLOBE VALVE <br />PPE SZE REDUCIICN <br />3 <br />PIPE CAP <br />DIRECTON OF FLOW <br />`r— <br />BREAK IN PIPE OR DUCT <br />11 <br />WALL CLEAN OUT <br />e <br />FLOOR CLEAN OUT <br />FLOOR DRAIN <br />n <br />FLOOR SNK <br />® <br />VENT THROUGH ROOF <br />CLEARANCE REQUIREMENT <br />WORK TO BE REMOVED <br />REMSION CLOUD <br />CO2 <br />CARBON DIOXIDE SENSOR <br />QS <br />SENSOR <br />QH <br />HUMIDISTAT <br />SWITCH <br />$T <br />TIMER SWITCH <br />XX OR XX <br />EQUIPMENT ITEM XX <br />SD=X <br />DIFFUSER TAG WITH <br />XXX <br />CFM AMOUNT <br />DUCT DIMENSION TAG: <br />X/Y <br />X PLAN OR HORIZONTAL DIMENSION, <br />Y ELEVATION OR VERTICAL DIMENSION <br />1 _ FLAG NOTE <br />REVISION NOTE <br />LINETYPES <br />LINE <br />DESCRIPTION <br />LINE, ARCH. BACKGROUND <br />LIGHT LINE, EXISTING <br />HEAVY LINE, NEW WORK <br />COLD WATER <br />- - <br />HOT WATER <br />HOT WATER CIRCULATION <br />�4 <br />WASTE <br />- --V- -- <br />VENT <br />—HWS— <br />HEATING WATER SUPPLY <br />- -HWR- - <br />HEATING WATER RETURN <br />—RWL— <br />RAINWATER LEADER <br />ORL <br />OVERFLOW RAINWATER LEADER <br />--RS-- <br />REFRIGERANT SUCTION <br />RL <br />REFRIGERANT LIQUID <br />C <br />CONDENSATE DRAIN <br />G <br />NATURAL GAS <br />F <br />FIRE PROTECTION WATER <br />CA <br />COMPRESSED AIR <br />THE GREENBUSCH GROUP, EYC <br />ABBREVIATIONS <br />NARRATIVE OF SCOPE <br />LEGEND <br />AC <br />AIR CONDITIONING <br />HW <br />HOT WATER <br />DEMOLITION <br />SYMBOL <br />DESCRIPTION <br />ARE <br />ABOVE FINISHED FLOOR <br />HWC <br />HOT WATER CIRCULATION <br />DEMOLISH AND REMOVE EXISTING BOILERS (2) AND SUPPORT EQUIPMENT/ PIPING; <br />X <br />DETAIL OR SECTION CALLCUT <br />ASHRAE <br />AMERICAN SOCIETY OF <br />HEATING, REFRIGERATION <br />HWR <br />HWS <br />HOT WATER RETURN <br />HOT WATER SUPPLY <br />PUMPS, AND PIPING SPECIAL EQUIPMENT. <br />XX <br />AND AIR CONDITIONING <br />ID <br />INDIRECT DRAIN, <br />MECHANICAL: <br />INSTALL NEW BOILERS ( PUMPS AND SUPPORT EQUIPMENT UTILIZING EXISTING BOILER <br />ENGINEERS <br />INSIDE DIAMETER <br />NECTIONS TO EXISTING BUILDING HYDRONIC SYSTEM. <br />ROOM AND POINT OF CONNECTIONS <br />SECTICN CUT LINE <br />SOD <br />BACKDRAFT DAMPER <br />IE <br />INVERT ELEVATION <br />REPLACE EXISTING 3-WAY TERMINAL UNIT VALVES WITH 2-WAY VALVES, TO ALLOW <br />BFF <br />BELOW FINISHED FLOOR <br />IN <br />INCH <br />FOR VARIABLE SPEED PUMPING. <br />BTUH <br />BRITISH THERMAL UNITS <br />KW <br />KILOWATT, (1000 WATTS) <br />PER <br />PER HOUR <br />LEAVING AIR TEMPERATURE <br />DEFERRED SUBMITTAL: <br />BACKDRAFT DAMPER <br />STRUCTURAL DETAILS AND CALCULATIONS FOR THE FLOOR MOUNTED BOILER(S) AND <br />CO <br />CEILING DIFFUSER <br />LWT <br />LEAVING WATER <br />PIPING SUPPORT EQUIPMENT IN ACCORDANCE WITH ASCE 7-10 SECTION 13.1.4 SHALL <br />OEM <br />CUBIC FEET PER MINUTE <br />TEMPERATURE <br />BE INCLUDED IN THE CONTRACTORS SCOPE OF WORK AND PROVIDED AS A DEFERRED <br />HIRE DAMPER <br />SUBMITTAL ONCE THE CONTRACTOR HAS BEEN SELECTED. <br />CIRC <br />CIRCULATING <br />MAX <br />MAXIMUM <br />CO <br />CLEAN OUT <br />MBH <br />1000 BTU PER HOUR <br />FIRE AND SMOKE DAMPER <br />COND <br />CONDENSATE <br />MCA <br />MINIMUM CIRCUIT AMPS <br />APPLICABLE CODES <br />COORD <br />COORDINATE <br />MFG <br />MANUFACTURER <br />VOLUME DAMPER, MANUAL <br />COTS <br />CLEAN OUT TO GRADE <br />MIN <br />MINIMUM <br />2018 INTERNATIONAL BUILDING CODE <br />CW <br />COLD WATER <br />MOD <br />MOTOR OPERATED DAMPER <br />2018 INTERNATIONAL MECHANICAL CODE <br />MOTO2 OP02ATED DAMPER <br />DEG <br />DEGREE <br />MTG <br />MOUNTING <br />2018 INTERNATIONAL FUEL GAS CODE <br />DIA <br />DIAMETER <br />NO <br />NORMALLY CLOSE <br />2018 INTERNATIONAL FIRE CODE <br />ON <br />DOWN <br />NIC <br />NOT IN CONTRACT <br />2020 NATIONAL ELECTRICAL CODE <br />DN <br />DUCT OFFSET DOM IN ROW DIRECTON <br />2018 WASHINGTON STATE AMENDMENTS TO ALL CODES <br />DWG <br />DRAWING <br />NFPA <br />NATIONAL FIRE PROTECTION <br />E <br />EXISTING <br />ASSOCIATION <br />CURRENT CITY OF EVERETT AMENDMENTS TO ALL WASHINGTON STATE CODES <br />UP <br />DUCT OFFSET UP IN ROW DIRECTION <br />EA <br />EACH, EXHAUST AIR <br />NO <br />NORMALLY OPEN <br />EVERETT MUNICIPAL CODE <br />E <br />ELEVATION <br />TUTS <br />NOT SCALE <br />DUCT WhIWT SOUND LINING <br />EATAT <br />ENTERING AIR TEMPERATURE <br />CA <br />OUTSIDE AIR <br />EG <br />EXHAUST GRILLE <br />OAT <br />OUTSIDE AIR TEMPERATURE <br />DUCT Whl INTERNAL ACOUSTICAL LINING <br />ESP <br />EXTERNAL STATIC PRESSURE <br />OgD <br />OPPOSED BLADE DAMPER <br />EWT <br />ENTERING WATER <br />OS&Y <br />OUTSIDE STEM AND YOLK <br />— _ — <br />SNGE LINE DUCT WTH INTERNAL LINING <br />TEMPERATURE <br />POC <br />POINT OF CONNECTION <br />DRAWING INDEX <br />EXIST <br />EXISTING <br />PSI <br />POUNDS PER SQUARE INCH <br />FLEXIBLE CONNECTION OR FLEXIBLE DUCT <br />EXH <br />EXHAUST <br />RA <br />RETURN AIR <br />F <br />FAHRENHEIT <br />RG <br />RETURN GRILLE <br />MO.1 MECHANICAL LEGEND, ABBREVIATIONS AND DRAWING INDEX <br />FLEXIBLE DUCT <br />FCO <br />FLOOR CLEANOUT <br />RPM <br />REVOLUTIONS PER MINUTE <br />MO.2 WA CODE NOTES <br />ED <br />FIRE DAMPER, FLOOR DRAIN <br />SA <br />SUPPLY AIR <br />MO.3 MECHANICAL SCHEDULES <br />TRANSITION - RECTANGULAR TO ROUND <br />FDC <br />FIRE DEPARTMENT <br />SO <br />SUPPLY DIFFUSER <br />MD1.1 BOILER ROOM PLUMBING DEMOLITION PLAN <br />Silver Lake Elementary <br />CONNECTION <br />SP <br />STATIC PRESSURE <br />MD1.2 BOILER ROOM HVAC DEMOLITION PLAN <br />FLA <br />FULL LOAD AMPS <br />Boiler Replacement <br />/ <br />99 ROUND ELBOW (RP OR R/W=1.5) <br />FOIC <br />FURNISHED BY OWNER, <br />SPD <br />SPEC <br />STATIC PRESSURE DROP <br />SPECIFICATIONS <br />M1.1 BOILER ROOM PLUMBING PLAN <br />M1.2 BOILER ROOM MECHANICAL PLAN <br />INSTALLED BY CONTRACTOR <br />TOP <br />TOTAL DYNAMIC HEAD <br />M2.1 BUILDING B AND C TERMINAL UNIT MECHANICAL PLAN <br />address: <br />FPM <br />FEET PER MINUTE <br />TPD <br />TOTAL PRESSURE DROP <br />M3.0 MECHANICAL SECTIONS <br />12815 Bothell -Everett Highway <br />FT <br />FOOT, FEET <br />TSP <br />TOTAL STATIC PRESSURE <br />MAO MECHANICAL DETAILS <br />G <br />NATURAL GAS <br />TYP <br />TYPICAL <br />Everett, WA 9820&46630 <br />WTH TURNING VANES <br />RECTANGULAR ELBOWV <br />GA <br />GAUGE <br />VOLT, VENT <br />GAL <br />GALLONS <br />VD <br />VOLUME DAMPER <br />GALV <br />GALVANIZED <br />VTR <br />VENT THRU ROOF <br />SUPPLY AIR DUCT UP <br />GPM <br />GALLONS PER HOUR <br />W <br />WASTE <br />GRD <br />GRILLES, REGISTERS, AND <br />WE <br />WET BULB TEMPERATURE <br />SUPPLY AIR DUCT DOWN <br />DIFFUSERS <br />W/ <br />WITH <br />OWE <br />GYPSUM WALL BOARD <br />WOO <br />WALL CLEAN OUT <br />SUPPLY DIFFUSER OR GRILLE <br />HP <br />HORSEPOWER <br />WHA <br />WATER HAMMER ARRESTER <br />HVAC <br />HEATING, VENTILATION AND <br />WSEC <br />WASHINGTON STATE <br />LINEAR DIFFUSER <br />AIR CONDITIONING <br />ENERGY CODE <br />SUPPLY AIR OUTLET, SIDEWALL <br />RETURN AIR DUCT UP <br />RETURN AIR DUCT DOWN <br />RETURN AIR GRILLE <br />design phase: <br />~eF <br />RETURN AIR INLET, SIDEWALL <br />PERMIT <br />EXHAUST DUCT DP <br />SET <br />EXHAUST DUCT DOWN <br />EXHAUST AIR GRILLE <br />feVISIOnS: <br />EXHAUST AIR OUTLET, SIDEWALL <br />no. description date <br />OR <br />THERMOSTAT <br />P¢oy WAS <br />A <br />GIST373 <br />_ <br />ZONAL �yGA ,1ti <br />design by: <br />R L / A V <br />drawn by: <br />J A / J Z <br />scale: <br />as noted <br />date: <br />11 /15/2022 <br />job no.: <br />2022.125 <br />MECHANICAL LEGEND, <br />ABBREVIATIONS AND <br />DRAWING INDEX <br />approvals: sheet number: <br />M0.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.