My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12815 19TH AVE SE 2024-02-14
>
Address Records
>
19TH AVE SE
>
12815
>
12815 19TH AVE SE 2024-02-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 11:30:11 AM
Creation date
1/2/2024 3:26:21 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12815
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 WASHINGTON STATE ENERGY CODE NOTES <br />1. PROVIDE RECORD DOCUMENTS IN ACCORDANCE WITH SECTION C103.6.1. PROVIDE OPERATION AND MAINTENANCE MANUALS IN ACCORDANCE WITH <br />SECTION C103.6.2. PROVIDE THE OWNER WITH THE COMPLIANCE DOCUMENTS REQUIRED BY SECTION C103.6.3. REFER ALSO TO THE PROJECT <br />SPECIFICATIONS FOR ALL CLOSEOUT AND RECORD DOCUMENT REQUIREMENTS. THE DRAWINGS SHALL INDICATE, AT A MINIMUM, THE LOCATION AND <br />PERFORMANCE DATA OF EQUIPMENT, AS -BUILT CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATE, <br />EQUIPMENT TAGS, AND FIELD VERIFIED DIMENSIONS. <br />2. PROVIDE OWNER TRAINING PER SECTION C103.6.4 AND AS REQUIRED BY THE PROJECT SPECIFICATIONS. OWNER TRAINING MUST TAKE PLACE BEFORE <br />OWNER OCCUPANCY BUT CAN TAKE PLACE AFTER SUBSTANTIAL COMPLETION HAS BEEN APPROVED. <br />3. SEAL, GASKET, OR WEATHER STRIP ALL ACCESS DOORS AND PANELS THAT OPEN FROM CONDITIONED SPACES TO UNCONDITIONED SPACES AND PER <br />SECTION C402.5.4. <br />4. PROVIDE VARIABLE SPEED DRIVES FOR ALL FAN AND PUMP MOTORS GREATER THAN OR EQUAL TO 7.5 HP PER SECTION C403.2.3. <br />5. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING CONDITIONS NOT LESS THAN THE VALUES INDICATED IN TABLE <br />C403.3.2(1)A THROUGH C403.3.2(12) OF THE WASHINGTON STATE ENERGY CODE AND AS INDICATED ON THE CONTRACT DOCUMENTS. <br />6. MECHANICAL SYSTEM EQUIPMENT SIZING COMPLIES WITH ENERGY CODE COMPLIANCE LIMITS SECTION C403.3.1. <br />7. PROVIDE EACH ZONE WITH THERMOSTATIC CONTROLS PER SECTION C403.4, AS REQUIRED BY THE PLANS, SPECIFICATIONS, AND TO FULFILL THE <br />SEQUENCE OF OPERATIONS. <br />8. PROVIDE DEAD BAND BETWEEN HEATING/COOLING SPACE SENSOR SETPOINTS OF 5 DEGREES AS REQUIRED BY SECTION C403.4.1.2 OR AS DESCRIBED <br />IN THE TEMPERATURE CONTROL SEQUENCES. PROVIDE LIMIT SWITCHES PER SECTION C403.4.1.3. PROVIDE OFF HOUR CONTROLS (SETBACK, AUTOMATIC <br />START/STOP, OFF HOUR SCHEDULING, ETC.) PER SECTION C403.4.2. <br />9. SIMULTANEOUS HEATING AND COOLING TO INDIVIDUAL ZONES SHALL BE PROHIBITED AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES <br />EXCEPT AS PERMITTED BY THE WASHINGTON STATE ENERGY CODE AND APPROVED BY THE BUILDING OFFICIAL. <br />10. PROVIDE RELAYS AND CONTROLS CAPABLE OF DISABLING THE HEATING/COOLING, OR RESETTING THE ZONE TEMPERATURES, PER SECTION C403.4.1.6 <br />WHERE AN OPERABLE DOOR OPEN FROM A CONDITIONED SPACE TO THE OUTDOORS. <br />11. THE HVAC SYSTEM AND ITS CONTROLS SHALL ALLOW ECONOMIZER OPERATION AS THE FIRST STAGE OF COOLING WHENEVER MECHANICAL COOLING IS <br />REQUIRED. AIR AND WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS <br />REQUIRED TO MEET THE REMAINDER OF THE COOLING LOAD. REFER TO CONTROL SEQUENCES FOR MORE INFORMATION. <br />12. INSULATE PIPE PER THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS AND PER SECTION C403.10.3 AND PER TABLE C403.10.3. <br />TABLE C403.10.3 - MINIMUM PIPE <br />INSULATION <br />THICKNESS (INCHES) <br />INSULATION CONDUCTIVITY <br />NOMINAL PIPE OR TUBE SIZE (INCHES) <br />FLUID OPERATING <br />TEMPERATURE <br />RANGE AND USAGE <br />CONDUCTIVITY <br />MEAN RATING <br />1" TO < <br />1-1/2" TO <br />(F) <br />BTU x IN/(H x FT'x 'F) <br />TEMPERATURE," <br /><1 <br />1-1/2" <br />< 4" <br />4" TO <8" <br />18„ <br />>350 <br />0.32-0.34 250 <br />4.5 <br />5.0 <br />5.0 <br />5.0 <br />5.0 <br />251-350 <br />0.29-0.32 200 <br />3.0 <br />4.0 <br />4.5 <br />4.5 <br />4.5 <br />201-250 <br />0.27-0.30 150 <br />2.5 <br />2.5 <br />2.5 <br />3.0 <br />3.0 <br />141-200 <br />0.25-0.29 125 <br />1.5 <br />1.5 <br />2.0 <br />2.0 <br />2.0 <br />105-140 <br />0.21-0.28 100 <br />1.0 <br />1.0 <br />1.5 <br />1.5 <br />1.5 <br />40-60 <br />0.21-0.27 75 <br />0.5 <br />0.5 <br />1.0 <br />1.0 <br />1.0 <br /><40 <br />0.20-0.26 75 <br />0.5 <br />1.0 <br />1.0 <br />1.0 <br />1.5 <br />NOTE: REFER TO 2018 <br />WEED FOR TABLE FOOTNOTES, <br />13. INSULATE ALL DUCT <br />WORK PER THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS AND PER SECTION C403.10.1 <br />AND <br />PER TABLE C403.10.1.1 AND C403.10.1.2. <br />TABLE C403.10.1.1 - OUTDOOR AIR DUCTWORK INSULATION <br />CLIMATE <br />MINIMUM INSTALLEDZONE <br />DUCT SYSTEM <br />DUCT LOCATION AND USE <br />AIRFLOW <br />DUCT INSULATION <br />R-VALUE <br />OUTDOOR AIR <br />INSIDE CONDITIONED SPACE AND UPSTREAM OF AUTOMATIC <br />4C AND 5B <br />>2800 CFM <br />R-16 <br />SHUTOFF DAMPER <br />- <br />OUTDOOR AIR <br />INSIDE CONDITIONED SPACE AND DOWNSTREAM OF <br />4C <br />>2800 CFM <br />R-8 <br />AUTOMATIC SHUTOFF DAMPER TO HVAC UNIT OR ROOM <br />- <br />OUTDOOR AIR <br />INSIDE CONDITIONED SPACE AND DOWNSTREAM OF <br />5B <br />>2800 CFM <br />R-12 <br />AUTOMATIC SHUTOFF DAMPER TO HVAC UNIT OR ROOM <br />- <br />OUTDOOR AIR <br />INSIDE CONDITIONED SPACE <br />4C AND 5B <br /><2800 CFM <br />R-7 <br />NOTE: REFER TO 2018 WSEC FOR TABLE FOOTNOTES. <br />TABLE C403.10.1.2 - SUPPLY, RETURN AND RELIEF AIR DUCTWORK INSULATION <br />DUCT SYSTEM <br />DUCT LOCATION AND USE <br />CLIMATE ZONE <br />R-VALUE <br />SUPPLY AIR OR <br />OUTSIDE THE BUILDING (OUTDOORS AND EXPOSED TO WEATHER) <br />4C <br />R-8 <br />RETURN AIR <br />SUPPLY AlR OR <br />OUTSIDE THE BUILDING (OUTDOORS AND EXPOSED TO WEATHER) <br />5B <br />R-12 <br />RETURN AIR <br />SUPPLY AIR OR <br />UNCONDITIONED SPACE (ENCLOSED BUT NOT IN THE BUILDING <br />RETURN AIR <br />CONDITIONED ENVELOPE) <br />qC AND 5B <br />R-6 <br />SUPPLY AIR OR <br />UNCONDITIONED SPACE WHERE THE DUCT CONVEYS AIR THAT IS WITHIN <br />RETURN AIR <br />157 OF THE AIR TEMPERATURE OF THE SURROUNDING UNCONDITIONED <br />4C AND 5B <br />R-3.3 <br />SPACE <br />SUPPLY AIR OR <br />WHERE LOCATED IN A BUILDING ENVELOPE ASSEMBLY <br />4C AND 5B <br />R-16 <br />RETURN AIR <br />WITHIN CONDITIONED SPACE WHERE THE SUPPLY DUCT CONVEYS AIR <br />SUPPLY AIR <br />THAT IS LESS THAN 557 OR GREATER THAN 1057 <br />4C AND 5B <br />R-3.3 <br />WITHIN CONDITIONED SPACE THAT THE DUCT DIRECTLY SERVES WHERE <br />SUPPLY AIR <br />THE SUPPLY DUCT CONVEYS AIR THAT IS LESS THAN 557 OR GREATER <br />4C AND 5B <br />NONE <br />THAN 105T <br />SUPPLY AIR <br />WITHIN CONDITIONED SPACE WHERE THE SUPPLY DUCT CONVEYS AIR <br />4C AND 5B <br />NONE <br />THAT IS 557 OR GREATER AND 105T OR LESS <br />RETURN OR <br />WITHIN CONDITIONED SPACE, DOWNSTREAM OF AN ENERGY RECOVERY <br />EXHAUST AIR <br />MEDIA, UPSTREAM OF AN AUTOMATIC SHUTOFF DAMPER <br />4C <br />R-8 <br />RETURN OR <br />WITHIN CONDITIONED SPACE, DOWNSTREAM OF AN ENERGY RECOVERY <br />EXHAUST AIR <br />MEDIA, UPSTREAM OF AN AUTOMATIC SHUTOFF DAMPER <br />59 <br />R-12 <br />RETURN OR <br />CONDITIONED SPACE AND DOWNSTREAM OF AN AUTOMATIC SHUTOFF <br />4C AND 5B <br />R-16 <br />EXHAUST AIR <br />DAMPER <br />NOTE: REFER TO 2018 WSEC FOR TABLE FOOTNOTES. <br />14. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS <br />REQUIRED BY SECTION C403.10.2. DUCT TAPE NOT ALLOWED. <br />15. DUCTWORK STATIC PRESSURE CLASSES: <br />DUCTWORK PRESSURE CLASSES <br />PRESSURE CLASS <br />WATER COLUMN OF ASSOCIATED EQUIPMENT <br />"LOW PRESSURE" <br />UP TO 2 INCHES <br />"MEDIUM PRESSURE" <br />GREATER THAN 2 INCHES TO LESS THAN 3 INCHES <br />HIGH PRESSURE" <br />3 INCHES AND ABOVE <br />16. PROVIDE BALANCING DEVICES IN ALL BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C408.2.2.1 AND C408.2.22 <br />AND AS INDICATED ON THE CONTRACT DOCUMENTS. PROVIDE ALL BALANCING DEVICES NEEDED TO ADJUST EQUIPMENT TO THE DESIGN FLOW VALUES <br />INDICATED ON THE PLANS AND SCHEDULES. <br />17. PROVIDE ISOLATION VALVES FOR ALL EQUIPMENT CONNECTED TO FLUID PIPING. <br />18, HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2. CONTRACTOR SHALL HIRE A BALANCE SPECIALIST AND PROVIDE <br />RESOURCES TO SUPPORT THE REQUIRED BALANCING ACTIVITIES. REFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. <br />19. CONTRACTOR SHALL PROVIDE COMMISSIONING AND REPORT OF COMMISSIONING SHALL BE SUBMITTED TO THE OWNER AS REQUIRED BY SECTION C408. <br />COMMISSIONING SHALL CONSIST OF A COMMISSIONING PLAN, BALANCING, FUNCTIONAL PERFORMANCE TESTING, POST CONSTRUCTION COMMISSIONING, <br />TRAINING, REPORTS AND ACCEPTANCE. SUBMIT COMMISSIONING COMPLIANCE CHECKLIST TO BUILDING OFFICIAL UPON COMPLETION. REFER TO THE <br />SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. <br />20. PROVIDE CLASS I MOTORIZED SHUTOFF DAMPERS AT ALL LOCATIONS REQUIRED BY SECTION C403.7.8.1. <br />21. DAMPERS SHALL COMPLY NTH SECTION C403.7.8.3, INCLUDING DAMPERS INTEGRAL TO HVAC EQUIPMENT, AND SHALL HAVE A MAXIMUM LEAKAGE <br />RATE WHEN TESTED IN ACCORDANCE WITH AMCA STANDARD 500D OF (AT 1.0 INCH W.G.): <br />MOTORIZED DAMPERS: 4 CFM/FT2 OF DAMPER AREA. <br />NON -MOTORIZED DAMPERS: 20 CFM/FT2 OF DAMPER AREA. <br />NON -MOTORIZED DAMPERS SMALLER THAN 24 INCHES IN EITHER DIMENSION: 40 CFM/FT2 OF DAMPER AREA. <br />22. ALL DUCT SYSTEMS SHALL BE SEALED TO A LEAKAGE RATE NOT TO EXCEED 4 PERCENT OF THE FAN FLOW IF THE DUCT SYSTEM: IS CONNECTED <br />TO A HIGH-PRESSURE OR MEDIUM -PRESSURE PIECE OF AIR MOVING EQUIPMENT; OR HAS ANY DUCT SURFACE AREA LOCATED IN ANY <br />UNCONDITIONED SPACE. THE LEAKAGE RATE SHALL BE CONFIRMED THROUGH FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN ACCORDANCE WITH <br />SMACNA HVAC AIR DUCT LEAKAGE TEST MANUAL. <br />2018 WASHINGTON STATE MECHANICAL CODE (IMC AMENDMENTS) NOTES <br />1. ALL EQUIPMENT SHALL BE PROVIDED WITH PERMANENT FACTORY APPLIED NAMEPLATES PER SECTION 301.9. REFER TO SPECIFICATIONS FOR PROJECT SPECIFIC LABELING REQUIREMENTS. <br />2. ALL EQUIPMENT SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 303 WHEN INSTALLED IN A LOCATION NOT AS SHOWN ON THE DESIGN PLANS. <br />3. ALL PIPING SHALL BE SUPPORTED PER TABLE 305.4. <br />TABLE 305.4 - PIPING SUPPORT SPACING° <br />PIPING MATERIAL <br />MAXIMUM HORIZONTAL SPACING (FT) <br />MAXIMUM VERTICAL SPACING (FT) <br />ASS PIPE <br />4 <br />10` <br />ALUMINUM PIPE AND TUBING <br />10 <br />15 <br />CAST IRON PIPE' <br />5 <br />15 <br />COPPER OR COPPER -ALLOY PIPE <br />12 <br />10 <br />COPPER OR COPPER -ALLOY TUBING <br />8 <br />10 <br />CPVC PIPE OR TUBING, 1 INCH AND SMALLER <br />3 <br />10` <br />CPVC PIPE OR TUBING, 1 1/4 INCHES AND LARGER <br />4 <br />10` <br />LEAD PIPE <br />CONTINUOUS <br />4 <br />PB PIPE OR TUBING <br />2-2/3 (32 INCHES) <br />4 <br />PE-RT 1 INCH AND SMALLER <br />2-2/3 (32 INCHES) <br />10` <br />PE-RT 1 1/4 INCHES AND LARGER <br />4 <br />101 <br />PEX TUBING 1 INCH AND SMALLER <br />2-2/3 (32 INCHES) <br />10` <br />PEX TUBING 1 1/4 INCHES AND LARGER <br />4 <br />10` <br />POLYPROPYLENE (PP) PIPE OR TUBING, i INCH AND SMALLER <br />2-2/3 (32 INCHES) <br />10` <br />POLYPROPYLENE (PP) PIPE OR TUBING, 1 1/4 INCHES AND LARGER <br />4 <br />10` <br />PVC PIPE <br />4 <br />10` <br />STEEL TUBING <br />8 <br />10 <br />STEEL PIPE <br />12 <br />15 <br />IAULE hWINUILS: <br />a. SEE SECTION 301.18. <br />b. THE MAXIMUM HORIZONTAL SPACING OF CAST IRON PIPE HANGERS SHALL BE INCREASED TO 10 FT. WHERE 10-FOOT LENGTHS OF PIPE ARE INSTALLED. <br />c. MID -STORY GUIDE. <br />4. PROVIDE EQUIPMENT WITH SERVICE AND INSTALLATION CLEARANCES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. ALL EQUIPMENT SHALL BE INSTALLED WITH A LEVEL WORKING SPACE <br />NOT LESS THAN 30 INCH BY 30 INCH ON THE MAINTENANCE SIDE OF THE EQUIPMENT PER SECTION 306.1 WHERE SMALLER AREAS ARE NOTED BY THE MANUFACTURER'S GUIDES. <br />5. ROUTE ALL CONDENSATE PIPING PER PLAN AND AT SIZE SHOWN ON PLAN. WHERE NOT SHOWN ON PLAN, CONDENSATE SHALL BE ROUTED TO THE NEAREST FIXTURE TAILPIECE AND <br />SHALL BE SIZED PER TABLE 307.2.2. WHERE OVERFLOW OF THE PRIMARY CONDENSATE MAY CAUSE DAMAGE TO BUILDING COMPONENTS, PROVIDE AN AUXILIARY AND SECONDARY DRAIN <br />SYSTEM PER SECTION 307.2.3. <br />TABLE 307.2.2 - CONDENSATE DRAIN SIZING <br />EQUIPMENT CAPACITY <br />MINIMUM CONDENSATE PIPE DIAMETER <br />UP TO 20 TONS OF REFRIGERATION <br />3/4 INCH <br />OVER 20 TONS TO 40 TONS OF REFRIGERATION <br />1 INCH <br />OVER 40 TONS TO 90 TONS OF REFRIGERATION <br />1-1/4 INCH <br />OVER 90 TONS TO 125 TONS OF REFRIGERATION <br />1-1/2 INCH <br />OVER 125 TONS TO 250 TONS OF REFRIGERATION <br />2 INCH <br />6. PROVIDE ALL CONDENSATE LINES WITH TRAPS PER SECTION 307.2.4. DUCTLESS SPLIT SYSTEMS SHALL BE PROVIDED WITH AN INLINE CHECK VALVE PER SECTION 307.2.4.1. CONSULT THE <br />MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLATION OF TRAPS ON EQUIPMENT CONDENSATE DRAINS. <br />7. MAINTAIN CLEARANCE TO/FROM OUTSIDE AIR INTAKES PER SECTION 401.4. <br />8. MAINTAIN CLEARANCE TO/FROM EXHAUST AIR OPENINGS PER SECTION 501.3.1. <br />9, ALL EQUIPMENT LOCATED IN PLENUMS SHALL BE RATED FOR USE IN PLENUMS. <br />THE GREENBUSCH GROUP,12_9EYC <br />do ry x0 <br />(2 0) 8-d589 5u�(20e)G.l]e oe 9F�ut <br />Silver Lake Elementary <br />Boiler Replacement <br />address: <br />12815 Bothell -Everett Highway <br />Everett, WA 98208-6630 <br />design phase: <br />PERMIT <br />SET <br />revisions: <br />no. description date <br />SP��OF WAS�Co <br />53373 <br />ONAL�' <br />design by: <br />R L / A V <br />drawn by: <br />J A / J Z <br />scale: <br />a s n o t e d <br />date: <br />11 / 15/2022 <br />job no.: <br />2022.125 <br />sheet title: <br />WA CODE NOTES <br />approvals: <br />sheet number: <br />M0.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.