Laserfiche WebLink
REMOVE (E) <br />H1 CLIP <br />(E) GLIB, V.I.F. <br />OF <br />EXTEND PLYWOOD TO FAR EDGE OF (N) 2x VERT <br />2'-6" MIN (FIELD VERIFY) i <br />I <br />A34 EA. SIDE <br />I <br />TO 2x VERT <br />\ / CUT TO FIT A 2x4 <br />VERT A M B <br />I <br />}1-------------------L <br />-- SIMPSON HU38 <br />#8 x 2" WOOD SCREWS <br />@ 2" O/C AT TOP & <br />BOTT, TYP. EA. SIDE - <br />/2 2 <br />. 37388 <br />s L <br />SfONAL <br />THIS ELECTRONIC S•L AND SIGNATURE IS <br />APPLIED WDIGITALITHIN AN EL <br />ECTRONIC DOCUMENT. <br />SIGNATURE I' A"LIED AT ONE <br />Page 24 of 24 <br />FACE OF (E) DUCT, FIELD VERIFY LOCATION <br />#8 x 2" WOOD SCREWS @ 2" O/C ALONG <br />DIAGONAL, STAGGERED, TYP. EA. SIDE <br />CUT TO FIT A 2x4 VERT AT DIAGONAL <br />(E) ROOF SHTG <br />(E) 16" WOOD TRUSS, V.I.F. <br />-- #8 x 2" WOOD SCREWS@ 2" O/C AT VERTS EA. <br />END, STAGGERED, TYP. EA. SIDE (16 TOTAL) <br />15/32" PLYWOOD EA. SIDE <br />NOTE: <br />PROVIDE (E) TRUSS REINFORCEMENTS PER SSK-03 AT <br />(3) TRUSSES UNDER NEW MECH UNITS, AT EA END OF <br />EA. TRUSS (12 LOCATIONS TOTAL), NOTIFY E.O.R. OF <br />ANY CONFLICTS OR DISCREPANCIES FOUND. <br />KI NGWORKS <br />STRUCTURAL <br />ENGINEERS <br />600 Dupont St, Suite B 360.714.8260 <br />Bellingham, WA 98225 www.king-works.com <br />EXISTING JOIST END REINFORCEMENT @ DUCT CONFLICT <br />PORT OF EVERETT <br />- MARINA VILLAGE RTU REPLACEMENT <br />Project number 22100 <br />SSK-04 <br />Date 05/31/2022 <br />Drawn by Author <br />Checked by Checker <br />Scale 1" =1'-0" <br />© copyright Kingworks Consulting Engineers PLLC: 2021 <br />5r31/2022 4:la:ua Nm <br />