My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 KINGS PL 2024-01-26
>
Address Records
>
KINGS PL
>
607
>
607 KINGS PL 2024-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2024 11:52:29 AM
Creation date
1/5/2024 11:07:28 AM
Metadata
Fields
Template:
Address Document
Street Name
KINGS PL
Street Number
607
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Powered by MECHANICAL SPECIFICATION <br /> r DUO ® Format 74.0in x 41.lin x 1.26in(including frame) <br /> (1879 mm x 1045 mm x 32 mm) 14.0•(1°'°mm, 16.0`(306.6 mml <br /> 420'ry000mm1 <br /> Weight 48.5 lbs(22.0 kg) <br /> z 40.3'U260mm) <br /> S" Front Cover 0.13in(3.2mm)thermally pre-stressed glass with - <br /> s <br /> -I r"fi anti-reflection technology hA o <br /> Back Cover Composite film 39.1'ry98mml <br /> - - -- - - Frame Black anodized aluminum <br /> Cell 6 x 22 monocrystalline Q.ANTUM solar half cells <br /> Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in <br /> (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes E=e.�� _°.3't336amml <br /> Cable 4mm2Solar cable;(+)>-49.2in(1250mm),(-)>_49.2in(1250mm) <br /> Connector St&ubll MC4;IP68 + 4;M 11 P.(DMLq - <br /> SYSTEM INFO. <br /> DE-A 0.931(=8m1 l <br /> -010.33'(0.6 mm1 (20)HANWHA Q CELL Q.PEAK DUO BLK <br /> 6.9e`(34.6-,1 M L-G l0+(400 W) <br /> (20)ENPHASE IQ7PLUS-72-2-US(24OV) <br /> . • , ELECTRICAL CHARACTERISTICS DC SYSTEM SIZE:6.00 KWDC <br /> POWER CLASS 385 390 395 400 405 AC SYSTEM SIZE:5.90 KWAC <br /> MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5 W/-0 W) <br /> Power atMPP1 PW IWI 385 390 395 400 405 REVISIONS <br /> b <br /> Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 DESCRIPTION DATE REV <br /> E <br /> 5jR o Open Circuit Voltage' Voc IV] 45.19 45.23 45,27 45.30 45.34 <br /> • , c <br /> Current at MPP IMpp [A] 10.59 10.65 10.71 10.77 10.83 <br /> TOP BRAND PV ' Voltage at MPP Vm,, [V] 36.36 36.62 36.88 3713 37.39 <br /> ' Efficiency' rl [%] >_19.6 >_19.9 >_20.1 >_20.4 >_20.6 <br /> EUROPE <br /> MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT3 Signature with Seal <br /> Warranty U21 QCELLS Power at MPP PMPP [W] 288.8 292.6 296.3 300.1 303.8 <br /> Pxu sPa,mrm9„oe Yield Security E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 <br /> 0 <br /> 'c <br /> Open Circuit Voltage Voc [V] 42.62 42.65 42.69 42.72 42.76 <br /> BREAKING THE 20%EFFICIENCY BARRIER 2 Current at MPP IMPP [A] 8.35 8.41 8.46 8.51 8.57 <br /> Q.ANTUM DUO Z Technology with zero gap cell layout Voltage at MPP vmpp [V] 34.59 34.81 35.03 35.25 35.46 <br /> boosts module efficiency up to 20.9%. 'Measurement tolerances PMPp±3%;Isc;Vo,±5%at STC:1000 W/m3,25±2°C,AM 1.5 according to IEC 60904-3.3800 W/m3,NMOT,spectrum AM 1.5 <br /> O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE <br /> THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY °° _°ELL3 E 130 --T-----r-----r----1---- <br /> Q CELLS is the first solar module manufacturer to ass the most com rehen- u r At least 98%of nominal power during <br /> p p w w � bi Flrst year.Thereafter max.0.5% isive quality programme in the industry:The new"Quality Controlled PV"of LLa s. ____________ degradation peryeacAtleasts3.5% ROJECT NAME&ADDRESo <br /> of nominal power up to 10 years.AtP S <br /> the independent certification institute TOV Rheinland. _ least 86%of nominal power upto 25 years. -z <br /> INNOVATIVE ALL-WEATHER TECHNOLOGY All data within measurementtoleranc- <br /> Optimal yields,whatever the weather with excellent es.Full warranties in accordance with °a 360 <00 9 WO 10 the warra my terms of the O C ELLS IRRADIANCE IW/m'h z <br /> low-light and temperature behavior. o sales organisation of your respective o O <br /> e w =o1. country. O <br /> YEARS Typical module performance under low irradiance conditions in e M O <br /> comparison to STC conditions 25°C,1000W/m3 <br /> _ ENDURING HIGH PERFORMANCE n P ( ) (n w O <br /> Long-term yield security with Anti LID Technology,Anti PID TEMPERATURE COEFFICIENTS o W U ( O <br /> ` <br /> Technology',Hot Spot Protect and Traceable Quality Tra.Q"A. 0 Temperature Coefficient of 130 a [%/K] +0.04 Temperature Coefficient of Voc 9 [%/K] -0.27 w U Q (3) O <br /> Temperature Coefficient of PMpp y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) > z Q O <br /> EXTREME WEATHER RATING o J w O <br /> High-tech aluminum alloy frame,certified for PROPERTIES FOR SYSTEM DESIGN W Q Q O <br /> high SnOW(540010a)and Wind loads(4000 Pe). Maximum System Voltage Vsys [V] 1000(IEC)/1000(UL) PV module classification Class II p <br /> a Z O <br /> Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 m U) w O <br /> A RELIABLE INVESTMENT Q w Y <br /> �Aps Inclusive 25-year product Warrent and 25-year Max.Design Load,Push/Pulls [lbs/ft3] 75(3600 Pa)/55(2660 Pa) Permitted Module Temperature -40°F up to+185°F p <br /> Y P Y Y on--inuousDuty (-40°C up to+85'C) ® w ti w <br /> linear performance Warranty2. Max.Test Load,Push/Pull3 [lbs/ft'] 113(5400Pa)/84(4000Pa) <br /> 3See Installation Manual Z (..0 W Z <br /> 1 APTtest conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION U Z d <br /> 3 See data sheet on rear for further information. /� /� J Q <br /> UL -compliant, fa? '0 <br /> Quality Controlled PV-TOV Rheinland, ♦ L�bV'�-1 ,olVd��J loll -"1 OlO__O' IatiHdl <br /> I EC 61215:2016,I EC 61730:2011" ® L <br /> THE IDEAL SOLUTION FOR: U.S.PatentNo.9,893,216(solarcens>. SA Horizontal 76.4in 43.3in 48.Oin 1656lbs 24 24 32 - <br /> QCPVc rficeron ongdng. C -m 1US C E packaging 1940mm 1100mm 1220mm 751 kg pallets pallets modules _ DATE:03/31/2022 <br /> resideRooftop arrays on SHEET NAME <br /> Ljrj� residential buildings <br /> Nob:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further Information on approved installation and use of EQUIPMENT <br /> this product SPECIFICATION <br /> OCELLS 400Wp drum LS Center <br /> Drive, <br /> Suit SHEET SIZE <br /> Engineered in Germany 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 96 I EMAIL Inqulrypus.q-cells.com I WEB www.q-cells.us <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV-6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.