Data Sheet Enphase IQ Combiner 3
<br /> Enphase Networking
<br /> MODEL NUMBER
<br /> IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy'"printed circuit board for integrated revenue grade PV
<br /> X-IQ-AM1-240-3 production metering(ANSI C12.20+/-0.5 i)and optional*consumption monitoring(+/-2.5%).
<br /> ACCESSORIES and REPLACEMENT PARTS(not included,order separately)
<br /> Enphase Mobile Connect"
<br /> CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60
<br /> CELLMODEM-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,
<br /> CELLMODEM-M1(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.)
<br /> Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%). SYSTEM INFO.
<br /> Enphase The Enphase IQ Combiner 3r"' with Enphase CT-200-SPLIT
<br /> -Consumption monitorin is required for Enphase Storage Systems (20)HANWML Q CELL Q.PEAK DUO BLK
<br /> 9 9 P 9 Y ML-G10+(400W)
<br /> IQ Combiner 3 IQ Envoyr" consolidates interconnection Wireless USB adapter Installed at the IQEnvoy.For communications with Enphase Encharge'"storage and Enphase
<br /> COMMS-KIT-01 Enpower'"smart switch.Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner'" (20)EN PHASE IQ7PLUS-72-2-US(240V)
<br /> equipment into a single enclosure and and allows redundant wireless communication with Encharge and Enpower. DC SYSTEM SIZE:8.00 KWDC
<br /> Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. AC SYSTEM SIZE:5.90 KWAC
<br /> (X-IQ-AM1-240-3) streamlines PV and storage installations by BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210
<br /> BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 REVISIONS
<br /> providing a consistent, re-wired solution for BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220
<br /> P 9 p DESCRIPTION DATE REV
<br /> EPLC-01 Power line carrier(communication bridge pair),quantity-one pair
<br /> residential applications. It offers up to four XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01)
<br /> 2-pole input circuits and Eaton BR series XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3
<br /> busbar assembly. ELECTRICAL SPECIFICATIONS
<br /> y Rating Continuous duty Signature with Seal
<br /> System voltage 120/240 VAC,60 Hz
<br /> Eaton BR series busbar rating 125 A
<br /> Max.continuous current rating(output to grid) 65A
<br /> Max.fuse/circuit rating(output) 90 A
<br /> Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included)
<br /> Smart Max.continuous current rating(input from PV) 64A
<br /> Includes IQ Envoy for communication Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included
<br /> ,I and control Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy PROJECT NAME&ADDRESS
<br /> Flexible networking supports Wi-Fi, MECHANICAL DATA
<br /> h 1 Ethernet,or cellular Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets).
<br /> �I 1 Optional AC receptacle available for PLC Weight 7.5 kg(16.5 lbs) z
<br /> bridge Ambient temperature range -40°C to+46°C(-400 to 115°F) OM O
<br /> NL _ Provides production metering and optional O M
<br /> L Cooling Natural convection,plus heat shield W r
<br /> consumption monitoring w U N O
<br /> Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction w U Q O O
<br /> • '� Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors \ z i Q O
<br /> Simple 60 A breaker branch input: 4 to 1/0 AWG copper conductors / > �
<br /> Main lug combined output: 10 to 2/0 AWG copper conductors J L1J (n > O
<br /> Reduced size from previous combiner Neutral and ground: 14 to 1/0 copper conductors = �Z ~ O
<br /> Always follow local code requirements for conductor sizing.
<br /> Centered mounting brackets support single Altitude To 2000 meters(6,560 feet C/) ~
<br /> stud mounting Q Lj Y W
<br /> _ INTERNET CONNECTION OPTIONS
<br /> i
<br /> I
<br /> • Supports back and side conduit entry LLJ W �
<br /> Integrated Wi-Fi 802.11b/g/n z O
<br /> Up to four 2-pole branch circuits for 240 VAC (0 > z
<br /> plug-in breakers(not included) Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) z W d
<br /> - 80 A total PV or storage branch circuits Cellular Optional,CELLMODEM-01(3G)or CELLMODEM-03(4G)or CELLMODEM-M1(4G based LTE-M) J Q
<br /> (not included)
<br /> COMPLIANCE
<br /> Reliable Compliance,Combiner UL 1741, CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003
<br /> Production metering:ANSI C12.20 accuracy class 0.5(PV production) DATE:03/31/2022
<br /> Durable NRTL-certified NEMA type Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1
<br /> SHEET NAME
<br /> 3R enclosure
<br /> EQUIPMENT
<br /> Five-year limited warranty
<br /> UL UL listed To learn more about Enphase offerings,visit enphase.com SPECIFICATION
<br /> LISTEDSHEET SIZE
<br /> ©2018 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the
<br /> E N P H AS E. trademarks of Enphase Energy,Inc. E N P H AS .
<br /> E
<br /> To learn more about Enphase offerings,visit enphase.com V 2019-11-04 v ANSI B
<br /> 11" X 17"
<br /> SHEET NUMBER
<br /> PV-8