MODULE SPECIFICATIONS QCeIIs Q.PEAK DUO BLK ML-G10+395 DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS <br /> RATED POWER(STC) 395 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG.HIGH TEMPS MICROINVERTER TO MAX.SHORT CIRCUIT CURRRENT(ISC) = 9.7 A AC <br /> NNt- <br /> MODULE VOC 45.27 V DC STATE Washington JUNCTION BOX(1) MAX.CURRENT(ISC X1-2S)= 12.1 A AC <br /> MODULE VMP 36.88 V DC CITY Everett CONDUCTOR(TC-ER,COPPER(90'C))= 12 AWG BLUE RAVE N <br /> MODULE IMP 10.71 A DC WEATHER STATION SNOHOMISH C01 CONDUCTOR RATING= 30 A <br /> MODULE ISC 11.1 A DC ASHRAE EXTREME LOW TEMP('C) -51 AMB.TEMP.AMP.CORRECTION = I <br /> VOC CORRECTION -0.27%/'C IASHRAE 2%AVG.HIGH TEMP('C) 30 ADJUSTED AMP.= 30 > 12.1 1403 N. Research Way <br /> VMP CORRECTION -0.34%/'C JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 9.7 A AC Orem, UT 84097 <br /> SERIES FUSE RATING 20 A DC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 CIR 5 CIR 6 JUNCTION BOX(2) MAX.CURRENT(ISC X1.25)= 12.1 A AC 8ERAV.4480 <br /> W W W.BLU RAVENSOLAR.COM <br /> ADJ. MODULE VOC @ ASHRAE LOW TEMP 48.9 V DC NUMBER OF MODULES PER MPPT 8 7 CONDUCTOR(UF-B,COPPER(6('C))= 10 AWG CONFIDENTIAL-THE INFORMATION <br /> ADJ MODULE VMP @ ASHRAE 2%AVG.HIGH TEMP 32.2 V DC DC POWER RATING PER CIRCUIT(STC) 3160 2765 CONDUCTOR RATING= 30 A HEREIN CONTAINED SHALL NOT BE <br /> TOTAL MODULE NUMBER IS CONDUIT FILL DERATE= 1 USED FOR THE EOA NE <br /> NO <br /> RA R <br /> _ EXCEPT BLUE RAVENN SOLLAR NOR <br /> MICROINVERTER SPECIFICATIONS Enphase IQ8+Microlnverters STC RATING OF ARRAY 5925 AMB.TEMP.AMP.CORRECTION = 1 SHALL IT BE DISCLOSED IN WHOLE OR <br /> IN PART TO OTHERS OUTSIDE <br /> POWER POINT TRACKING(MPPT)MIN/MAX 30 • 58 V DC AC CURRENT @ MAX POWER POINT(IMP 9.7 8.5 ADJUSTED AMP.= 30 > 12.1 RECIPIENTS ORGANIZATION,EXCEPT <br /> MAXIMUM INPUT VOLTAGE 60 V DC MAX CURRENT(IMP X1.25) 12.1 10.5875 JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 9.7 A AC IN CONNECTION WITH THE SALE AND <br /> USE OF THE RESPECTIVE EQUIPMENT, <br /> MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 20 COMBINER BOX(3) MAX.CURRENT(ISC X1.25)= 12.1 A AC WITHOUT THE WRITTEN PERMISSION <br /> MAXIMUM USABLE DC INPUT POWER 440 W MAX.COMB.ARRAY AC CURRENT(IMP) 18.2 CONDUCTOR(UF-B,COPPER(60'C))= 10 AWG OF BLUE RAVEN SOLAR LLC. <br /> MAXIMUM OUTPUT CURRENT 1.21 A AC MAX.ARRAY AC POWER 435OW AC CONDUCTOR RATING= 30 A <br /> AC OVERCURRENT PROTECTION 20 A CONDUIT FILL DERATE= 0.8 NABCEP <br /> MAXIMUM OUTPUT POWER 290 W AC VOLTAGE RISE CALCULATIONS DIST(FT) COND. /RISE(V) VEND(V) %VRISE AMB.TEMP.AMP.CORRECTION = 1 CERTIFIED <br /> CEC WEIGHTED EFFICIENCY 97% VRISE SEC. 1(MICRO TO JBOX) 28.8 12 Cu. 0.93 240.93 0.39% ADJUSTED AMP.= 24 > 12.1 <br /> VRISE SEC.2(JBOX TO COMBINER BOX) 20 10 Cu. 0.49 240.49 0.20% COMBINER BOX TO INVERTER RATED AMPS= 18.2 A AC PV INSTALLATION <br /> AC PHOTOVOLATIC MODULE MARKING(NEC 690.52) _ VRISE SEC.3(COMBINER BOX TO POI) 5 lOCu. 0.23 240.23 0.10% MAIN PV OCPD(15) MAX.CURRENT(RATED AMPS X1.25)= 22.69 A AC PROFESSIONAL <br /> NOMINAL OPERATING AC VOLTAGE 240 V AC TOTAL VRISE 1-65 241.65 0.69% 1 CONDUCTOR(THWN-2,COPPER(75'C TERM.))= 10 AWG Scott Gurney <br /> #PV-011719-015866 <br /> NOMINAL OPERATING AC FREQUENCY 47-68 HZ AC CONDUCTOR RATING= 35 A <br /> MAXIMUM AC POWER 240 VA AC PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL NEC 690.54) CONDUIT FILL DERATE= 1 CONTRACTOR: <br /> MAXIMUM AC CURRENT 1.0 A AC AC OUTPUT CURRENT 18.2 A AC AMB.TEMP.AMP.CORRECTION= 1 BRS FIELD OPS <br /> MAXIMUM OCPD RATING FOR AC MODULE 20 A AC NOMINAL AC VOLTAGE 240 V AC ADJUSTED AMP.= 35 > 22.7 800-377-4480 <br /> U U <br /> GROUNDING NOTES WIRING &CONDUIT NOTES Z <br /> Q � <br /> 1.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690.47]AND[NEC 250.50-60]SHALL BE 1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE 0 3 Y <br /> PROVIDED. PER[NEC 690.47],THE GROUNDING ELECTRODE SYSTEM OF AN EXISTING BUILDING MAY BE APPLICATIONS. 00 M LO <br /> USED AND BE BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR(USE CC <br /> INA <br /> UATE,OR <br /> S ONLY <br /> C WATER PIPING,A <br /> L GROUNDING <br /> E WILL <br /> POLAR <br /> S BLOCK OR <br /> 00 <br /> USED AAT THE INVERTER TEER LOCAT ON ICONSISTIING OF A UL LISTED 8 FT GROUND ND ROD WITH ACORNDCLAMP.BE 3. NY(CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS DISALLOWED ABOVE G 0) 'CT Lo <br /> 2.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN LIVE PARTS,MEYERS HUBS RECOMMENDED <br /> THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER) IF SMALLER THAN#6 AWG COPPER WIRE 4.UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF E n O I r1 E E s O 0 WLli <br /> PER [NEC 250.64(B)]. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SURFACE IN ACCORDANCE WITH[NEC 110.2,110.3(A-B)]. 651 W.GALENA PARK BLVD.STE. 101 PHONE(SO 7)990-7775 LLiz 4- N N <br /> SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER[NEC 250.64(C)]. 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH WITH ROOF SURFACE TO BE USED FOR WIRE DRAPER,UTAH 84020 WWW.VEDTDRSE.ODM > 0 <br /> 3.GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN 8 AWG AND NO GREATER THAN 6 AWG MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. Z > 1= <br /> COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR CABLE LISTED AND ELECTRICAL ONLY 2 O <br /> 4.PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 250.122],AND ALL METAL IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT;ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS IJ J U) M W W <br /> PARTS OR MODULE FRAMES ACCORDING TO[NEC 690.461. REQUIRED. C > <br /> 5.MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC 690.42]. 7.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 690.8]FOR MULTIPLE c m > N <br /> 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A CONDUCTORS. <br /> MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 8.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8"ABOVE 11l a� <br /> 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (B)(2)(A)], [NEC TABLE <br /> MANUFACTURER'S INSTALLATION INSTRUCTIONS. 310.15(B)(3)(A)],&[NEC 310.15(13)(3)(C)]. p <br /> El- <br /> ' U (�[ <br /> 8.ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN 9.EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90-C RATED,WET AND UV RESISTANT,AND UL r l Co = •- 00 > U V <br /> GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP !�' ��1 �' sq,I I P . V 00 W Q in <br /> 9.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVISES EDGES. ' <br /> EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, <br /> 10.GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR STRANDED,AND BARE WHEN WET AND UV RESISTANT,RATED FOR 600V ��` =•'Jy 7 DRAWING BY: <br /> EXPOSED. 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND X 7 <br /> 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO [NEC 690.45] AND BE A MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. •, ' Premium CAD <br /> MINIMUM OF 10 AWG WHEN NOT EXPOSED TO DAMAGE (6 AWG SHALL BE USED WHEN EXPOSED TO 12.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION <br /> DAMAGE). 13.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS �I I j'1:4 �� PLOT DATE: <br /> 12.GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR CODED GREEN(OR MARKED 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DCGREEN 4 AWG OR LARGER). SITIVE-RED(OR MARKED RED),DC NEGATIVE-GREY(OR MARKED <br /> 'Fig k1 1i I t Kt�' _t <br /> 3.ALL ICONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE 15 POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED:GREY) ff 1��U�`Lt��� February 18, 2023 <br /> GROUNDED BUSHINGS AT BOTH ENDS. DC POSITIVE-GREY(OR MARKED GREY),DC NEGATIVE-BLACK(OR MARKED BLACK) <br /> 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.661, DC SYSTEM GEC SIZED 16.AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE A OR L1-BLACK,PHASE B OR L2-RED, PROJECT NUMBER: <br /> ACCORDING TO[NEC 250.166],MINIMUM 8 AWG WHEN INSULATED,6 AWG WHEN EXPOSED TO DAMAGE. PHASE C OR L3-BLUE,NEUTRAL-WHITE/GRAY EXPIRES: 06/05/2023 <br /> 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND 'USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE <br /> CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH[NEC 250.134]OR[NEC 250.136(A)] "USE-2 IS AVAILABLE AS UV WHITE 02/24/2023 710356 <br /> REGARDLESS OF VOLTAGE. 17.RIGID CONDUIT,IF INSTALLED,(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. <br /> 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, Firm License Number:2202 SHEET NAME: <br /> FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH [NEC 690.31], [NEC 250.118(10)]. DISCONNECTING VSE Project Number:02001.2875.231 <br /> MEANS SHALL COMPLY WITH[NEC 690.13]AND[NEC 690.151. ELEC CALCS <br /> 19.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE COMPLYING WITH[NEC <br /> 230.6(4)]AND SECURED NO GREATER THAN 6'APART PER[NEC 330.30(B)]. <br /> REVISION: PAGE NUMBER: <br /> 0 PV6 <br />