Laserfiche WebLink
STANDARD LABELS ADDITIONAL LABELS <br /> LABEL 1 LABEL 8 BLUE RAVEN <br /> JIVWARNING_ FOR PV SYSTEM DISCONNECTING MEANS WHERE THE O WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE <br /> LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE LOCATION OF ALL ELECTRIC POWER SOURCE <br /> ELECTRIC SHOCK HAZARD OPEN POSITION. MAIN DISTRIBUTION UTILITY DISCONNECT(S) DISCONNECTING MEANS ON OR IN THE PREMISES 1403 N. Research Way <br /> (2017 NEC 690.13(8)1 POWER TO THIS BUILDING IS ALSO SUPPLIED SHALL BE INSTALLED AT EACH SERVICE EQUIPMENTOrem, UT 84097 <br /> TERMINALS ON THE LINE AND (2020 NEC 690.13(8)1 FROM A ROOF MOUNTED SOLAR ARRAY WITH LOCATION AND AT THE LOCATION(S)OF THE SYSTEM `®� <br /> LOAD SIDES MAY BE ENERGIZED A RAPID SHUTDOWN DISCONNECTING MEANS DISCONNECT(S)FOR ALL ELECTRIC POWER v 800.377.4480 <br /> IN THE OPEN POSITION GROUPED AND LABELED WITHIN LINE OF SITE PRODUCTION SOURCES CAPABLE OF BEING TB IS I Ti E E R a <br /> W W W.BLUERAVENSOLAR.COM <br /> AND 10 FT OF THIS LOCATION INTERCONNECTED. CONFIDENTIAL-THE INFORMATION <br /> 651 W.GALENA PARK 9LVD.STE. 707 PHONE(BC?1)990-1775 <br /> [2017 NEC 705.10] DRAPER, UTAH 84020 WWW.VEC-E.- HEREIN CONTAINED SHALL NOT BE <br /> LABEL2 [2020 NEC 705.10] ELECTRICAL ONLY USEDFOR <br /> LUERA EN OLA NONER <br /> EXCEPT BLUE RAVEN SOLAR NOR <br /> PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT SHALL IT BE DISCLOSED IN WHOLE OR <br /> THE DISCONNECTING MEANS AS A POWER SOURCE LABEL 9 IN PART TO OTHERS OUTSIDE <br /> I AC DISCONNECTI AND WITH THE RATED AC OUTPUT CURRENT AND THE ! WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE RECIPIENTS ORGANIZATION,EXCEPT <br /> NOMINAL OPERATING AC VOLTAGE. LOCATION OF ALL ELECTRIC POWER SOURCE IN CONNECTION WITH THE SALE AND <br /> (2017 NEC 690.54] USE OF THE RESPECTIVE EQUIPMENT, <br /> RATED AC OUTPUT CURRENT 18.15A POWER TO THIS BUILDING IS ALSO DISCONNECTING MEANS ON OR IN THE PREMISES WITHOUT THE WRITTEN PERMISSION <br /> (2020 NEC 690.541 <br /> NOMINAL OPERATING AC VOLTAGE 240 V SUPPLSHALL BE INSTALLED AT EACH SERVICE EQUIPMENT OF BLUE RAVEN SOLAR LLC. <br /> IED FROM MAIN DISTRIBUTION LOCATION AND AT THE LOCATION(S)OF THE SYSTEM Q. •�i'�j <br /> UTILITY DISCONNECT LOCATED DISCONNECT(S)FOR ALL ELECTRIC POWER !► lel `, <br /> PRODUCTION SOURCES CAPABLE OF BEING : <br /> LABEL 3 INTERCONNECTED. ` � NABCEP <br /> IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL [2017 NEC 705.10] <br /> A WARNING ANYWHERE THAT IS POWERED BY BOTH THE UTILITY [2020 NEC 705.10] �~� CERTIFIED] <br /> DUAL POWER SUPPLY AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL PV INSTALLATION <br /> AND SUBPANELS. LABEL (1037{97 <br /> (2017 NEC 705.12(8)(3)] WARNING PERMANENT <br /> '� ki,1�iTR�R PROFESSIONAL <br /> PERMANENT PLAQUE OR DIRECTORY TO BE '� Scott Gurney <br /> SOURCES: UTILITY GRID AND (2020 NEC 705.12(8)(3)] LOCATED AT MAIN SERVICE EQUIPMENT DENOTING f���1JN�LE�L` <br /> PV SOLAR ELECTRIC SYSTEM <br /> POWER TO THIS BUILDING IS ALSO SUPPLIED THE LOCATION OF THE RAPID SHUTDOWN SYSTEM #PV-011719-015866 <br /> FROM A ROOF MOUNTED SOLAR ARRAY.SOLAR DISCONNECTING MEANS IF SOLAR ARRAY RAPID <br /> SHUTDOWN DISCONNECTING SWITCH IS NOT EXPIRES: 06/05/2023 CONTRACTOR: <br /> ARRAY RAPID SHUTDOWN DISCONNECT IS GROUPED AND WITHIN LINE OF SITE OF MAIN BRS FIELD OPS <br /> /� SERVICE DISCONNECTING MEANS. 02/24/2023 <br /> /1\ WARNING APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT LOCATED OUTSIDE NEXT TO THE UTILITY METER. 800-377-4480 <br /> 1 \ TO THE BACK-FED BREAKER FROM THE POWER (2017 NEC 705.10 AND 690.56(C)(1)(a)] Firm License Number: 2202 <br /> POWER SOURCE OUTPUT CONNECTION SOURCE. [2020 NEC 705.10 AND 690.56(C)] <br /> DO NOT RELOCATE [2017 NEC 705.12(8)(2)(3)(b)] VSE Project Number:U2001.2875.231 <br /> (2020 NEC 705.12(8)(3)(2)] <br /> THIS OVERCURRENT <br /> EL 11 0 <br /> DEVICE I WARNING PERM ANENT PLAQUE OR DIRECTORY TO BE U Q <br /> LOCATED AT AC COMBINER PANEL. '' Q <br /> PHOTOVOLTAIC SYSTEM [2017 NEC 110.21(8)] Z <br /> OWARNING LABELS COMBINER PANEL I2020NEC110.21(8)] O_ 00 <br /> APPLY TO THE PV COMBINER BOX Q Y CJ <br /> (2017 NEC 705.12(B)(2)(3)(c)] Q N Ln CV <br /> (2020 NEC 705.12(8)(3)(3)] DO NOT ADD LOADS C 00 <br /> THIS EQUIPMENT FED BY MULTIPLE 4 L6C <br /> SOURCES.TOTAL RATING OF ALL <br /> O p W W <br /> OVERCURRENT DEVICES,EXCLUDING LL - N N <br /> MAIN SUPPLY OVERCURRENT SUBPANEL Z 0 N - <br /> UTILITY MAIN AC PV PV COMBINER <br /> DEVICE,SHALL NOT EXCEED (IF INTERCONNECTION O <br /> AMPACITY OF BUSBAR. METER SERVICE PANEL IS MADE HERE) DISCONNECT METER BOX W I-( n (n(n <br /> W <br /> 00 00 00 00 � y <br /> SOLAR PV SYSTEM EQUIPPED LABEL 6 w a� <br /> BUILDINGS WITH PV SYSTEMS SHALL HAVE A N U` N N <br /> WITH RAPID SHUTDOWN PERMANENT LABEL LOCATED AT EACH SERVICE O O O O O O O = .V 00 > U V <br /> EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS (,� ll� QD w Q Q <br /> TURN RAPID SHUTDOWN ARE CONNECTED OR AT AN APPROVED READILY <br /> OFF"POSITION TO CH TO THE VISIBLE LOCATION AND SHALL INDICATE THE LOCATION0 <br /> O IF BREAKER OOR PLACARD 11 <br /> SHUT DOWN PV SYSTEM OF RAPID SHUTDOWN INITIATION DEVICES. IS USED DRAWING BY: <br /> AND REDUCE (2017 NEC 690.56(C)(1)(a)] <br /> SHOCK HAZARD PremiumCAD <br /> IN THE ARRAY [2020 NEC 690.56(C)] (:�QR 1 0 <br /> OR PLACARD PLOT DATE: <br /> LABEL 7 <br /> RAPID SHUTDOWN SIGN LOCATED AT RAPID SHUT DOWN DISCONNECTSWITCH FOR February 181 L023 <br /> SWITCH <br /> (2017 NEC 690.56(0)(3)] PROJECT NUMBER: <br /> SOLAR PV SYSTEM (2020 NEC 690.56(0)(2)] <br /> 710356 <br /> LABELING NOTES SHEET NAME: <br /> 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT LABELS <br /> REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL <br /> 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED <br /> 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: <br /> 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE 0 PV7 <br /> HANDWRITTEN[NEC 110.211 DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. <br />