MODULE SPECIFICATIONS QCeUs Q.PEAK DUO BLK ML-G10+395 DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS <br /> RATED POWER(STC) 395 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG.HIGH TEMPI MICROINVERTER TO MAX.SHORT CIRCUIT CURRRENT(ISC) = 14.5 A AC <br /> NNt- <br /> MODULE VOC 45.27 V DC STATE Washington JUNCTION BOX(1) MAX.CURRENT(ISC X1.25)= 18.2 A AC <br /> MODULE VMP 36.88 V DC CITY EVERETT CONDUCTOR(TC-ER,COPPER(90'C))= 12 AWG BLUE RAVEN <br /> MODULE IMP 10.71 A DC WEATHER STATION SNOHOMISH CO! CONDUCTOR RATING= 30 A <br /> MODULE ISC 11.1 A DC ASHRAE EXTREME LOW TEMP('C) -51 AMB.TEMP.AMP.CORRECTION = 1 <br /> VOC CORRECTION -0.27%/'C JASHRAE 2%AVG.HIGH TEMP('C) 30 ADJUSTED AMP.= 30 > 18.2 1403 N. Research Way <br /> VMP CORRECTION -0.34%/'C JUNCTION BOX TO MAX.SHORTCIRCUIT CURRRENT(ISC)= 14.S AAC Orem, UT 84097 <br /> SERIES FUSE RATING 20 A DC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 CIR 5 CIR 6 JUNCTION BOX(2) MAX.CURRENT(ISC X1.25)= 18.2 A AC 8ERAV.4480 <br /> WWW.BLURAVENSOLAR.COM <br /> ADJ. MODULE VOC @ ASHRAE LOW TEMP 48.9 V DC NUMBER OF MODULES PER MPPT 12 CONDUCTOR(UF-B,COPPER(60'C))= 10 AWG CONFIDENTIAL-THE INFORMATION <br /> A-DI--MODULE VMP @ ASHRAE 2%AVG.HIGH TEMP 32.2 V DC DC POWER RATI NG PER CIRCUIT(STC) 47_4_0CONDUCTOR RATING= 30 A HEREIN CONTAINED SHALL NOT BE <br /> - -- --------------------------- --- --- <br /> TOTAL MODULE NUMBER 12 CONDUIT FILL DERATE= 1 USED FOR THE EOLA NO <br /> RA R <br /> EXCEPT BLUE RAVENN SOANE <br /> R NOR <br /> MICROINVERTER SPECIFICATIONS Enphase IQ8.Microlnverters STC RATING OF ARRAY 4740 AMB.TEMP.AMP.CORRECTION= 1 SHALL IT BE DISCLOSED IN WHOLE OR <br /> IN PART TO OTHERS OUTSIDE <br /> POWER POINT TRACKING(MPPT)MIN/MAX 30 - 58 V DC AC CURRENT @ MAX POWER POINT(IMP 14.5 ADJUSTED AMP.= 30 > 18.2 RECIPIENTS ORGANIZATION,EXCEPT <br /> MAXIMUM INPUT VOLTAGE 60 V DC MAX CURRENT(IMP X1.25) 18.15 JUNCTION BOX TO MAX SHORT CIRCUIT CURRRENT(ISC)= 14.5 A AC IN CONNECTION WITH THE SALE AND <br /> USE OF THE RESPECTIVE EQUIPMENT, <br /> MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 COMBINER BOX(3) MAX.CURRENT(ISC X1.25)= 18.2 A AC WITHOUT THE WRITTEN PERMISSION <br /> MAXIMUM USABLE DC INPUT POWER 440 W MAX.COMB.ARRAY AC CURRENT(IMP) 14.5 CONDUCTOR(UF-B,COPPER(60'C))= 10 AWG OF BLUE RAVEN SOLAR LLC. <br /> MAXIMUM OUTPUT CURRENT 1.21 A AC MAX.ARRAY AC POWER 348OW AC CONDUCTOR RATING= 30 A <br /> AC OVERCURRENT PROTECTION 20 A CONDUIT FILL DERATE= 1NABCEP <br /> MAXIMUM OUTPUT POWER 290 W AC VOLTAGE RISE CALCULATIONS DIST(FT) COND. JRISE(V) VEND(V) %VRISE AMB.TEMP.AMP.CORRECTION= 1 CERTIFIED <br /> CEC WEIGHTED EFFICIENCY 97% VRISE SEC. 1(MICRO TO 160X) 43.2 12 Cu. 2.09 242.09 0.87% ADJUSTED AMP.= 30 > 18.2 <br /> VRISE SEC 2(JBOX TO COMBINER BOX) 25 10 Cu. 0.92 24092 0.38% COMBINER BOX TO INVERTER RATED AMPS= 14.5 A AC PV INSTALLATION <br /> AC PHOTOVOLATIC MODULE MARKING(NEC 690.52) VRISE SEC.3(COMBINER BOX TO POI) 5 10 Cu. 0-18 240.18 0.08% MAIN PV OCPD(15) MAX.CURRENT(RATED AMPS X1.25)= 18.15 A AC PROFESSIONAL <br /> NOMINAL OPERATING AC VOLTAGE 240 V AC TOTAL VRISE 3.20 243.20 1.33% CONDUCTOR(THWN-2,COPPER(75'C TERM.))= 10 AWG Scott Gurney <br /> #PV-011719-015866 <br /> NOMINAL OPERATING AC FREQUENCY 47-68 HZ AC CONDUCTOR RATING= 35 A <br /> MAXIMUM AC POWER 240 VA AC PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC 690.54) CONDUIT FILL DERATE= I CONTRACTOR: <br /> MAXIMUM AC CURRENT 1.0 A AC AC OUTPUT CURRENT 14.5 A AC AMB.TEMP.AMP.CORRECTION= 1 BRS FIELD OPS <br /> MAXIMUM OCPD RATING FOR AC MODULE 20 A AC INOMINALAC VOLTAGE 240 V AC ADJUSTED AMP.= 35 > 18.2 800-377-4480 <br /> U U <br /> GROUNDING NOTES WIRING &CONDUIT NOTES Z 00 Q 0 <br /> 1.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690.47]AND[NEC 250.50-60]SHALL BE 1.ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE 0 N <br /> PROVIDED. PER[NEC 690.47],THE GROUNDING ELECTRODE SYSTEM OF AN EXISTING BUILDING MAY BE APPLICATIONS. 00 <br /> USED AND BE BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR(USE Q C') 00 <br /> INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE POLARIS BLOCK OR NEUTRAL BAR). CC C <br /> USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CAMP. 3.ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS DISALLOWED ABOVE G 0 co <br /> 2.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN LIVE PARTS,MEYERS HUBS RECOMMENDED +• I) <br /> THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER) IF SMALLER THAN#6 AWG COPPER WIRE 4.UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF O W W <br /> PER [NEC 250.64(B)]. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SURFACE IN ACCORDANCE WITH[NEC 110.2,110.3(A-B)]. LL N N <br /> SPLICES OR 3.GROUNDING INTS AT BUSBARS WITHIN LISTED E ELECTRODE CONDUCTORS SHALL BE EQUIPMENT <br /> NO LESS THANE8 AWG AND)]. 5. SOLADECK JUNCTN BXS MOUNTED FLUSH NO GREATER THAN 6 AWG MANAGEMENT AND AS FO ASHOEDEROOFF PENETRATIONS FORIINTREORIOR CONDUIT RUNS.OF SURFACE TO BE USED FOR WIRE Zco <br /> COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR CABLE LISTED ANDCC CC <br /> 4.PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 250.122],AND ALL METAL IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT;ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS C 0 > G G <br /> PARTS OR MODULE FRAMES ACCORDING TO[NEC 690.461. REQUIRED. LU 0 W W <br /> 5.MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC 690.42]. 7.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 690.8]FOR MULTIPLE G <br /> 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A CONDUCTORS. O LL M L1J <br /> MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 8.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8"ABOVE 2 <br /> 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (B)(2)(A)], [NEC TABLE <br /> MANUFACTURER'S INSTALLATION INSTRUCTIONS. 310.15(B)(3)(A)],&[NEC 310.15(13)(3)(C)]. N LO w <br /> 8.ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN 9.EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90-C RATED,WET AND UV RESISTANT,AND UL = N > V V <br /> GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP U w N W Q <br /> 9.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVISES EDGES. <br /> EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, <br /> 10.GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR STRANDED,AND BARE WHEN WET AND UV RESISTANT,RATED FOR 600V DRAWING BY: <br /> EXPOSED. 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND <br /> 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO [NEC 690.45] AND BE A MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. Prem I U CTI CAD <br /> MINIMUM OF 10 AWG WHEN NOT EXPOSED TO DAMAGE (6 AWG SHALL BE USED WHEN EXPOSED TO 12.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION <br /> DAMAGE). 13.VOLTAGE DROP LIMITED TO T B FOR DC CIRCUITS AND 3%FOR ACIRCUITS 2023 0 3 0 <br /> 3.ALL PLOT DATE: <br /> 12.GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR CODED GREEN(OR MARKED 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC (�tiV1 W,GREEN h 1 <br /> IF 4 AWG OR LARGER).CON CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE POSITIVE-PO ITIVE GROUN ED SYSTEMS DC CONDUCTORS COOLOR CODED R MARKED GREY) ��� of WASyti lj • • March 2, 2023 <br /> GROUNDED BUSHINGS AT BOTH ENDS. DC POSITIVE-GREY(OR MARKED GREY),DC NEGATIVE-BLACK(OR MARKED BACK) <br /> 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.661, DC SYSTEM GEC SIZED 16.AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE A OR L1-BACK,PHASE B OR L2-RED, �T 0� PROJECT NUMBER: <br /> ACCORDING TO[NEC 250.166],MINIMUM 8 AWG WHEN INSULATED,6 AWG WHEN EXPOSED TO DAMAGE. PHASE C OR L3-BLUE,NEUTRAL-WHITE/GRAY •41 <br /> 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND 'USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE l - 714712 <br /> CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH[NEC 250.134]OR[NEC 250.136(A)] "USE-2 IS AVAILABLE AS UV WHITE '• <br /> REGARDLESS OF VOLTAGE. 17.RIGID CONDUIT,IF INSTALLED,(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. A G <br /> 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, PO ,PF 54072 �� SHEET NAME: <br /> FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH [NEC 690.31], [NEC 250.118(10)]. DISCONNECTINGC1ST£� 0 O 0 <br /> MEANS SHALL COMPLY WITH[NEC 690.13]AND[NEC 690.151. �sSZOEAG` E L EC CALCS <br /> 19.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE COMPLYING WITH[NEC NAI <br /> 230.6(4)]AND SECURED NO GREATER THAN 6'APART PER[NEC 330.30(B)]. <br /> REVISION: PAGE NUMBER: <br /> 0 PV6 <br />