Laserfiche WebLink
II 1 <br /> MECHANICAL EQUIPMENT CONNECTION SCHEDULE-BOILERROOM GENERAL NOTES I <br /> EQUIPMENT CONNECTION TYPE FEEDER CONDUIT SHALL BE ROUTED UP AND NOT BLOCK OTHER TRADES. <br /> DISC. DISC. RECEPT. CONN. ETM'.ilrA COIISYIt811tS�IIIC. <br /> TAG VOLTAGE PH HP KW FLA MCA FRAME FUSE COMBO (NEMA) MANUAL ONLY CONDUIT W IRE(Cu) 19015 36th Avenue West,Suite E <br /> DETAIL NOTES Lynnwood,Washington 98036 <br /> BLDG B-1 120 1 7 9 30 15 3/4" 2#12,1#12 GND Phone(426)775-1799 FAX(425)774-9870 <br /> B-2 120 1 7 9 30 15 3/4" 2#12,1#12 GND <br /> E D EXISTING EQUIPMENT AND WIRING TO BE REMOVED. <br /> P-1 208 3 5 17.5 21.9 30 25 3/4" 4#12,1#12 GND <br /> P-2 208 3 5 - ITS 21.9 30 25 - - - - 3/4" 4#12,1#12 GND REMOVE EXISTING WIRING BACK TO PANEL IF APPLICABLE. <br /> 0 SPA 208 1 1 8 10 30 15 - - - - 3/4" 3#12,1#12 GND D EXISTING CONDUIT FROM J-BOX TO PANEL DS MAY BE RE-USED AT <br /> 8P-2 208 1 1 - 8 10 30 15 - - - - 314" 3#12,1#12 GND THE CONTRACTOR'S DISCRETION.PROVIDE NEW WIRING.PROVIDE <br /> NEW CONDUIT IF REQUIRED. <br /> VFD-1 208 3 X <br /> VFD-2 208 3 - - - - - - XaD PROVIDE EMERGENCY POWER OFF(EPO),LOW VOLTAGE WIRING,AND <br /> CONDUIT TO BOILER CONTROLS TO SHUT OFF BOILER.COORDINATE <br /> REQUIREMENTS WITH BOILER MANUFACTURER. <br /> AREA OF WORK NOTES: DISCONNECT,FEEDER,AND ALL CONNECTIONS BY ELECTRICAL CONTRACTOR,UNLESS NOTED OTHERWISE. D WIRE TO J-BOX FOR TRANSFORMER FOR CO SENSOR.TRANSFORMER <br /> 2 COORD14ATE EXACT EQUIPMENT LOCATIONS,LOADS,AND CONNECTION TYPE WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH IN SUPPLIED BY CONTROL CONTRACTOR. <br /> 3. OUTDOOR EQUIPMENT SHALL BE NEMA 3R. D EMERGENCY BOILER DISCONNECT SWITCH TO BE CONTROLLED BY <br /> 4. 120V CONTROL WIRING AND 14TERLOCK WIRING BY ELECTRICAL CONTRACTOR. THE DOC SYSTEM.CONTROLS WORK BY ATS. <br /> 5. PROVIDE AN AUXILIARY CONTACT IN ALL DISCONNECT SWITCHES TO SIGNAL STATUS TO VFD AND CONTROL SYSTEM <br /> > KEY: <br /> 3 BLDG MANUAL 120V MANUAL MOTOR STARTER WITH THERMAL OVERLOAD <br /> COMBO COMBINATION FUSED DISCONNECT/MAGNETIC MOTOR STARTER WITH HOA,COIL VOLTAGE 12GV. PROJECT: <br /> RECEPT. RECEPTACLE.COORDINATE TYPE WITH EQUIPMENT SUPPLER SILVER LAKE ELEMENTARY <br /> m C CONWONLY EQUIPMENT CONNECTION <br /> VFD=VARIABLE FREQUENCY DRIVE,BY MECHANICAL BOILER REPLACEMENT <br /> BLDG <br /> B PORTABLES <br /> I <br /> BLDG A <br /> / <br /> KEY PLAN A' <br /> LOCATION: <br /> SCALE: 1" = 50'-0" N <br /> 12815 BOTHELL-EVERETT HW" <br /> EVERETT,WA 98208 <br /> (EXPOSED WIRES IN WALL) <br /> BOILER BOILER <br /> >> 1 2 xo. B�iB IaEYeox <br /> LO <br /> t (N)BOILER PUMP BP-1 (N)BOILER PUMP BP-2 <br /> L�P1-25,27 ��P1-29,31 <br /> 2 PUMP#1 <br /> 2 PUMP#2 <br /> (N)BOILER B-1 (N)BOILER B-2 <br /> 22 <br /> 1-10 P1-12 <br /> WATER HEATER (E)WATER HEATER <br /> F F <br /> EO: (N)VFD-1 O o.a�uuP uBz«x1 <br /> (N)P-1 PBaccY Bcacxa <br /> P1-16,18,20 <br /> CxEq(fD BY: <br /> (N)P-2 <br /> P1-22,24,26 <br /> t (N)VFD-2 Q., <br /> (E)BOILER EMERGENCY <br /> s C DISCONNECT SW <br /> BOILER ROOM s (N)BOILER EMERGENCY <br /> DISCONNECT SW BOILER ROOM 6 �� n. ad <br /> AIR DRYER t (EXPOSED <br /> WIRES IN PANEL P1 4 s <br /> OVERHEAD) (E)PANEL P1 x <br /> t <br /> L� <br /> ELECT. ROOM ELECT, ROOM <br /> ELECTRICAL DEMOLITION& <br /> INSTALLATION PLAN <br /> (E)PANEL P4 SEC 2 I'7 <br /> E)MAIN DISTRIBUTION PANEL CN PxnPc,xo <br /> PANEL P4 SEC 2 AIN DISTRIBUTION PANEL (E)PANEL P4 SEC 1 CD <br /> PANEL P4 SEC 1PANEL Y1 <br /> PANEL OR (E)PANEL DP1 (E)PANEL Y1 Bnh <br /> CN <br /> � ��r xucam <br /> N E1.0 <br /> ENLARGED MECHANICAL ROOM DEMOLITION PLAN ENLARGED MECHANICAL ROOM INSTALL PLANA' <br /> SCALE: 1/4"=V-0" <br /> N SCALE: 1 4"=1'-0" A <br /> www.awaelec.cnm @AWA,INC. <br /> e iaaa to s„iia­exmaxya or xA, mom. For C—dici—Ay­­aaa www.bxwa.com-Always v fy s-1 <br />