My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
617 LEGION DR 2024-03-01
>
Address Records
>
LEGION DR
>
617
>
617 LEGION DR 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 2:01:28 PM
Creation date
2/6/2024 3:31:38 PM
Metadata
Fields
Template:
Address Document
Street Name
LEGION DR
Street Number
617
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Drew Martin <br />From: Drew Martin <br />Sent: Friday, July 9, 2021 1:11 PM <br />To: Joe luckey'; Paula Sweeney <br />Subject: City of Everett Permit Services: 617 Legion Drive (B2104-076) - Second Building Intake <br />Review <br />Joe, <br />Please see the following supplemental comments, itemized for consistency with the comments emailed on <br />05/10/2021. Please send hardcopies of the revised drawings (2 sets) and any other support documentation (if <br />applicable) via the standard resubmittal process. The documents should include an itemized response letter addressing <br />all comments in the original 05/10/2021 email and below. Comments provided by the Planning Department on <br />05/03/2021 should also be addressed prior to resubmitting documents for review; a separate itemized letter should be <br />provided for Planning's review. <br />SuDolemental Comments: <br />3. See the following commens: <br />a. The door should specify a closer. See Section R302.5.1. <br />b. The new hallway includes a washer/dryer unit that appears to encroach on the minimum 3-foot hallway width <br />per Section R311.6, which is not permitted. <br />c. The new bonus room has been effectively configured to qualify as a bedroom (i.e., egress window, separation <br />from the garage). Smoke and CO alarms should be provided per Sections R314 and R315. The alarms should be <br />hardwired and interconnected as required. <br />4. The note is note sufficient. A detail specifying the construction should be included. <br />6. Sheet A001 does not appear to include a schedule of energy credits. The statement "Alternations do not need to <br />obtain energy credits" is not correct. This is an addition, defined in the WSEC as adding conditioned space to the <br />house. Energy credits are required. <br />7. Minimum clearances should be dimensioned on the drawings. <br />8. See Comment 11 below. <br />9. This comment is not sufficient. The required construction should be shown. <br />11. This comment has not been addressed. The existing construction of the space being converted must be shown. It is <br />required to comply with the current code for new construction. Note that this addition was originally constructed in <br />1958 and is not expected to comply with the current code requirements without modifications. All construction <br />requirements, including but not limited to foundations, framing, sill plate anchorage, roof construction, braced wall <br />panels, and framing fasteners, should be specified. See Sections R102.7 and R102.7.1. <br />12. The minimum dimensions for the stairs should be specified. Stairs should comply with Section R311.7. The stairs <br />should not encroach on the minimum 3-foot hall width per Section R311.6. <br />
The URL can be used to link to this page
Your browser does not support the video tag.