My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6902 COLUMBIA CT 2024-03-05
>
Address Records
>
COLUMBIA CT
>
6902
>
6902 COLUMBIA CT 2024-03-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2024 2:03:34 PM
Creation date
2/8/2024 3:37:48 PM
Metadata
Fields
Template:
Address Document
Street Name
COLUMBIA CT
Street Number
6902
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5. The drawings should clearly delineate between existing and new work using established drafting <br />standards. All demolition should be shown on the existing floor plans. All new construction should be <br />shown on the new floor plan. Where the proposed project includes modifications existing building <br />components (e.g., gypsum wall board, insulation, etc.), these components should be similarly delineated <br />from existing component that are not being altered. See IRC Section R106.1.1. <br />6. The scope of work appears to be incomplete. Based on an electrical inspection performed on 10/28/2021, <br />modifications to the house may include but are not limited to modifying walls, doors, floors, roof, <br />windows, sinks, showers, and toilets. All proposed work should be clearly shown in the drawings. See <br />Maus",IM111i81111 <br />Architectural: <br />7. New and modified bedrooms should have emergency egress openings. The minimum opening dimensions <br />and area, and maximum bottom sill opening height of the floor, should be specified. See IRC Section <br />R310. <br />8. Smoke and CO alarms should be provided per IRC Sections R314 and R315. The locations of all alarms <br />should be shown on the plans. A note should be included requiring the alarms to be hardwired, <br />interconnected, and provided with back-up battery power as required. Alarm clearances should comply <br />with Section R314.3 Item 4 and Section R314.3.1. <br />9. Insulation should be specified for all modifications to the exterior walls, floors, slab -on -grade, and <br />ceiling/roof cavities per WSEC Table 402.1.1. <br />Structural: <br />10. The proposed project includes structural work. Structural drawing should be submitted that include <br />framing and foundation plans, sections, details, construction schedules, fastening schedules, materials <br />requirements, general notes, special inspection requirements, etc. The drawings should substantiate <br />compliance with the prescriptive requirements of the IRC. See IRC Sections R106.1.1 and R301.1. <br />11. The modified load paths should comply with the prescriptive limitations of the IRC. Alternatively, an <br />engineered analysis and design may be performed per IRC Section R301.1.3; sealed and signed drawings <br />and calculations prepared by a professional engineer licensed in the state of Washington are required per <br />RCW 18.43.010, 18.43.020, and 18.43.070. See IRC Section R301.1. <br />12. The proposed project includes the demolition of non -bearing walls. Framing plans for the floor, ceiling, <br />and roof should be provided to substantiate that the walls are not load -bearing. The plans should also <br />include a note requiring the contractor to verify the walls are not load bearing prior to demolition. See IRC <br />Section R301.1. <br />13. Details for the construction of the new walls should be included. The details should specify connections <br />for the top and bottom framing plates to the existing structure. See IRC Sections R106.1.1 and R301.1. <br />14. The proposed design includes modifications to the existing wall bracing that may not comply with the <br />requirement of IRC Section R602.10. the locations and extents of modified braced wall lines should be <br />
The URL can be used to link to this page
Your browser does not support the video tag.