Laserfiche WebLink
N o <br /> a4 <br /> N g <br /> DIST.PANEL SCHEDULE:11/27/2023 (E)DIST.PANEL'PDP' PROJECT:Horizon ES Portable Rastroom Replacement PANEL SCHEDULE:11/27/2023 (E)PANEL-PT' PROJECT:Horlmn ES Portable Restroom Replacement PANEL SCHEDULE:11/2712023 PANEL'PT' PROJECT:Horizon ES Portable Restroom Replacement <br /> ---]CLASSIFICATION:NORMAL VOLTAGE:208Y/120V 30,4WIRE SECTION:101 1 CLASSIFICATION:NORMAL VOLTAGE:208/120V 10,-IRE SECTION:1 OF 1 CLASSIFICATION:NORMAL ]VOLTAGE:2013112-10,3-WIRE SECTION:1 OF 1 m <br /> FED FROM:(E)TRANSFORMER'DTPDP' MAINS:400A MAIN CIRCUIT BREAKER FED FROM: MAINS:100A MAIN CIRCUIT BREAKER FED FROM:(E)DIST.PANEL'PDP' MAINS:1 MA MAIN CIRCUIT BREAKER < P eqeq <br /> MOUNTING:FIELD VERIFY NEUTRAL:100%RATED MOUNTING:FLUSH NEUTRAL:100%RATED MOUNTING:FLUSH NEUTRAL:100%RATED g <br /> CKT BREAKER LOAD LOAD BREAKER CKi CKi BREAKER LOAD LOAD BREAKER CKT CKT BREAKER LOAD LOAD BREAKER CKT <br /> NOT ITEM DESCRIPTION NO. AMP POLE (VA) 0 (VA) AMP POLE NO. ITEM DESCRIPTION NOT NOT ITEM DESCRIPTION NO. AMP POLE (VA) 0 (VA) AMP POLE NO. ITEM DESCRIPTION NOT NOT ITEM DESCRIPTION NO. AMP POLE (VA) 0 (VA) AMP POLE NO. ITEM DESCRIPTION NOT <br /> E)PANEL'P-1' 1 100 2 6338 JA 7498 125 1 2 1 2 E)PANEL'P-5' HEATER 1 60 1 2 4500 A 4500 60 2 2 HEATER INT/EXT LIGHTING,EXHAUST FANS 1 20 1 117 A 1920 20 1 2 HEAT TRACE RECEPTACLE(GFEP) <br /> 3 5675 S 5880 4 3 4500 B 4500 4 GENERAL RECEPTACLE(3) 3 20 1 540 B 1650 25 1 4 WATER HEATER <br /> E)PANEL P-2' 5 100 26338 C 6938 100 2 6 E)PANEL'P-3' LIGHTING 5 20 1 559 A 6 SPACE HEAT RM 101 5 20 2 1500 A 1500 20 2 6 HEAT RM102 <br /> 7 5675 A 5675 8 RECEPTACLES 7 20 1 360 B 8 SPACE 7 1500 B 1500 8 <br /> E)PANEL'P-6/R7' 9 225 2 1]]48 B 5357 100 2 10 PANEL'PT' 1 SPACE 9 - - A - - 10 SPACE ERV1 9 15 1 160 A 160 15 1 10 SPACE <br /> 11 - - 19554 C 5190 - - 12 SPACE 11 B SPACE 11 B 12 SPACE Zjy-+JV 'n <br /> 13 20 1 A 20 1 14 Iv� <br /> 15 20 1 B 20 1 16 Q <br /> 17 20 1 C 20 1 18 <br /> 19 20 1 A 20 1 20 <br /> 21 20 1 B 20 1 22 <br /> 23 20 1 C 20 1 24 <br /> 25 20 1 A 20 1 26 .� 49958 <br /> 27 20 1 B 20 1 28 1 <br /> 29 20 1 C 20 1 30 NAL <br /> 31 20 1 A 20 1 32 <br /> 33 20 1 B 20 1 34 tiO <br /> 35 20 1 C 20 1 36 <br /> 37 20 1 A 20 1 38 <br /> 39 20 1 B 20 1 40 <br /> 41 20 1 C 20 1 42 <br /> LOAD CALCULATIONS LOAD CALCULATIONS LOAD CALCULATIONS <br /> LOAD DESCRIPTION CONN.(VA) DEMAND FACTOR CALC.(VA) LOAD DESCRIPTION CONN.(VA) DEMAND FACTOR CALC.(VA LOAD DESCRIPTION CONN.(VA) DEMAND FACTOR CALC.(VA) <br /> MISCELLANEOUS CONTINUOUS: - 125% - LOAD SUMMARY MISCELLANEOUS CONTINUOUS: - 125% - LOADSUMMARY MISCELLANEOUS CONTINUOUS: - 125% - LOADSUMMARY <br /> EQUIPMENT&MISCELLANEOUS: 67208 100% 67208 EQUIPMENT&MISCELLANEOUS: - 100% - EQUIPMENT&MISCELLANEOUS. - 100% - <br /> LIGHTING: 5]68 125% 7210 TOTAL LIGHTING: 559 125% 699 TOTAL LIGHTING: 117 125% 146 TOTAL <br /> LARGEST MOTOR: 160 125% 200 CONNECTED LOAD AMPS LARGEST MOTOR: - 125% - CONNECTED LOAD AMPS LARGEST MOTOR: 160 125% 200 CONNECTEDLOAD AMPS <br /> MOTORS: 160 10D% 160 PHASEA: 25,186VA 210A MOTORS: - 100% - MOTORS: 160 100% 160 <br /> RECEPTACLE: 10000 100% 10000 RECEPTACLE: 360 100% 360 PHASEA.9,559 VA BOA RECEPTACLE: 540 100% 540 PHASEA:5,357VA 45A <br /> RECEPTACLES OVER 1OkVA: 4400 50% 2200 PHASEB: 34,66OVA 289A R ECEPTACLES OVER 1 OWA: - 50% - RECEPTACLES OVER 1 CkVA. - 50% - <br /> ELECTRIC HEATING: 9570 10D% 9570 ELECTRIC HEATING: 18000 100% 18000 PHASE B:9,360 VA 78A ELECTRIC HEATING: 9570 100% 9570 PHASE B:5,190 VA 43 A <br /> PHASE C:38,020 VA 317 A <br /> TOTAL CALCULATED LOAD:96,548 VA TOTAL CALCULATED LOAD:19,059 VA TOTAL CALCULATED LOAD:10,616 VA <br /> TOTAL CALCULATED AMPS:263 A TOTAL CALCULATED AMPS:92A TOTAL CALCULATED AMPS:SIA <br /> TOTALS: 97,266 96,548 TOTALS: 18,919 19,059 TOTALS: 10,547 10,fi16 <br /> NOTES: HARGIS ENGINEERS,INC. NOTES:DISCONNECT EXISTING PANELBOARD FOR REMOVAL OF EXISTING PORTABLE RESTROOM HARGIS ENGINEERS,INC. NOTES:ALL BRANCH CIRCUITS ARE EXISTING,FURNISHED WITH REPLACEMENT PORTABLE RESTROOM. HARGIS ENGINEERS,INC. <br /> 1.EXISTING CIRCUIT BREAKER TO REMAIN.RECONNECT LOADSIDE TO REPLACEMENT PORTABLE RESTROOM PANELBOARD'PT 1201 THIRD AVENUE,SUITE 600 1. 1201 THI R D AVENU E,SU ITE 600 1. 1201 THI RD AVER U E,SU ITE 600 <br /> 2. SEATTLE,WA98101 2. SEATTLE,WA 98101 2. SEATTLE,WA 98101 <br /> 3. 3. 3. <br /> 4. PH.(206)448-33]6 4. PH.(206)448-3376 4. PH.(206)448-3376 <br /> 5. FAX,(206)448-4450 5. FAX.(206)4d8-4450 5. FAX.(206)d48-4450 <br /> PAN EL SCH EDU LE:05123/2022 (E)PANEL'P-1' PROJECT:Horizon ES Portable Restroom Replacement PANEL SCHEDULE:05/2312022 (E)PANEL'P-2' PROJECT:Horizon ES Portable Reslrocm Replacement PANEL SCHEDULE:05/23/2022 (E)PANEL'P-3' PROJECT:Horizon ES Portable Restroom Replacement <br /> CLASSIFICATION:NORMAL VOLTAGE:2081120V 10,3-WIRE SECTION:1 OF 1 CLASSIFICATION:NORMAL VOLTAGE:208t12OV 10,3-WIRE SECTION:1O'1 CLASSIFICATION:NORMAL VOLTAGE:208/120V 10,3-WIRE SECTION:1 OF 1 <br /> FED FROM:(E)DIST.PANEL'PDP' MAINS:1250 MAIN CIRCUIT BREAKER FED FROM:(E)DIST.PANEL'PDP' MAINS:125A MAIN CIRCUIT BREAKER FED FROM:(E)DIST.PANEL'PDP' MAINS:1250 MAIN CIRCUIT BREAKER <br /> MOUNTING:FLUSH NEUTRAL:100%RATED MOUNTING:FLUSH NEUTRAL:100%RATED MOUNTING:FLUSH NEUTRAL.100%RATED <br /> CKT BREAKER LOAD LOAD BREAKER CKT CKT BREAKER LOAD LOAD BREAKER CKT CKT BREAKER LOAD LOAD BREAKER CKT <br /> NOT ITEM DESCRIPTION NO, AMP POLE (VA) 0 (VA) <br /> AMP POLE N0. ITEM DESCRIPTION NOT NOT ITEM DESCRIPTION N0. AMP POLE (VA) 0 (VA) AMP POLE NO. ITEM DESCRIPTION NOT NOT ITEM DESCRIPTION NO. AMP POLE (VA) 0 (VA) AMP POLE NO, ITEM DESCRIPTION NOT <br /> UNIT VENTILATOR 1 60 2 4500 A 1118 20 1 2 LIGHTING UNITVENTILATOR 1 60 2 4500 A 1118 20 1 2 LIGHTING UNITVENTI IATOR 1 60 2 4500 A 1118 20 1 2 LIGHTING <br /> 3 4500 B 540 20 1 4 RECEPTACLES 3 4500 B 540 20 1 4 RECEPTACLES 3 4500 B 540 20 1 4 RECEPTACLES <br /> RECEPTACLE-TV 5 20 1 180 A 540 20 1 6 RECEPTACLES RECEPTACLE-TV 5 20 1 180 A 540 20 1 6 RECEPTACLES RECEPTACLE-TV 5 20 1 180 A 540 20 1 6 RECEPTACLES <br /> LIGHTING-SECURITY 7 20 1 95 B 540 20 1 8 RECEPTACLES LIGHTING-SECURITY 7 20 1 95 B 540 20 1 8 RECEPTACLES LIGHTING-SECURITY 7 20 1 95 B 540 20 1 8 RECEPTACLES <br /> PACE 9 A 20 1 10 PARE PACE 9 A 20 1 10 SPARE OF CABINET 9 600 A 20 1 10 PARE <br /> PACE 11 - - B 20 1 12 PARE PACE 11 - - B 20 1 12 SPARE PACE 11 - - B 20 1 12 PARE <br /> PACE 13 A 14 PACE PACE 13 A 14 SPACE PACE 13 A 14 PACE <br /> PACE 15 - - B - - i6 PACE PACE 15 - - B - - 16 SPACE PACE 15 - - B - - 16 PACE O <br /> PACE 17 - - A - - 18 PACE PACE 17 - - A - - 18 SPACE PACE 17 - - A - - 18 PACE <br /> PACE 19 B 20 PACE PACE 19 B 20 SPACE PACE 19 B 20 PACE <br /> PACE 21 - - A - - 22 PACE PACE 21 - - A - - 22 SPACE PACE :2 - - A - - 22 PACE O Z <br /> PACE 23 B 24 PACE PACE 23 B 24 SPACE PACE 23 B 24 PACE <br /> W <br /> U 2 <br /> � U/L <br /> LOAD CALCULATIONS LOAD CALCULATIONS LOAD CALCULATIONS y ` <br /> LOAD DESCRIPTION CONN.(VA) DEMAND FACTOR CALC.(VA) LOAD DESCRIPTION CONN.(VA) DEMAND FACTOR CALC.(VA) LOAD DESCRIPTION CONN.(VA) DEMAND FACTOR CALC.(VA) <br /> MISCELLANEOUS CONTINUOUS: - 125% - LOAD SUMMARY MISCELLANEOUSCONTINUOUS: - 125% - LOADSUMMARY MISCELLANEOUS CONTINUOUS: - 125% - LOADSUMMARY <br /> EQUIPMENT&MISCELLANEOUS: 9000 100% 9000 EQUIPMENT&MISCELLANEOUS: 9000 100% 9000 EQUIPMENT&MISCELLANEOUS: 9000 100% 9000 <br /> LIGHTING: 1213 125% 1516 TOTAL LIGHTING: 1213 125% 1516 TOTAL LIGHTING: 1213 125% 1516 TOTAL 1 1 1 <br /> LARGEST MOTOR: - 125% - CONNECTEDLOAD AMPS LARGEST MOTOR: - 125% - CONNECTED LOAD AMPS LARGEST MOTOR: - 125% - CONNECTED LOAD AMPS I ri <br /> MOTORS: - 100% - MOTORS: - 100% - MOTORS: - 100% - Of <br /> RECEPTACLE: 1800 1OD% 1800 PHASEA: 6,338VA 530 RECEPTACLE: 1800 700% 1800 PHASEA:6,338 VA 53A RECEPTACLE: 1800 100% 1800 PHASEA:6,938VA 58A <br /> RECEPTACLES OVER10kVA: - 50% - RECEPTACLES OVER1OkVA: - 50% - RECEPTACLES OVER ICkVA: - 50% - Z <br /> PHASE B: 5,6]5 VA 47 A PHASE B:5,6]5 VA 4]A PHASE B:5,fi75 VA 47 A VI I i <br /> TOTAL CALCULATED LOAD:12,316 VA TOTAL CALCULATED LOAD:12,316 VA TOTAL CALCULATED LOAD:12,316 VA uCZ_ <br /> TOTAL CALCULATEDAMPS:59A TOTAL CALCULATED AMPS:59A TOTAL CALCULATEDAMPS:59A G Q <br /> TOTALS: 12,013 12,316 TOTALS: 12,013 12,316 TOTALS: 12,013 12,316 ^1 <br /> NOTES: HARGIS ENGINEERS,INC. NOTES: HARGIS ENGINEERS,INC. NOTES: HARGIS ENGINEERS,INC. W <br /> 2. SEATTLEENUE,SUITE 600 1. 1201 THIRD AVENUE,SUITE 600 1. 1201 THIRDAVENUE,SUITE 600 <br /> 1. 1201 THIRD AV J Lf•1L/ VW! <br /> WA 98101 2. SEATTLE,WA 98101 2. SEATTLE,WA 98101 <br /> 3. 3. 3. W M <br /> 4. AXPH.(206)448-445 4. PH.AX((206)48-445 4. FAPH.X <br /> (206)448-445 w O <br /> 5. FAX.(206)4656650 5. FAX.(206)0454450 5. FAX.(206)4454450 <br /> PANEL SCHEDULE:05123/2022 E PANEL'P-5' PROJECT:Horizon ES Portable Resboom Replacement PANEL SCHEDULE:0512312022 E PANEL'P-8/P-7' PROJECT:Horizon ES Portable Restroom Replacement Z O <br /> CLASSIFICATION:NORMAL VOLTAGE:2081120V 10,3-WIRE SECTION:1011 CLASSIFICATION:NORMAL VOLTAGE:208/120V10,-IRE SECTION:1 OF O Q <br /> FED FROM:(E)DIST.PANEL'PDP' MAINS:1250 MAIN CIRCUIT BREAKER FED FROM:(E)DIST.PANEL'PDP' MAINS:20OA MAIN CIRCUIT BREAKER N U <br /> MOUNTING:FLUSH NEUTRAL:100%RATED MOUNTING:FLUSH NEUTRAL:100%RATED ILL! <br /> CKT BREAKER LOAD LOAD BREAKERITAW <br /> CKT BREAKER LOAD LOAD BREAKER CKT <br /> NOTE <br /> OT ITEM DESCRIPTION NO. AMP POLE (VA) 0 (VA) AMP POLE ITEM DESCRIPTION NOT NOT ITEM DESCRIPTION NO. AMP POLE (VA) 0 (VA) AMP POLE NO. ITEM DESCRIPTION NOT O <br /> UNIT VENTILATOR 1 60 2 4500 A 540 20 1 CEPTACLES HEAT PUMP 1 1 90 2 7257 A 7257 90 2 2 HEAT PUMP 2 W ^' <br /> 3 - - 4500 B 540 20 1 CEPTACLES 3 - - 7257 B 7257 - - 4 `V <br /> LIGHTING 5 20 1 1118 A 360 20 1 LIGHTING 5 20 1 894 A 20 1 6 SPACE -I <br /> 1 NAL PANEL 7 20 1 400 B 360 20 1 TA'B' RECEPTACLES 7 20 1 1440 B 1080 20 1 8 RECEPTACLES (yuiATVAMPLIFIER 9 20 1 480 A 500 20 1 IGATION CONTROLLER 1 RECEPTACLES 9 20 1 1080 A 1260 20 1 10 RECEPTACLES <br /> PACE 11 B ACE RECEPTACLES 11 20 1 1260 B 1260 20 1 12 RECEPTACLES <br /> PACE 13 A ACE PARE 13 20 1 A 20 1 14 SPARE <br /> PACE 15 B ACE PACE 15 20 1 B 20 1 1E SPACE <br /> PACE 17 A ACE PACE 1] 20 1 A 20 1 18 SPACE <br /> PAC19 B ACE PACE 19 20 1 B 20 1 20 SPACE <br /> PACE 21 - - A - - ACE <br /> PACE 23 B ACE <br /> REV. RELEASE DATE <br /> EPR SET 11/28/23 <br /> LOAD CALCULATIONS LOAD CALCULATIONS <br /> LOAD DESCRIPTION CONN.(VA) DEMAND FACTOR CALC.(VA) LOAD DESCRIPTION CONN.(VA) DEMAND FACTOR CALC.(VA) <br /> MISCELLANEOUS CONTINUOUS: - 125% - LOAD SUMMARY MISCELLANEOUS CONTINUOUS: - 125% - LOADSUMMARY <br /> EQUIPMENT&MISCELLANEOUS: 11180 100% 11180 EQUIPMENT&MISCELLANEOUS: 29028 700% 29028 <br /> LIGHTING: 1118 125% 1398 TOTAL LIGHTING: 894 125% 1118 TOTAL <br /> LARGEST MOTOR: - 125% - CONNECTEDLOAD AMPS LARGEST MOTOR: - 125% - CONNECTEDLOAD AMPS <br /> MOTORS: - 10016 - MOTORS: - 100% - <br /> RECEPTACLE: 1080 100% 1080 PHASEA: 7,498VA 62A RECEPTACLE: 7380 100% 7380 PHASEA: 17,748VA 148A <br /> RECEPTACLES OVER 10kVA: - 50% - RECEPTACLES OVER 10WA: - 50% - <br /> PHASE B: 5,880 VA 49A PHASE B: 19,554 VA 163 A <br /> TOTAL CALCULATED LOAD:13,650 VA TOTAL CALCULATED LOAD:37,526 VA <br /> m <br /> Q TOTAL CALCULATED AMPS:66A TOTAL CALCULATED AMPS:180A <br /> = TOTALS: 13,378 13,658 TOTALS: 37,302 37.526 <br /> 3 <br /> oNOTES: HARGIS ENGINEERS,INC. NOTES: HARGIS ENGINEERS,INC. PROJECT NO. 23202 <br /> Of 0 1 1.PROVIDE NEW CIRCUIT BREAKER IN EXISTING SPACE. 1201 THIRD AVENUE,SUITE 600 1. 1201T IRD AVENUE,SUITE 600 HARGIS PROJECT NO. 23202 <br /> Q 0 2. SEATTLE,WA98101 2. SEATTLE,WA98101 <br /> 3. 3. DRAWN BY AH <br /> W U 4. PH.(206)448-3376 4. PH.(206)448-3376 <br /> j aCHECKED BY MH <br /> 5. FAX.(206)4454450 5. FAX.(206)4454450 <br /> �m APPROVED BY MH <br /> SHEET TITLE <br /> ¢� <br /> $ry <br /> o ELECTRICAL <br /> PANELBOARD <br /> SCHEDULES <br /> wa <br /> �0 <br /> a SHEET NUMBER <br /> rw <br /> °w <br /> ai WE10.01 <br />