My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2024-02-29
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2024-02-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/29/2024 2:24:57 PM
Creation date
2/11/2024 11:26:57 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
187
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AWAS((((*))) <br />/1M?LIFIED WIRELESS SOLUTIONS, INC <br />1. ACCEPTANCE TEST PLAN <br />1.1. Equipment Setup <br />This section I intended to provide a guideline for the setup of the test equipment. This setup may <br />change based on the make and model number being used to perform tests. When conflicts arise <br />between this document and the manufacturers recommended testing procedures, the <br />manufacturers requirements shall be utilized. <br />• Spectrum analyzer with unity gain (0d13, frequency specific) dipole receive <br />antenna shall be used for acceptance testing. <br />• The test equipment shall have been calibrated within 1 year of the test date. <br />• Test equipment shall be allowed to stabilize in test environment prior to <br />calibration for a minimum of thirty minutes. Any change in temperature can void <br />the calibration. <br />• Signal generator must be connected to the Head end downlink (TX) interface via <br />tested and approved coaxial cabling and connectors. The control channel from <br />the base station can be used as a signal source as well. <br />• Verify that all remote units for the area under test are ON. <br />1.2. Acceptance Test Procedure <br />Acceptance test procedure. Where an emergency responder radio coverage system is required, <br />and upon completion of installation, the building owner shall have the radio system tested to <br />verify that two-way coverage on each floor of the building is not less than 90 percent. The test <br />procedure shall be conducted as follows: <br />• Each floor of the building shall be divided into a grid of 20 approximately equal <br />test areas. <br />• The test shall be conducted using a calibrated portable radio of the latest brand <br />and model used by the agency talking through the agency's radio <br />communications system. <br />• Failure of not more than two nonadjacent test areas shall not result in failure of <br />the test. <br />• In the event that three of the test areas fail the test, to be more statistically <br />accurate, the floor shall be permitted to be divided into 40 equal test areas. <br />Failure of not more than four nonadjacent test areas shall not result in failure of <br />the test. If the system fails the 40-area test, the system shall be altered to meet <br />the 90-percent coverage requirement. <br />• A test location approximately in the center of each test area shall be selected for <br />the test, with the radio enabled to verify two-way communications to and from the <br />outside of the building through the public agency's radio communications system. <br />Once the test location has been selected, that location shall represent the entire <br />test area. Failure in the selected test location shall be considered failure of that <br />test area. Additional test locations shall not be permitted. <br />Amplified Wireless Solutions, Inc. <br />6000 NE 88th St., Bldg C, Suite 107 <br />Vancouver, WA 98665 <br />
The URL can be used to link to this page
Your browser does not support the video tag.