My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1605 SE EVERETT MALL WAY WALMART 2024-02-29
>
Address Records
>
SE EVERETT MALL WAY
>
1605
>
WALMART
>
1605 SE EVERETT MALL WAY WALMART 2024-02-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/29/2024 2:24:57 PM
Creation date
2/11/2024 11:26:57 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1605
Tenant Name
WALMART
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
187
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AWAS(((((*)))) <br />/1M?LIFIED WIRELESS SOLUTIONS, INC <br />The gain values of all amplifiers shall be measured and the test measurement <br />results shall be kept on file with the building owner so that the measurements can <br />be verified during annual tests. In the event that the measurement results <br />become lost, the building owner shall be required to rerun the acceptance test to <br />reestablish the gain values. <br />As part of the installation a spectrum analyzer or other suitable test equipment <br />shall be utilized to ensure spurious oscillations are not being generated by the <br />subject signal booster. This test shall be conducted at the time of installation and <br />subsequent annual inspections. <br />1.3. Documentation <br />This section I intended to provide a guideline for the testing documentation. The guidelines listed <br />below may be changed to meet specific requirements of the project or the Authority Having <br />Jurisdiction (AHJ). <br />• Test frequency and power must be recorded corresponding to the date and time <br />of each site walk measurement. <br />• Test results shall be saved with frequency span +/- 20 MHz relative to the <br />center/measured frequency. <br />• Each floor of the building shall be divided into a grid of 20 approximately equal <br />test areas. Each grid will be labelled on the prints numbered 01-20 <br />• Test results shall be saved in native format with the file name indicating the floor, <br />grid number tested and an alphanumeric identifier if multiple tests are made in <br />the same grid: <br />o Example: The second test in Grid 15 on Floor 3 shall be labeled, FL3- <br />15-B. FL3 identifies it as the 3rd floor, 15 identifies Grid 15 and B <br />identifies it as the second test. <br />• Upon completion of testing all test results and prints shall be saved and <br />submitted in PDF format. <br />Amplified Wireless Solutions, Inc. <br />6000 NE 88th St., Bldg C, Suite 107 <br />Vancouver, WA 98665 <br />
The URL can be used to link to this page
Your browser does not support the video tag.