Laserfiche WebLink
Soniya Moon <br />Blue Moon Realty LLC <br />Plan Check Number: B2201-048, First Building Review <br />April 20, 2022 <br />2. The proposed project includes structural work. Structural drawings should be submitted that <br />include framing plans, sections, details, construction schedules, fastening schedules, materials <br />requirements, general notes, etc. The drawings should substantiate compliance with the <br />prescriptive requirements of the IRC. Where a structural design is performed per Section <br />R301.1.3, structural drawings and calculations should be prepared by a professional engineer <br />licensed in the state of Washington; the drawings and calculations should bear the seal and <br />signature of the engineer. See RCW Sections 18.43.010, 18.43.020, and 18.43.070 and IRC <br />Sections R106.1.1 and R301.1. <br />3. Please provide Foundation plans, sections, and/or details showing any new footings and any <br />below -grade walls. The foundation material(s) should be clearly specified. The plans should <br />specify the type, size, length, width, thickness, and height of all parts of the foundation. Clearly <br />indicate locations of all required hold downs. R106.1.1 <br />4. The plans appear to show basement retaining walls supporting more than 48 inches of <br />unbalanced backfill. Retaining wall details should be included in the drawings and calculations <br />substantiating the design should be submitted for review. See IRC Section R404.1.1. Note that <br />retaining walls supporting more than 6 feet of backfill height measured to the bottom of the <br />footing should include an additional seismic lateral earth pressure. IBC 1807.2.2 <br />5. See Details 4 and 5 on Sheet A11. A drainage system should be specified. See Section R405.1 <br />for more information. <br />6. See Detail 5 on Sheet A11. Plans should include notes for the construction of the window well <br />walls. R106.1.1 <br />This review has been performed for general compliance with the building codes as adopted and <br />amended by the state of Washington and the city of Everett. Corrections and comments made <br />during the review process do not relieve the project from compliance with code and permit <br />requirements. The designers -of -record are responsible for a complete design in accordance with <br />the laws of the state of Washington. <br />If you have any questions or require additional clarification, please contact us. <br />Respectfully, <br />Rakeeb Khan <br />Residential Plans Examiner <br />(425)257-7299 <br />rkhan@everettwa.gov <br />S:\RKhan\2022\B2201-048_R1.docx <br />(S 3200 Cedar Street <br />Everett, WA 98201 <br />© 425.257.8810 O <br />425.257.8857 fax <br />everetteps@everettwa.gov <br />everettwa.gov/perm its <br />Page 3 of 3 <br />