My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1318 75TH ST SE 2024-03-01
>
Address Records
>
75TH ST SE
>
1318
>
1318 75TH ST SE 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 3:57:39 PM
Creation date
2/13/2024 11:03:33 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
1318
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
312
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I Advanced Blower Door Test Company <br />425.870.1837 <br />Technician Name: Date: <br />Permit N: Age of House: <br />House address&lot#: 131`K ls^ %t. SC <br />City: E�ecr State: WA jZip Code: <br />Source (circle one):(VM1R5> ESTIMATED MEASURED <br />Blower Door Fan Location <br />-em rjAcsC <br />Ring (Circle one)) <br />OPEN <br />A <br />B <br />Other: <br />Weather Conditions: <br />Clear <br />Rain <br />ve a <br />Other: <br />Conditioned Floor Area: oqj�, <br />TEST RESULTS <br />Volume: <br />8.S Volume: <br />ACH: <br />ACH: a.a <br />CFM: <br />CFM: g31.3 <br />I certify that these blower door results are accurate and determined using standard industry protocol: <br />Company Name: <br />lAdvanced Blower Door Test Company <br />Technician Signature: <br />Date: <br />1D <br />) Dl ) 33 <br />R402.4.1 Testing -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 <br />ACH50. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). For this test only, the <br />volume of the home shall be the conditioned floor area on ft2 (2)multiplied by 8.5 feet (2.6m) Where required by the code <br />official, testing shall be conducted by an approved third party. A written report of the results shall be signed by the party <br />onducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetratioi <br />f the building thermal envelope. Once visual inspection has confirmed sealing (see Table R402.4.1.1), operable windows ai <br />doors manufactured by small business shall be permitted to be sealed off at the frame prior to the test. <br />During Testing: Exterior Windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the <br />intended weather stripping or other infiltration control measures; <br />_L.LDampers including exhaust, intake, makeup air, back <br />draft and flue shall be closed, but not sealed beyond intended infiltration control measures; 3.Llnterior doors, if installed at <br />the time of the test, shall be open. Access hatches to conditioned crawl spaces and conditioned attics shall be open; <br />Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed, sealed; 5AHeating and <br />cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the <br />time of the test, Shall be fully open. <br />Results shall be reported as Air Changes per Hour at 50 Pascals (ACH50) and shall be calculated as follows: <br />50 ACH = (CFM50 x 60)/Volume <br />Where: CFM50 = Blower door fan at 50 Pascal pressure difference <br />Volume =Conditioned floor area of housing unit x ceiling height. <br />
The URL can be used to link to this page
Your browser does not support the video tag.