Laserfiche WebLink
+ J <br /> • <br /> • <br /> NH-200H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- zone of supervised polarized Notification Appliances. Mounts <br /> sor. Ivory.B300-6-IV base included,FlashScan and CLIP mode. directly to a 4.0" (10.16 cm.) electrical box. NAC option requires <br /> Legacy Devices external 24 VDC to power notification appliances. <br /> FSP-851:Addressable low-profile photoelectric smoke detector. FRM-1: Addressable relay module containing two isolated sets of <br /> NP-100:Addressable low-profile photoelectric smoke detector. Form-C contacts,which operate as a DPDT switch. Mounts directly <br /> to a 4.0"(10.16 cm.)box,surface mount using the SMB500. <br /> FSP-851T: Addressable low-profile photoelectric smoke detector NC-100R:Addressable relay module containing two isolated sets of <br /> with thermal sensor. Form-C contacts,which operate as a DPDT switch. Mounts directly <br /> NP-100T:Addressable low-profile photoelectric smoke detector with to a 4.0"(10.16 cm.)box,surface mount using the SMB500. <br /> thermal sensor. NBG-12LX:Addressable manual pull station with interface module <br /> FSP-851R: Remote test capable addressable photoelectric smoke mounted inside. <br /> detector for use with DNR(W)duct detector housing. NOT-BG12LX:Addressable manual pull station with interface mod- <br /> NP-100R: Remote test capable addressable photoelectric smoke ule mounted inside. <br /> detector for use with DNR(W)duct detector housing. ISO-X:Fault Isolator Module. <br /> FST-851:Fast-response,low-profile heat detector. NI00-ISO:Fault Isolator Module. <br /> NH•100:Fast-response,low-profile heat detector. ISO-6:Six-fault isolator module.Mount one or two modules in a BB- <br /> FST-851R:Fast-response,low-profile heat detector with rate-of-rise XP cabinet(optional). Mount up to six modules on a CHS-6 chassis <br /> option. in a CAB-3/CAB-4 series cabinet. <br /> NH-100R: Fast-response, low-profile heat detector with rate-of-rise SMB500:Used to mount all modules except FMM-101/NMM-100P. <br /> option. NMM-100-10:Ten-input monitor module.Mount one or two modules <br /> FST-851H:Fast-response,low-profile heat detector that activates at in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 <br /> 190°F/88°C. chassis in a BB-6F cabinet. <br /> NH-100H: Fast-response,low-profile heat detector that activates at NZM-100-6:Six-zone interface module. Mount one or two modules <br /> 190°F/88°C. in a BB-XP cabinet(optional).Mount up to six modules on a CHS-6 <br /> FAPT-851:Addressable low-profile multi-sensor detector. chassis in a CAB-3/CAB-4 series cabinet. <br /> NP-A100:Addressable low-profile multi-sensor detector. SWIFT Wireless Devices <br /> B200S:Programmable,addressable sounder base. FWSG:Wireless Gateway <br /> B200SR:Addressable sounder base. FWD-200P:intelligent,wireless photo detector. <br /> DNR:lnnovairFiex low-flow non relay duct-detector housing.(Order FWH-200R0R135: LiteSpeed intelligent wireless rate of rise(135°) <br /> FSP-851 R,FSP-951 R,or NP-100R separately.) heat detector. <br /> DNRW: InnovairFlex low-flow non-relay duct-detector housing,with FWD-200ACCLIMATE:Wireless Acclimate Detector <br /> NEMA-4 rating. Watertight. (Order FSP-851R, FSP-951R, or FWH-200FIX135: intelligent wireless fixed-temperature (135°) heat <br /> NP-100R separately.) detector. <br /> Addressable Modules FW-MM:Intelligent wireless monitor module. <br /> FMM-1:Addressable Monitor Module for one zone of normally-open FW-RM:Intelligent wireless relay module. <br /> dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) NBG-12LW:Intelligent wireless pull station. <br /> box. Includes plastic cover plate and end-of-line resistor. Module WAV-RL,WAV-WL,WAV-CRL,WAV-CWL: Intelligent AV bases. <br /> may be configured for either a Style B(Class B)or Style D(Class A) W-USB: Wireless USB radio/antenna dongle that plugs into the <br /> IDC. USB port of a PC running SWIFT Tools. <br /> NMM-100:Addressable Monitor Module for one zone of normally- SWIFT Tools: Programming and diagnostic utility for the Wireless <br /> open dry-contact initiating devices. Mounts in standard 4.0" (10.16 Gateway and devices.Available for download from firelite.com. <br /> cm.)box. Includes plastic cover plate and end-of-line resistor. Mod NOTE: For more information on Compatible Addressable Devices for <br /> ule may be configured for either a Style B(Class B)or Style D(Class use with the Fire Warden-50X, see the following data sheets(document <br /> A)IDC. numbers): NP-200 Series (DN-60979), NH-200 Series (DN-60980), <br /> FDM-1:Dual Monitor Module.Same as NMM-100 except it provides FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 <br /> two Style B(Class B)only IDCs. Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), <br /> NDM-100: Dual Monitor Module. Same as NMM-100 except it pro- N100-lSO (DN-6994), NP-100 series (DN-6995), NH-100/NH-100R <br /> vides two Style B(Class B)only IDCs. (DN-6997), DNR/lnnovairFlex (DN-60424, DN-60429), NP A100 <br /> (DN-6998), NMM-100/NMM-100P/NDM-100/NZM-100 (DN-6999), <br /> FMM-101: Miniature version of NMM-100. Excludes LED and Style NC-100 (DN-7000), NC-100R (DN-60383), NMM-100-10 (DN-6990), <br /> D option.Connects with wire pigtails.May mount in device backbox. MM-1/FDM-1/FZM-1/FMM-101 (DN-6720), FCM-1/FRM-1 (DN-6724), <br /> NMM-100P:Miniature version of NMM-100.Excludes LED and Style NOT-BG12LX (DN-7001), NBG-12LX (DN-6726), and Fire Warden <br /> D option.Connects with wire pigtails.May mount in device backbox. SLC Manual (52304). <br /> FZM-1: Similar to NMM-100. Addressable Monitor Module for one ADDRESSABLE DEVICE ACCESSORIES <br /> zone of conventional two-wire detectors. Requires resettable 24 End-of-Line Resistor Assembly (R-47K and R-3.9K): The <br /> VDC power. Refer to the Device Compatibility Document for listed 47k ohm assembly supervises the FMM-1/NMM-100-10, FDM-1/ <br /> compatible devices and quantity limitation. NDM-100, FMM-101/NMM-100P, and FCM-1/NC-100 module cir- <br /> NZM-100:Similar to NMM-100.Addressable Monitor Module for one cults. The 3.9k ohm assembly supervises the XP6-MA/NZM-100-6 <br /> zone of conventional two-wire detectors. Requires resettable 24 module circuit.These resistors are included with each module. <br /> VDC power. Refer to the Device Compatibility Document for listed Power Supervision Relay: Supervises the power to 4-wire smoke <br /> compatible devices and quantity limitation. detectors and notification appliances. <br /> FCM-1: Addressable Control Module for one Style Y/Z (Class B/A) <br /> zone of supervised polarized Notification Appliances. Mounts Wiring Requirements <br /> directly to a 4.0" (10.16 cm.) electrical box. NAC option requires <br /> external 24 VDC to power notification appliances. While shielded wire is not required, it is recommended that all SLC <br /> NC-100:Addressable Control Module for one Style Y/Z(Class B/A) wiring be twisted-pair to minimize the effects of electrical interfer- <br /> ence.Refer to the panel manual for wiring details. <br /> DN-60955:C•7/16/2018--Page 3 of 4 <br />