Laserfiche WebLink
• Program Check automatically catches common errors not linked order R for red.) <br /> to any zone or input point N-ANN-I/O:LED Driver Module provides connections to a user sup- <br /> • OFFLINE PROGRAMMING: Create the entire program in your plied graphic annunciator.(See DN-7105.) <br /> office using FS-Tools,a Windows®-based software package,and N-ANN-LED: Annunciator Module provides three LEDs for each <br /> upload/download system programming locally. Offline program- zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. <br /> ming requires an ethernet connection. FS-Tools is available on (See DN-60242.) <br /> www.notifier.com. <br /> N-ANN-RLED: Provides alarm (red) indicators for up to 30 input <br /> User interface zones or addressable points.(See DN-60242.) <br /> LED INDICATORS N-ANN-RLY: Relay Module provides 10 programmable Form-C <br /> • Fire Alarm(red) CO Alarm(red) relays.Can be mounted inside the cabinet.(See DN-7107.) <br /> • AC Power(green) • Supervisory(yellow) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a <br /> connection for a serial or parallel printer.(See DN-7103.) <br /> • Trouble(yellow) • Ground fault(yellow) <br /> • Battery fault(yellow) • Disabled(yellow) <br /> ADDRESSABLE DEVICES <br /> • Maintenance(yellow) • Communication(yellow) FSP-951: Addressable low-profile photoelectric smoke detector. <br /> FlashScan only. <br /> • Alarm Silenced(yellow) • F1-F4 Programmable Function FSP-951-IV:Addressable low-profile photoelectric smoke detector. <br /> Keys(yellow) Ivory.FlashScan and CLIP mode. <br /> KEYPAD NP-200: Addressable low-profile photoelectric smoke detector. <br /> • 16 key alpha-numeric pad • Acknowledge B300-6 base included,FlashScan only. <br /> • Alarm Silence • Drill(Manual Evacuate) NP-200-IV: Addressable low-profile photoelectric smoke detector. <br /> Ivory,B300-6-IV base included.FlashScan and CLIP mode. <br /> • Four(4)programmable function keys• Reset(lamp test) FSP-951T: Addressable low-profile photoelectric smoke detector <br /> Product Line Information with thermal sensor.FlashScan only. <br /> FSP-951T-IV:Addressable low-profile photoelectric smoke detector <br /> NFW-50X: Addressable Fire Alarm Control Panel with one SLC with thermal sensor.Ivory.FlashScan and CLIP mode. <br /> loop. Includes main circuit board with display, pre-installed (POTS- NP-200T:Addressable low-profile photoelectric smoke detector with <br /> COM communicator, chassis with transformer, backbox with door, thermal sensor.B300-6 base included.FlashScan only. <br /> plastic bag containing screws,cables,key,etc. <br /> FS-Tools: Programming software for Windows®based PC cm- NP-200T-IV: Addressable low-profile photoelectric smoke detector <br /> puter.Available for download at www.notifier.com. with thermal sensor. Ivory,B300-6-IV base included.FlashScan and <br /> CELL-CAB-N/CELL-MOD:Optional GSM communicators. CLIP mode. <br /> (POTS-COM Dual technology (POTS and IP) communicator. FSP-951R: Remote test capable addressable photoelectric smoke <br /> (replacement board) detector for use with DNR(W) duct detector housing. FlashScan <br /> only. <br /> DP-ES-R:Optional dress panel for the NFW-50XR(red). FSP-951R-IV: Remote test capable addressable photoelectric <br /> DP-ES-B:Optional dress panel for NFW-50X(black). smoke detector for use with DNR(W) duct detector housing. Ivory. <br /> TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For FlashScan and CLIP mode. <br /> red,orderTR-CE.) NP-200R: Remote test capable addressable photoelectric smoke <br /> BB-XP:Optional cabinet for one or two modules. detector for use with DNR(W) duct detector housing. FlashScan <br /> BB-25: Optional cabinet for up to six modules mounted on CHS-6 only. <br /> chassis. NP-200R-IV:Remote test capable addressable photoelectric smoke <br /> BB-26:Battery backbox,holds up to two 25 AH batteries&CHG-75. detector for use with DNR(W)duct detector housing. Ivory, FlashS- <br /> NFS-LBB:Battery box,houses two 55 AH batteries can and CLIP mode. <br /> CHS-6:Chassis,mounts up to six multi-modules in a BB-25 cabinet. FST-951:Low-profile 135°F fixed thermal sensor.FlashScan only. <br /> CHG-75:Battery charger for lead-acid batteries with a rating of 25 to FST-951-IV: Low-profile 135°F fixed thermal sensor. Ivory. FlashS- <br /> 75 AH. can and CLIP mode. <br /> CHG-120: Remote battery charging system for lead-acid batteries NH-200: Low-profile 135°F fixed thermal sensor. B300-6 base <br /> with a rating of 55 to 120 AR. Requires additional NFS-LBB for included,FlashScan only. <br /> mounting. <br /> NOTE:CHG-120 or CHG-75 required for batteries larger than 18AH. NH-200-IV:Low profile 135°F fixed thermal sensor.Ivory.B300-6-IV <br /> base included,FlashScan and CLIP mode. <br /> BAT Series:Batteries,see data sheet DN-6933. FST-951 R: Low-profile, intelligent, rate-of-rise thermal sensor. <br /> PRN Series: UL listed compatible event printer. Uses tractor-fed FlashScan only. <br /> paper. FST-951 R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. <br /> OPTIONAL MODULES Ivory.FlashScan and CLIP mode. <br /> 4XTM Reverse Polarity Transmitter Module: Provides a super- NH-200R: Low-profile 135°F fixed thermal sensor. B300-6 base <br /> vised output for local energy municipal box transmitter, alarm and included,FlashScan only. <br /> trouble.Includes a disable switch and disable trouble LED. NH-200R-IV:Low-profile 135°F fixed thermal sensor. Ivory.B300-6- <br /> COMPATIBLE ANNUNCIATORS IV base included,FlashScan and CLIP mode. <br /> N-ANN-80:Remote,black LCD annunciator mimics the information FST-951H: Low-profile intelligent 190°F/88°C fixed thermal sensor. <br /> displayed on the FACP LCD display.Recommended wire type is un- FlashScan only. <br /> shielded. FST-951 H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- <br /> N-ANN-100: Remote LCD annunciator mimics the information dis- sor. Ivory. FlashScan and CLIP mode. <br /> played on the FACP LCD display. Recommended wire type is un- NH-200H: Low-profile intelligent 190°F/88°C fixed thermal sensor. <br /> shielded. For use in FM applications only. (Basic model is black; B300-6 base included,FlashScan only. <br /> Page 2 of 4—DN-60955:C•7/16/2018 <br />