DN-6999:E <br /> Monitor Modules ® NOTIFIER <br /> NM -i 00(A), NMM-100P(A), NZM-100(A), <br /> an NDM-100 A) for FireWarden Series by Honeywell <br /> Intelligent Addressable Devices <br /> General <br /> Four different monitor modules are available for Notifier's <br /> FireWarden Series intelligent control panels for a variety of • " <br /> applications. Monitor modules supervise a circuit of dry-con- ` <br /> tact input devices, such as conventional heat detectors and ® } <br /> pull stations, or monitor and power a circuit of two-wire ° d ale , <br /> smoke detectors(NZM-100(A)). COMIM <br /> NMM-100(A)is a standard-sized module(typically mounts to K Fs <br /> a 4" [10.16 cm] square box)that supervises either a Style D " <br /> 3 , <br /> (Class A) or Style B (Class B) circuit of dry-contact input g <br /> devices. -,....° <br /> NMM-100P(A) is a miniature monitor module a mere 1.3" <br /> (3.302 cm)H x 2.75"(6.985 cm)W x 0.65"(1.651 cm)D that <br /> supervises a Style B (Class B) circuit of dry-contact input <br /> devices. Its compact design allows the NMM-100P(A) to be " "M <br /> mounted in a single-gang box behind the device it monitors. <br /> NZM-100(A) is a standard-sized module that monitors and ° <br /> supervises compatible two-wire, 24 volt,smoke detectors on <br /> a Style D(Class A)or Style B(Class B)circuit. NMM-100(A)(Type H) <br /> NDM-100(A) is a standard-sized dual monitor module that <br /> monitors and supervises two independent two-wire Style B to monitor normally-open supervisory devices with special <br /> (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit <br /> separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B(Class B)or Style D(Class <br /> tems. A)Initiating Device Circuit.A 47K Ohm End-of-Line Resistor <br /> LiteSpeedTM is a communication protocol that greatly (provided) terminates the Style B circuit. No resistor is <br /> increases the speed of communication between analog Intel- required for supervision of the Style D circuit. <br /> ligent devices. Intelligent devices communicate in a grouped NMM-100(A)OPERATION <br /> fashion. If one of the devices within the group has new infor- <br /> mation,the panel CPU stops the group poll and concentrates Each NMM-100(A) uses one of the available module <br /> on single points. The net effect is response speed greater addresses on an SLC loop. It responds to regular polls from <br /> than five times that of other communication protocols. the control panel and reports its type and the status (open/ <br /> normal/short)of its Initiating Device Circuit(IDC).A flashing <br /> NMM-100[A) Monitor Module LED indicates that the module is in communication with the <br /> control panel. The LED latches steady on alarm (subject to <br /> • Built-in type identification automatically identifies this current limitations on the loop). <br /> device as a monitor module to the control panel. <br /> NMM-100(A)SPECIFICATIONS <br /> • Powered directly by two-wire SLC loop. No additional <br /> power required. Nominal operating voltage: 15 to 32 VDC. <br /> • High noise(EMF/RFI)immunity. Maximum current draw:5.0 mA(LED on). <br /> • SEMS screws with clamping plates for ease of wiring. Average operating current: 375 pA(LED flashing), 1 com- <br /> • Direct-dial entry of address: 01 —99 on FireWarden-100- munication every 5 seconds,47k EOL. <br /> 2,01—50 on FireWarden-50. Maximum IDC wiring resistance: 1500 Ohms. <br /> • LED flashes during normal operation and latches on Maximum IDC Voltage: 11 Volts. <br /> steady to indicate alarm. <br /> The NMM-100(A)Monitor Module is intended for use in Intel- EOL resistance:47K Ohms. <br /> ligent, two-wire systems, where the individual address of Temperature range:32°F to 120°F(0°C to 49°C). <br /> each module is selected using the built-in rotary switches. It <br /> provides either a two-wire or four-wire fault-tolerant Initiating Humidity range: 10%to 93%noncondensing. <br /> Device Circuit(IDC)for normally-open-contact fire alarm and Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x <br /> supervisory devices.The module has a panel-controlled LED 1.25" (3.175 cm)deep. Mounts to a 4" (10.16 cm)square x <br /> indicator. 2.125"(5.398 cm)deep box. <br /> NMM-100(A)APPLICATIONS <br /> Use to monitor a zone of four-wire smoke detectors, manual NMM-100P(A) Mini Monitor Module <br /> fire alarm pull stations,waterflow devices, or other normally- • Built-in type identification automatically identifies this <br /> open dry-contact alarm activation devices.May also be used device as a monitor module to the panel. <br /> DN-6999:E•07/30/2015—Page 1 of 4 <br />