My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1410 SEINER DR 2024-04-12
>
Address Records
>
SEINER DR
>
1410
>
1410 SEINER DR 2024-04-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2024 7:40:58 AM
Creation date
2/14/2024 9:41:31 AM
Metadata
Fields
Template:
Address Document
Street Name
SEINER DR
Street Number
1410
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Powered directly by two-wire SLC loop. No additional Wire length:6"(15.24 cm)minimum. <br /> power required. <br /> • High noise(EMF/RFI)immunity. NZM-100(A) Interface Module <br /> • Tinned,stripped leads for ease of wiring. • Supports compatible two-wire smoke detectors. <br /> • Direct-dial entry of address:01-99 on FireWarden-100-2, • Supervises IDC wiring and connection of external power <br /> 01 -50 on FireWarden-50. source. <br /> — --- - • High noise(EMF/RFI)immunity. <br /> Ett <br /> 3 1415 0 1 ADDRESS o 1 • SEMS screws with clamping plates for ease of wiring. <br /> f 1311 2 2 • Direct-dial entry entry of address:,01-99 on FireWarden- <br /> 3 �///P 4 LOOP �� 4 100-2,01 -50 on FireWarden-50. <br /> 10 5 5 • LED flashes during normal operation. <br /> 9 8 7 6 9 g 7 6 • LED latches steady to indicate alarm on command from <br /> TENS ONES control panel. <br /> The NZM-100(A) Interface Module is intended for use in <br /> intelligent, addressable systems, where the individual <br /> address of each module is selected using built-in rotary <br /> O W Q U switches. This module allows intelligent panels to interface <br /> J JO W Q and monitor two-wire conventional smoke detectors. It trans- <br /> Lu-1 mits the status (normal, open, or alarm) of one full zone of <br /> conventional detectors back to the control panel.All two-wire <br /> detectors being monitored must be UL compatible with the <br /> module. <br /> ,J NZM-100(A) APPLICATIONS <br /> The NMM-100P(A)Mini Monitor Module can be installed in a Use the NZM-100(A) to monitor a zone of two-wire smoke <br /> single-gang junction directly behind the monitored unit. Its detectors. The monitored circuit may be wired as an NFPA <br /> small size and light weight allow it to be installed without rigid Style B (Class B) or Style D (Class A) Initiating Device Cir- <br /> mounting. The NMM-100P(A) is intended for use in intelli- cuit.A 3.9 K Ohm End-of-Line Resistor(provided)terminates <br /> gent, two-wire systems where the individual address of each the end of the Style B or D (class B or A)circuit (maximum <br /> module is selected using rotary switches. It provides a two- IDC loop resistance is 25 Ohms). Install ELR across termi- <br /> wire initiating device circuit for normally-open-contact fire nals 8 and 9 for Style D application. <br /> alarm and security devices. NMM-100P(A) <br /> NZM-100(A)OPERATION <br /> NMM-100P(A)APPLICATIONS Each NZM-100(A) uses one of the available module <br /> Use to monitor a single device or a zone of four-wire smoke addresses on an SLC loop. It responds to regular polls from <br /> detectors, manual fire alarm pull stations,waterflow devices, the control panel and reports its type and the status (open/ <br /> or other normally-open dry-contact devices. May also be normal/short)of its Initiating Device Circuit(IDC).A flashing <br /> used to monitor normally-open supervisory devices with spe- LED indicates that the module is in communication with the <br /> cial supervisory indication at the control panel. Monitored cir- control panel. The LED latches steady on alarm (subject to <br /> cuit/device is wired as an NFPA Style B (Class B) Initiating current limitations on the loop). <br /> Device Circuit. A 47K Ohm End-of-Line Resistor (provided) <br /> terminates the circuit. NZM-100(A)SPECIFICATIONS <br /> NMM-100P(A) OPERATION Nominal operating voltage: 15 to 32 VDC. <br /> Each NMM-100P(A) uses one of the available module Maximum current draw:5.1 mA(LED on). <br /> addresses on an SLC loop. It responds to regular polls from Maximum IDC wiring resistance:25 Ohms. <br /> the control panel and reports its type and the status (open/ <br /> normal/short)of its Initiating Device Circuit(IDC). Average operating current: 270 pA, 1 communication and <br /> 1 LED flash every 5 seconds,3.9k eol. <br /> NMM-100P(A)SPECIFICATIONS <br /> EOL resistance:3.9K Ohms. <br /> Nominal operating voltage: 15 to 32 VDC. <br /> External supply voltage (between Terminals T10 and <br /> Average operating current: 350 pA, 1 communication T11): <br /> every 5 seconds, 47k EOL; 600 pA Max. (Communicating, <br /> IDC Shorted). • DC voltage:24 volts power limited. <br /> • <br /> Maximum IDC wiring resistance: 1500 Ohms. Ripple voltage:0.1 Vrms maximum. <br /> • Current:90 mA per module maximum. <br /> Maximum IDC Voltage: 11 Volts. <br /> Temperature range:32°F to 120°F(0°C to 49°C). <br /> Maximum IDC Current:450 pA. <br /> Humidity range: 10%to 93%noncondensing. <br /> EOL resistance:47K Ohms. <br /> Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x <br /> Temperature range: 32°F to 120°F(0°C to 49°C). 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm)square x <br /> Humidity range: 10%to 93%noncondensing. 2.125"(5.398 cm)deep box. <br /> Dimensions: 1.3"(3.302 cm)high x 2.75"(6.985 cm)wide x <br /> 0.65"(1.651 cm)deep. <br /> Page 2 of 4—DN-6999:E•07/30/2015 <br />
The URL can be used to link to this page
Your browser does not support the video tag.