Laserfiche WebLink
� ' *I NDM-100(A) Dual Monitor Module • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- <br /> The NDM-100(A) Dual Monitor Module is intended for use in 100);7300-0028:0237(NDM-100). <br /> intelligent,two-wire systems. It provides two independent two- • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); <br /> wire initiating device circuits(IDCs)at two separate,consecutive 227-03-E Vol.3(NDM-100). <br /> addresses.It is capable of monitoring normally open contact fire <br /> alarm and supervisory devices.The module has a single panel- Product Line Information <br /> controlled LED. <br /> NOTE:A"suix indicates ULC-listed model. <br /> NOTE: The NDM-100(A)provides two Style B(Class B)IDC cir- <br /> cuits ONLY. Style D(Class A) IDC circuits are NOT supported in NMM-100(A):Monitor module. <br /> any application. NMM-100P(A):Monitor module,miniature. <br /> NDM-100(A)SPECIFICATIONS NZM-100(A):Monitor module,two-wire detectors. <br /> Normal operating voltage range: 15 to 32 VDC. NDM-100(A): Monitor module, dual, two independent Class <br /> Maximum current draw:6.4 mA(LED on). B circuits. <br /> Average operating current:750 pA(LED flashing). SMB500:Optional surface-mount backbox. <br /> Maximum IDC wiring resistance: 1,500 Ohms. NOTE: See installation instructions and refer to the SLC Wiring <br /> Maximum IDC Voltage: 11 Volts. Manual,PN 52304. <br /> Maximum IDC Current:240 pA <br /> EOL resistance:47K Ohms. <br /> Temperature range:32°to 120°F(0°to 49°C). <br /> Humidity range: 10%to 93%(non-condensing). <br /> Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x <br /> 1.25"(3.175 cm)deep. Mounts to a 4" (10.16 cm)square x <br /> - 2.125"(5.398 cm)deep box. <br /> NDM-100(A)AUTOMATIC ADDRESSING <br /> The NDM-100(A)automatically assigns itself to two address- <br /> able points,starting with the original address.For example,if <br /> the NDM-100(A)is set to address"26",then it will automati- <br /> cally assign itself to addresses"26"and"27". <br /> NOTE:"Ones"addresses on the NDM-100(A)are 0, 2, 4, 6,or 8 <br /> only. Terminals 6 and 7 use the first address,and terminals 8 and <br /> 9 use the second address. <br /> QCAUTION: <br /> Avoid duplicating addresses on the system. <br /> Installation <br /> NMM-100(A),NZM-100(A),and NDM-100(A)modules mount <br /> directly to a standard 4" (10.16 cm) square, 2.125" (5.398 <br /> cm)deep, electrical box. They may also be mounted to the <br /> SMB500 surface-mount box. Mounting hardware and instal- <br /> lation instructions are provided with each module. All wiring <br /> must conform to applicable local codes,ordinances,and reg- <br /> ulations. These modules are intended for power-limited wir- <br /> ing only. <br /> The NMM-100P(A) module is intended to be wired and <br /> mounted without rigid connections inside a standard electri- <br /> cal box. All wiring must conform to applicable local codes, <br /> ordinances,and regulations. <br /> Agency Listings and Approvals <br /> In some cases,certain modules may not be listed by certain <br /> approval agencies,or listing may be in process.Consult fac- <br /> tory for latest listing status. <br /> • UL:S635. <br /> • ULC:S635. <br /> • FM Approved. <br /> DN-6999:E•07/30/2015—Page 3 of 4 <br />