My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1130 SE EVERETT MALL WAY MATTRESS FIRM 2024-04-02
>
Address Records
>
SE EVERETT MALL WAY
>
1130
>
MATTRESS FIRM
>
1130 SE EVERETT MALL WAY MATTRESS FIRM 2024-04-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2024 10:47:48 AM
Creation date
2/14/2024 10:08:42 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1130
Tenant Name
MATTRESS FIRM
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> 4 A" StarLink SLE-LTEV-CFB-PS <br /> NAPCO SLE-LTEV-CFB <br /> INTRODUCTION Commercial / Residential Fire <br /> The StarLink"Commercial/Residential Fire and Burglary alarm <br /> capture radio communicators are fully supervised,wireless digi- and Burglary Series Alarm <br /> tal two-way subscriber units supported by an extensive nation- <br /> wide wireless network. All models are compatible with most Communicators <br /> 12VDC alarm control panels (always adhere to the documenta- <br /> tion provided by the control panel manufacturer). Model SLE- Submittal Data Sheet <br /> LTEV-CFB is compatible with most 12 or 24VDC control panels. <br /> All can function as a backup to existing telephone lines, or as <br /> sole path primary communicators. In backup mode, all units SLE-LTEV-CFB-PS: Commercial/Residential Fire and Burglary <br /> will automatically switch the communication channel from the Radio in red metal housing with SLE-ULPS-R power supply and <br /> telephone line to the network when telephone line trouble is 16.5V/20VA transformer mounted inside housing <br /> detected. See WI2140 for programming information. <br /> The SLE-LTE Series radios use data-capture technology that cap- SLE-LTEV-CFB: Commercial / Residential Fire <br /> tures the alarm report from the control panel and transmits the and Burglary in red metal housing. Powered <br /> alarm signals to the SLE Control Center; the alarm signals are directly from control panel (no power supply, no <br /> then forwarded to ANY central station via Contact ID or Sur- transformer,rated 12/24VDC input) <br /> Gard System II via TCP/IP using standard line security. The SLE <br /> Control Center reports a trouble signal in the event that the <br /> network does not receive the expected supervision signal from <br /> the wireless communicator. <br /> For Commercial Burglary installations,under the armed condi- <br /> tion,any loss of communication must be treated as a Burglary Stir <br /> Alarm at the Central Station. <br /> STARLINK RADIO REPORTING PATH <br /> The diagram below shows the transmission path of a FIRE ALARM COMPATABILITY <br /> signal from the StarLink radio to the central station. These StarLink LTE Series models are compatible with most 12VDC <br /> 1.Signal from a Control Panel. alarm control panels equipped with a DACT that must transmit <br /> 2.StarLink radio receives the signal transmission (from central station reports in Contact ID or 4/2 central station formats. <br /> the TIP an RING wires); sends RF signal through the The control panel may also trigger communication events through <br /> GPRS network operator. the use of FACP dry contacts connecting the(3)radio inputs,capa- <br /> 3.Network Operator, part of the vendor system, a ble of transmitting (4) distinct alarm and trouble event reports to <br /> section of the cellular spectrum. the central station. The following features are included with mod- <br /> 4.SLE Network Operations Center, receives/routes data. els that include a SLE-ULPS-R power supply: <br /> 5.Central Station. • Power limited output to the StarLink radio PC board 12V input <br /> terminals <br /> iRFl���j • Battery connection red and black flying leads <br /> �a • Monitored battery charging and Active battery test circuits <br /> ((��" ' i))���� • StarLink radio trouble input (from StarLink radio PC board <br /> StarLink ' PGM1 terminal to detect StarLink radio trouble) <br /> Radio <br /> t •• Requires a sealed lead acid min 4AH/max 7AH battery for min <br /> - <br /> A 2) :is imum 24-hour standby time(max charge current 200mA). <br /> FACP — (3) A1/A. • Trouble relay output(C, N/O and N/C terminals)to wire to a <br /> (1) Network panel zone dedicated to"LTE Trouble" (dry contacts). Remove <br /> Operator jumper"J2"to isolate common from ground <br /> 1,I / • Green AC ON LED visible from the exterior housing <br /> i� • Yellow TROUBLE LED on PC board. Flashes signify: <br /> One flash: AC fail/brownout(2 hour delay) <br /> r—' Two flashes: Low battery <br /> CENTRAL �5� I�����) (4) Three flashes: Charging circuit trouble <br /> STATION StarLink Network Four flashes: StarLink radio trouble <br /> Operations Center <br /> NAPCO Security Technologies,Inc.,333 Bayview Ave,Amityville,NY 11701 (800)645-9445;Fax(631)789-9292 A733 11/18 <br /> \8\ b ) II <br />
The URL can be used to link to this page
Your browser does not support the video tag.