Laserfiche WebLink
• • <br /> 4 A" StarLink SLE-LTEV-CFB-PS <br /> NAPCO SLE-LTEV-CFB <br /> INTRODUCTION Commercial / Residential Fire <br /> The StarLink"Commercial/Residential Fire and Burglary alarm <br /> capture radio communicators are fully supervised,wireless digi- and Burglary Series Alarm <br /> tal two-way subscriber units supported by an extensive nation- <br /> wide wireless network. All models are compatible with most Communicators <br /> 12VDC alarm control panels (always adhere to the documenta- <br /> tion provided by the control panel manufacturer). Model SLE- Submittal Data Sheet <br /> LTEV-CFB is compatible with most 12 or 24VDC control panels. <br /> All can function as a backup to existing telephone lines, or as <br /> sole path primary communicators. In backup mode, all units SLE-LTEV-CFB-PS: Commercial/Residential Fire and Burglary <br /> will automatically switch the communication channel from the Radio in red metal housing with SLE-ULPS-R power supply and <br /> telephone line to the network when telephone line trouble is 16.5V/20VA transformer mounted inside housing <br /> detected. See WI2140 for programming information. <br /> The SLE-LTE Series radios use data-capture technology that cap- SLE-LTEV-CFB: Commercial / Residential Fire <br /> tures the alarm report from the control panel and transmits the and Burglary in red metal housing. Powered <br /> alarm signals to the SLE Control Center; the alarm signals are directly from control panel (no power supply, no <br /> then forwarded to ANY central station via Contact ID or Sur- transformer,rated 12/24VDC input) <br /> Gard System II via TCP/IP using standard line security. The SLE <br /> Control Center reports a trouble signal in the event that the <br /> network does not receive the expected supervision signal from <br /> the wireless communicator. <br /> For Commercial Burglary installations,under the armed condi- <br /> tion,any loss of communication must be treated as a Burglary Stir <br /> Alarm at the Central Station. <br /> STARLINK RADIO REPORTING PATH <br /> The diagram below shows the transmission path of a FIRE ALARM COMPATABILITY <br /> signal from the StarLink radio to the central station. These StarLink LTE Series models are compatible with most 12VDC <br /> 1.Signal from a Control Panel. alarm control panels equipped with a DACT that must transmit <br /> 2.StarLink radio receives the signal transmission (from central station reports in Contact ID or 4/2 central station formats. <br /> the TIP an RING wires); sends RF signal through the The control panel may also trigger communication events through <br /> GPRS network operator. the use of FACP dry contacts connecting the(3)radio inputs,capa- <br /> 3.Network Operator, part of the vendor system, a ble of transmitting (4) distinct alarm and trouble event reports to <br /> section of the cellular spectrum. the central station. The following features are included with mod- <br /> 4.SLE Network Operations Center, receives/routes data. els that include a SLE-ULPS-R power supply: <br /> 5.Central Station. • Power limited output to the StarLink radio PC board 12V input <br /> terminals <br /> iRFl���j • Battery connection red and black flying leads <br /> �a • Monitored battery charging and Active battery test circuits <br /> ((��" ' i))���� • StarLink radio trouble input (from StarLink radio PC board <br /> StarLink ' PGM1 terminal to detect StarLink radio trouble) <br /> Radio <br /> t •• Requires a sealed lead acid min 4AH/max 7AH battery for min <br /> - <br /> A 2) :is imum 24-hour standby time(max charge current 200mA). <br /> FACP — (3) A1/A. • Trouble relay output(C, N/O and N/C terminals)to wire to a <br /> (1) Network panel zone dedicated to"LTE Trouble" (dry contacts). Remove <br /> Operator jumper"J2"to isolate common from ground <br /> 1,I / • Green AC ON LED visible from the exterior housing <br /> i� • Yellow TROUBLE LED on PC board. Flashes signify: <br /> One flash: AC fail/brownout(2 hour delay) <br /> r—' Two flashes: Low battery <br /> CENTRAL �5� I�����) (4) Three flashes: Charging circuit trouble <br /> STATION StarLink Network Four flashes: StarLink radio trouble <br /> Operations Center <br /> NAPCO Security Technologies,Inc.,333 Bayview Ave,Amityville,NY 11701 (800)645-9445;Fax(631)789-9292 A733 11/18 <br /> \8\ b ) II <br />