• • <br /> The housing-mounted transformer (when provided) is mounted <br /> inside its own housing compartment with a replaceable UL • Input Current:150mA maximum <br /> Listed .5A fast blow primary fuse. 120VAC connections are to be • Maximum Charging Current: 200mA <br /> made by a licensed electrician using suitable connectors,in accord- Electrical Ratings for+12V <br /> ance with N.E.C.and local code requirements. For Models without Power Supply* <br /> • Input Voltage: 10-15VDC (power-limited output from Listed <br /> ADDITIONAL COMPONENTS control panel). Note: Model SLE-LTEV-CFB is rated 10-25VDC <br /> input. <br /> In addition to the models listed above, the following sub- • Input Current for SLE-LTEV-CFB: 10V=90mA, 12V = 71mA, <br /> assemblies are available: 25V=68mA,with peak RF transmission current of 200mA. <br /> SLE-ULPS-R - Power Supply. Required for installations where the Electrical Ratings for the IN 1 Burg/Fire Input: <br /> control panel cannot provide the 71mA of Auxiliary power re • Input Voltage: 9-15VDC. Note: Model SLE-LTEV-CFB is rated <br /> quired to operate the StarLink radio. Uses a standard 4AH/12V <br /> minimum(7AH maximum)rechargeable battery to provide radio 9-25VDC input. <br /> standby power. Requires connection to either the model NAP- • Maximum Input Current: Up to 2mA from FACP NAC circuit <br /> CO TRF12/T123 (16.5V/20VA) external plug-in transformer or Electrical Ratings for IN 2 and IN 3: <br /> the chassis-mounted 16.5VAC/20VA transformer affixed inside • Maximum Loop Voltage: 15VDC. Note: Model SLE-LTEV-CFB <br /> the housing(see wiring diagrams further in this manual). Note: is rated max 25VDC input. <br /> For models without the SLE-ULPS-R,connect the radio terminals • Maximum Loop Current: 1.2mA <br /> 1 and 2 to the control panel Aux Power terminals (observing • End of Line Resistor(EOLR)Value: 10K(2 req'd) <br /> polarity). Electrical Ratings for 3 PGM Outputs: <br /> SLE-DLCBL- Download Cable,6 feet • Open Collector Outputs: Maximum Voltage 3V when active; <br /> SLE-ANTEXT30-Extended antenna with 30 feet of cable 15V maximum when not active. Note: Model SLE-LTEV-CFB is <br /> SLE-ANTEXT50-Extended antenna with 50 feet of cable rated max 25VDC output. <br /> SLE-ANTEXT75-Extended antenna with 75 feet of cable • Maximum PGM Sink Current: 50mA (up to 15VDC), 25mA <br /> (Any suitable external cellular antenna is permitted by UL). Al- (15.1VDC-25VDC) <br /> ways follow the manufacturer's installation instructions. Note: Physical(W x H x D) <br /> Antennas are not Listed by UL. For LTE radios where an External • Metal Housing: 111A x 9%:x 31/2'(29.2 x 24.1 x 8.9cm) <br /> Antenna needs to be installed outside of the room in which the • Mounting: Metal housing includes two keyhole slots for wall <br /> radio is installed (maximum 30 meters (98 feet) in Residential mounting <br /> applications), please use RF Transmitter Board 9SLELTEEXAPSLD <br /> available from our Customer Service Department, if not provid Environmental <br /> ed. The 9SLELTEEXAPSLD is identified by"two red dots"located • Operating Temperature: 0°C 49°C(32°F 120°F) <br /> on the lower right corner of the board. See WI2239 included • Humidity: Maximum 93%Non Condensing <br /> with the 9SLELTEEXAPSLD for the simple installation procedure. • Indoor/dry location use only <br /> GEM-Tamperkit -Tamper switches and screws to protect metal <br /> housing <br /> AGENCY LISTINGS <br /> SPECIFICATIONS • UL 864 Standard For Control Units and Accessories For Fire Alarm <br /> The following specifications apply to all StarLink radio models Systems,10th Edition <br /> • UL 1610 Standard For Central-Station Burglar-Alarm Units <br /> unless otherwise stated: • UL 985 Standard For Household Fire Warning System Units <br /> Electrical Ratings for 120VAC,60Hz • UL 1023 Standard For Household Burglar-Alarm System Units <br /> For Models with Power Supply <br /> • Input Voltage: 120VAC nominal LTEV models are Verizon Network Certified <br /> NOTICE TO AUTHORITIES HAVING JURISDICTION, USERS, INSTALLERS, <br /> DEALERS, AND OTHER AFFECTED PARTIES <br /> FIRE PROGRAMMING OPTION PERMITTED IN AVAILABLE SETTINGS REQUIRED UL 864 SETTINGS <br /> UL864?(YIN) <br /> Disabled(Jumper 1 installed). Also required for Commercial/Burglary <br /> Unattended Remote Downloading No Enable/Disable installations. Note: See the Installation Instructions section <br /> "Configuration Download I Firmware Updates"for jumper instructions. <br /> IN2 and IN3 Unsupervised No Supervised/Unsuper- Supervised(Jumpers 4 and 5 installed) <br /> vised <br /> Radio Path Supervision No 200 seconds,5 minutes, 200 seconds(UL 864/UL 1610),5 minutes(UL 864 9th edition),60 <br /> 60 minutes,7 days minutes(UL 864 10th edition),7 days(UL 985/UL 1023) <br /> *For Commercial Fire installations,a UL Listed Fire Alarm regulated power supply or FACP regulated auxiliary output is required. <br /> \ ill\ <br />