Laserfiche WebLink
StarLink SLE-LTEVI-CFBPS & SLE-LTEAI-CFBPS <br /> PJAPCO SLE-LTEVI-CFB & SLE-LTEAI-CFB <br /> INTRODUCTION Commercial / Residential Fire Series <br /> The StarLink SLEATEVI-CFBPS- SLEATEAI-CFBPS, SEEATEW Dual Path Alarm Communicators <br /> CFO and SLE-LTEAI{FB Dual Path Commercial/Residential Fire <br /> alarm capture radio IP communicators are fully supervised, Submittal Data Sheet <br /> wireless digital two-way subscriber units. All models are com- <br /> patible with most 12/24VDC alarm control panels(always ad- <br /> here to the documentation provided by the control panel man- <br /> ufa(,turer). Three CurnrnwucatOri are fOf ux as the pre—ary <br /> means of communication with the central station and do not SLE-LTEVI-CFBPS & SLE-LTEAI-CFBPS Commercial / <br /> have backup mode capability. See W12140 for programming Residential Fire LTE Radio TCP/IP Communicators in red <br /> Information. metal housing with SLE-ULPS-R power supply and 16.SV/ <br /> The LTE Series radios use data capture technology that cap- 20VA transformer mounted inside <br /> tures the alarm report from the control panel and transmits the housing <br /> alarm signals to the Network Operations Center,the alarm sig- SLE-LTEVI-CFB & SLE-LTEAI- <br /> nals are then forwarded to ANY central station via Contact ID or CFB. Commercial/Residential Fire <br /> 4/2 central station formats. The radios can also report to a LTE Radio-TCP/IP Communicators in <br /> Sur-Gard System a Central station receiver via TCP/IP using red metal housing. Powered direct- <br /> standard line security- The Network Operations Center reports <br /> ly from Control panel (n0 power <br /> a trouble signal in the event that the network does not receive supply,no transformer,rated nomr <br /> the expected supervision Signal from the wireless communica- nal 12/24VDC input) <br /> tor <br /> FIREALARM COMPATIBILITY <br /> StarLink LTE Series models are Compatible with any FRCP <br /> equipped with a DACT that must transmit central station reports <br /> in Contact ID or 4/2 central station formats. The control panel <br /> may also trigger communication events through the use of FACP <br /> dry contacts connecting the (3) radio inputs, capable of trans <br /> - <br /> STARLINK RADIO REPORTING PATH mitting(4)distinct alarm and trouble event reports to the central <br /> The diagram below shows the transmission path of a station. <br /> signal from the StarLink radio to the central station. The following features are included. <br /> I-Signal from a Control Panel. <br /> 2.StarLink radio receives the signal transmission (from • Power limited output to the StarLink radio PC board 12V input <br /> the TIP an RING wires): sends RF signal through the terminals <br /> GPRS network operator. • Battery connection red and black flying leads <br /> 3 Network Operator, part of the vendor system, a • Monitored battery charging and Active battery test Circuits <br /> section of the cellular spectrum. a Requires a sealed lead acid min 4AH/max 7AH battery for <br /> 4 Network Operations Center,receives/routes data. minimum 24 hour standby time(max charge current 200niA). <br /> 5 Central Station • Trouble relay output IC,N/O and N/C terminals)to wire to a <br /> Nr OAr4 panel zone dedicated to"GSM Trouble- (dry contacts)- Re- <br /> m ove Iumper-12"isolate relay OUT1 common from ground <br /> • Green AC ON LED visible from the exterior housing <br /> ~ ((11l I 11)I • Yellow TROUBLE LED on PC board. Flashes signify <br /> sr,.i.ik One flash.AC fail/brownout(2 hour delay) <br /> '�^ Two flashes'Low battery <br /> 2) 3 Three flashes:Charging circuit trouble <br /> FACP 1 Four flashes.Startulk radio trouble <br /> 1� NT'_' The housing-mounted transformer(when provided)is mounted <br /> O—mo, inside its own housing compartment with a replaceable UL <br /> I� Listed.5A fast blow primary fuse. 120VAC connections are to be <br /> f'jrt1 made by a licensed electrician using suitable connectors, in ao <br /> �' cordance with N-E-C.and local Code requirements. <br /> CENTMI ADDITIONAL COMPONENTS <br /> STATION )rHnk IN-1k <br /> orx.,eor..c— In addition to the models listed above,the following accessories <br /> MAPCO Security Technologies.Inc..333 Bayview Ave.Amityville,NY 11701(800)645-9445:Fax(631)789-9292 A755A lU19 <br />