Laserfiche WebLink
SD100 I 6.7L 1100 kW GENERAL ( INDUSTRIAL <br /> INDUSTRIAL DIESEL GENERATOR SET <br /> EPA Certified Stationary Emergency <br /> OPERATING DATA <br /> POWER RATINGS <br /> Standby <br /> Single-Phase 120/240 VAC @1.Opt 100 kW Amps: 417 <br /> Three-Phase 120/208 VAC @0.8pf 100 kW Amps: 347 <br /> Three-Phase 120/240 VAC @0.8pf 100 kW Amps: 301 <br /> Three-Phase 277/480 VAC @0.8pf 100 kW Amps: 150 <br /> Three-Phase 346/600 VAC @0.8pf 100 kW Amps: 120 <br /> STARTING CAPABILITIES (sKVA) <br /> sKVA vs.Voltage Dip <br /> 480 VAC 208/240 VAC <br /> Alternator kW 10% 15% 20% 25% 30% 35% 10% 15% 20% 25% 30% 35% <br /> Standard 100 79 118 157 197 236 200 59 89 118 148 177 206 <br /> Upsize1 130 116 174 323 290 348 406 87 131 174 218 261 305 <br /> Upsize 2 150 133 199 265 332 398 464 100 149 199 249 299 348 <br /> Upsize 3 200 187 280 373 467 560 653 140 210 280 350 420 490 <br /> FUEL CONSUMPTION RATES* <br /> Diesel-gal/hr(I/hr) <br /> Fuel Pump Lift-ft(m) Percent Load Standby <br /> 3(1) 25% 2.2(8.3) <br /> 50% 4.2(15.9) <br /> Total Fuel Pump Flow(Combustion+ Return) 75% 5.9(22.3) <br /> 29.1 gal/hr 100% 7.3(27.6) <br /> *Fuel supply installation must accommodate fuel consumption rates at 100%load. <br /> COOLING <br /> Standby <br /> Coolant Flow per Minute gal/min(I/min) 44.6(168.8) <br /> Coolant System Capacity gal(L) 5.65(21.4) <br /> Heat Rejection to Coolant BTU/hr 269,130 <br /> Inlet Air cfm(ms/hr) 6360(180) <br /> Max.Operating Radiator Air Temp F°(C°) 122(50) <br /> Max.Ambient Temperature(before derate) F°(C°) 110(43.3) <br /> Maximum Radiator Backpressure in H2O 0.5 <br /> COMBUSTION AIR REQUIREMENTS <br /> Standby <br /> Flow at Rated Power cfm(m';min) 325(9.2) <br /> ENGINE EXHAUST <br /> Standby Standby <br /> Rated Engine Speed rpm 1800 Exhaust Flow(Rated Output) cfm(m3/min) 1022(28.94) w <br /> Horsepower at Rated kW"* hp 152 Max.Backpressure(Post Silencer) inHg(Kpa) 1.5(5.1) ti <br /> Piston Speed ft/min(m/min) 1559(475) Exhaust Temp(Rated Output) °F(°C) 885(474) w <br /> BMEP psi 165 Exhaust Outlet Size(Open Set) mm(in) 101.6(4) ti <br /> **RRter to"Emissions Data Sheet"for maximum bnP for EPA and SCAM)permitting purposes <br /> Deration—Operational characteristics consider maximum ambient conditions.Derate factors may apply under atypical site conditions. 5 Of s <br /> Please consult a Generac Power Systems Industrial Dealer for additional details.All performance ratings in accordance with 1503046,BS5514,1S08528 <br /> and DIN6271 standards. <br />