Laserfiche WebLink
• <br /> December 2008 Section 2 System Components Page 2-9 <br /> • Amerex Restaurant Fire Suppression System (EX 46.58) <br /> JOB LINKS <br /> Four temperature ratings of the Job Links are available. They are <br /> • constructed of two metal struts held intension by a small, glass bulb that �� <br /> ruptures at the appropriate temperature rating. The detector bracket (,�„ / -- .\ <br /> • (P/N 12508) will support either the Globe Type 'K' fusible links or the 1 <br /> • Job links, and the same detector limitations apply for both types of i � <br /> detector. <br /> • Response Max.Ambient <br /> • Part No. Type Link Rating Temperature <br /> 16226 Quick 286°F 141°C 225°F 107°C Job Quick Response Link <br /> • 16227 Quick 360°F 182°C 300°F 149°C Load Limit: 1 to 55 lb. <br /> • 16445 Quick 450°F 232°C 375°F 191°C <br /> • 16446 Quick 500°F 260°C 425°F 218°C <br /> • FUSIBLE LINKS EXPOSURE LIMIT <br /> Part Link Max.Ambient <br /> • Four temperature ratings of fusible links are available. No. Rating Temperature <br /> • They are of the electric solder type link which will melt at 12326 212°F 100°C 150°F 66°C <br /> a predetermined temperature allowing the two halves of 12327 280°F 138°C 225°F 107°C <br /> • the link to separate. 12328 360°F 182°C 300°F 149°C <br /> 12329 450°F 232°C 375°F 191°C <br /> • ,, c, ,,, <br /> (1 1 J l"l(( Temperature and year of manufacture <br /> �j <- o Uh. ,/ are stamped on each link. <br /> N �, JI % <br /> • Globe Type"K" <br /> • Load Limit: Maximum Load-50 lbs. (22.68 Kg) <br /> Minimum Load -3 lbs. (1.37 Kg)1 di 93 <br /> •.., ` CONDUIT OFFSET (P/N 12507) <br /> Ask <br /> • The conduit offset is used to allow a smooth transition for cable runs <br /> into or out of the MRM, MRM II & PRM without using pulley elbows. It <br /> • may be used with the detection network, manual pull stations or <br /> mechanical gas valve actuation network. The use of this device does <br /> not reduce the maximum number of corner pulleys allowed in the <br /> • system. THE CONDUIT OFFSET MAY ONLY BE ATTACHED TO tee' <br /> • THE ENCLOSURE OF EITHER THE MRM, MRM II OR THE PRM. <br /> •' FUSIBLE LINK TERMINATION KIT(PN 17515) QTY. DESCRIPTION. <br /> • The kit consists of four major components, their part 1 EMT CONDUIT CONNECTOR 1/2" <br /> numbers and quantities per kit are provided in the 1 CABLE SEG.-MRM TO 1°' LINK-30 FEET <br /> • table. The kit contains the necessary cable segments I CABLE SEG.-LINK TO TERMINATION <br /> and hardware for the beginning and end termination of <br /> • the Linear Fusible Link Detection network. 1 HANDY BOX-%2 CONDUIT BOX <br /> • MRM TO 15T LINK <br /> • = _: � � LINK TO TERMINATION <br /> — - <br /> III CABLE SEGMENT- LINK TO LINK - -- 24"/12"CENTERS <br /> • <br /> PN17354-24" CENTERS -='�, ! " <br /> • <br /> PN19155 - 12" CENTERS . -: 7. <br /> The Link to Link cable segment PN17354 insures that the ti LINK TO LINK <br /> .-.- links in the linear fusible link detection system are spaced at the maximum 24"centers to center distance. <br /> • The Link to Link cable segment PN19155 places links 12"apart center to center. It will assist in locating links <br /> in the hood duct opening when the two ducts are an odd distance apart. <br /> • <br />