My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-233 2024-03-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-233
>
3003 W CASINO RD BLDG 45-233 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 9:37:53 AM
Creation date
2/14/2024 11:20:49 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-233
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E) POTTER AFC-1 00 <br /> The Symbol of Protection Fire Alarm Control Panel <br /> SLC Features RA-6500R(F)—4 x 40 LCD annunciator with a key pad in a locked <br /> The Potter protocol is a digital protocol with a proven design for metal enclosure.Flush mount version available. <br /> reliability and noise immunity.The system does not require special LED-16(F)—16 LED annunciator with common indicators in a <br /> cable or conductors for connection of the Signaling Line Circuit locked metal enclosure.Flush mount version available. <br /> as long as the cable is compliant with NFPA 70 and NFPA 72. PSN-1000(E)—10 amp,remote intelligent power supply with <br /> The system allows for Class A or Class B installations as well as 6 NACs,2 I/Os and a P-Link repeater.This panel is listed in <br /> "T-Taps",with a max wiring distance of 10,000 Ft. conjunction with the AFC-100 as releasing circuits. <br /> CA-6075—Class A convertor that converts the SLC,NACs and <br /> Sensor Features P-Link connection <br /> The sensors through the fire alarm control panel provide a real UD-1000—UL listed,Dual line telephone alarm communicator <br /> time status as to the condition of the system.The smoke detector DRV-50—LED driver expander,used to connect up to 50 LEDs in a <br /> sensitivity,heat detector temperature level and drift compensation graphic display <br /> are all programmable options.The system also allows for a day/night FCB-1000—Fire communication bridge,provides remote mounting <br /> mode where the panel automatically adjusts the sensitivity depending of the Ethernet connection <br /> on the time of day.To assist in the reduction of false alarms,the FIB-1000—Fiber interface module,used to extend P-Link to multi- <br /> smoke detectors also have a maintenance warning that sends a trouble mode fiber(2 required) <br /> signal when a detector is dirty to the point that it can no longer <br /> maintain the programmed sensitivity. RLI'-5—Relay module,provides 5 form C relay contacts rated at 3.0 <br /> amps 24VDC/125AC <br /> User Interface SPG-1000—Serial parallel gateway,allows for the connection to a <br /> The fire alarm control panel has a 2 x 16 LCD display to provide serial or parallel printer <br /> information to the system status.The keypad has navigation keys The FIB-1000,FCB-1000 and the SPG-1000 may be installed in the <br /> to allow manipulation of the Menu on board the panel.The panel is stacker bracket or ordered with the optional rack mount enclosure. <br /> shipped standard with the following LEDs: MC-1000 Multi-Connect allows up to sixty-three AFC series panels <br /> • AC Power-Green to share a single reporting technology. <br /> • Alarm-Red IDC-6—Initiating device circuit provides 6 programmable inputs <br /> • Earth Fault-Amber AE-2—Two card expansion cabinet <br /> • Supervisory-Amber AE-8—Eight card expansion cabinet <br /> AE-14—Fourteen card expansion cabinet <br /> • Silenced-Amber <br /> Ethernet/I.P. Connection <br /> • Trouble-Amber The AFC-100 is shipped standard with an Ethernet connection. <br /> • Pre-Release-Amber This connection is the programming port and may be connected <br /> • Release-Red to a building Wide Area Network(WAN)or Local Area Network <br /> (LAN).Once connected to the Internet,the panel may be selectively <br /> The common buttons include a Silence,Reset,Acknowledge,and programmed to e-mail alarm conditions,trouble conditions, <br /> Drill.All of the buttons are accessible once the locked door is supervisory conditions,test,Event History and detector status.An <br /> opened. e-mail may be sent to the panel and the panel will e-mail the event <br /> P-Link history,detector status,configuration file or server status to an <br /> authorized E-mail account.In addition,reminders may be set to send <br /> The AFC-100 has a proprietary communication protocol that an e-mail for service,testing or other conditions. <br /> communicates through a RS-485 connection to field devices.Up <br /> to 32 devices may be connected to a single P-Link connection.The In addition,the Ethernet connection is UL listed as an IP <br /> P-Link includes the communication terminals and regulated 24 VDC communicator.The IP communicator is listed to report to the UL <br /> connection for the field devices.The field devices may be any of the listed Sur-Gard III IP receiver.The IP communicator replaces the <br /> following: traditional less reliable alarm communicator transmitter that utilized <br /> PAD100-SLCE-Analog/Addressable loop expansion module telephone lines.The IP communicator is an active method of <br /> SLOE-127-Nohmi addressable loop expansion module for retrofit connection and communication to the monitoring station. <br /> applications. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830134-REVD 3/19 PAGE 3 OF 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.