My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-233 2024-03-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-233
>
3003 W CASINO RD BLDG 45-233 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 9:37:53 AM
Creation date
2/14/2024 11:20:49 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-233
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E) POTTER PAD200-PD <br /> The Symbol of Protection Photoelectric Smoke Sensor <br /> Features <br /> • UL 268 7th Edition <br /> • Low profile,less than 2 inches with the base p <br /> • Wide selectable sensitivity range of 1.0 to 3.7%/foot <br /> • Sensor communicates sensitivity to control panel <br /> • UL listed smoke calibration and sensitivity <br /> • Optional locking tab to prevent unwanted removal <br /> • Simple DIP switch address setting,no programming tool <br /> required <br /> • LED alarm indicator <br /> • Product includes a 5 year warranty <br /> • UUKL Listed for Smoke Control O <br /> UL <br /> LISTED <br /> Description Technical Specifications <br /> The Photoelectric Smoke Sensor is a listed Analog Addressable smoke Operating Voltage 24 VDC <br /> sensor compatible with fire alarm control panels that utilize the Potter <br /> Addressable Device(PAD)protocol.The PAD200-PD is a low profile Detector Current Draw 300 gA <br /> smoke sensor with a wide sensitivity range.The sensor and base(not Alarm indicator 1 LED <br /> included)are made of a durable plastic in an off-white color to blend Alarm set-point range 1.0 to 3.7%/ft 3.6-12%/m <br /> in with the ceiling. <br /> n/o Installation temperature 32 to 120°F/ 0 to 49°C <br /> The PAD200-PD has a sensitivity range of 1.0 to 3.7 per foot and range <br /> is UL. The PAD200-PD features drift compensation and has built in <br /> dirty detector warning as well as. The PAD200-PD and the control Operating relative 0%to 93%(Non-condensing) <br /> panel communicate over a proven and robust digital communication humidity range <br /> path and the system analyzes the information at the particular device. Start-up time Max. 1 sec. <br /> The total polling speed is less than five(5)seconds,well under the UL Maximum number of <br /> requirements. addresses per loop 127 <br /> The sensor is compatible with any of the PAD series sensor bases and Maximum number of <br /> simply twists on. The PAD200-PD is addressed using DIP switches lighted indicators in 30 <br /> in the rear of the sensor and can be easily programmed in the field alarm per loop. <br /> without special tools. <br /> Color Eggshell White <br /> Setting the Address Weight(without base) 101g(3.56oz) <br /> Each addressable device on the SLC loop must have a unique address Dimensions(without Height: 1.35 in(34mm) <br /> from 1 to 127 to function properly. The address is set using DIP base) Diameter:3.93 in(100 mm) <br /> switches. <br /> Before connecting a device to the SLC loop, take the following <br /> precautions to prevent potential damage to SLC or device.Verify the <br /> following: <br /> 1. Power to the device is removed <br /> 2. Field wiring is correctly installed. <br /> 3. Field wiring has no open or short circuits. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830172-REV A 5/21 PAGE 1 OF 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.