Laserfiche WebLink
(E) POTTER PAD200-PD <br /> The Symbol of Protection Photoelectric Smoke Sensor <br /> Air Velocity Ratings <br /> The PAD200-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. <br /> The system has a maximum of 30 LEDs that can be turned on simultaneously.If the system already has 30 LEDs on,the PAD200-PD will operate even <br /> though the LED may not illuminate. <br /> Operation <br /> The PAD200-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel. <br /> The unit communicates with the control panel as it is polled.The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is <br /> in an active status.The polling LED can be turned off if desired for less conspicuous operation. <br /> The PAD200-PD with the PAD 100-4DB or PAD 100-6DB has a low profile of less than two(2)inches to blend into the surrounding environment.The <br /> sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. <br /> Sensor Sensitivity <br /> The PAD200-PD and the compatible control panel work in tandem to keep the sensitivity consistent.As the sensor is installed over time,the sensor <br /> compensates for the dirt in the unit until it is out of range.At that time,the panel will indicate a dirty sensor.The sensor will then have to be cleaned <br /> or replaced. <br /> The PAD200-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to <br /> the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. <br /> NOTE.As required by NFPA,do not install the sensors until all construction is complete and the work area has been thoroughly cleaned.If the sensors <br /> have been installed in a construction environment,they should be cleaned or replaced before the system is placed into service. <br /> Spacing <br /> The PAD200-PD is UL listed with a recommended maximum spacing of 30 feet.Refer to NFPA 72 for specific information regarding detector spacing, <br /> placement and special applications. <br /> Compatible Bases <br /> All bases will mount on a single gang,double gang,octagon,4"square or mud ring electrical box. <br /> Device Description Stock No. <br /> PAD100-4DB 4"Standard Base 3992731 <br /> PAD100-61)B 6"Standard Base 3992732 <br /> PAD100-I13 6"base with an isolator module included. 3992730 <br /> PAD100-RB 6"base with one Form-C relay contact. 2A @ 30VDC,0.5A @ 125VAC 3992728 <br /> PAD 100-SB 6"base with sounder module included.Sound pattern is provided from external source. 3992729 <br /> PAD100-SPKB 6"base with speaker included 3992762 <br /> Ordering Information <br /> Model Description Stock No. <br /> PAD200-PD Photoelectric Smoke Sensor 13992770 <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830172-REV A 5/21 PAGE 2 OF 2 <br />