My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-233 2024-03-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-233
>
3003 W CASINO RD BLDG 45-233 2024-03-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2024 9:37:53 AM
Creation date
2/14/2024 11:20:49 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-233
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. Documentation Cabinet-A documentation cabinet labeled "SYSTEM RECORD ❑ ❑ ❑ <br /> DOCUMENTS" shall be installed at the system control unit or at another approved <br /> location accessible only to authorized personnel. <br /> Step 3: Maximum Load Test - Secondary Power PASS FAIL N/A <br /> 1. Manual Fire Alarm box-While on battery power, initiate an Alarm by pulling the ❑ ❑ ❑ <br /> manual fire alarm box located at the FACP. <br /> 2. 90 Second Alarm Signal -Verify that the remote Central Station has received a fire ❑ ❑ ❑ <br /> alarm signal within ninety(90) seconds. Let alarm continue during next step. <br /> 3. 5 - 15 Minute Test- Let alarm continue for a minimum of 5 minutes for general ❑ ❑ ❑ <br /> occupant notification and 15 minutes for voice Evacuation.This is will give enough <br /> time to verify operation of all notification appliances throughout the facility. <br /> Audible Alarm Notification Appliances: <br /> PASS FAIL N/A <br /> 4. Per Plans-Verify annunciators are installed per approved plans ❑ ❑ ❑ <br /> 5. Audible Sound -Audible alarms devices must be 15 dBA above normal ambient ❑ ❑ ❑ <br /> sound level in all occupiable areas of building. <br /> 6. Signal Pattern -Audible signal pattern used to notify building occupants of the ❑ ❑ ❑ <br /> need to evacuate shall be the standard alarm evacuation signal consisting of a <br /> three-pulse temporal pattern. <br /> 7. Mounting-Wall-mounted appliances shall have their tops above the finished floor ❑ ❑ ❑ <br /> at heights of not less than 90 inches and below the finished ceilings at distances of <br /> not less than 6 inches. Ceiling-mounted or recessed appliances shall be permitted. <br /> 8. Combination Audible/Visible-Combination audible/visible appliances shall be ❑ ❑ ❑ <br /> installed as per the requirements for a visible alarm notification appliance. <br /> 9. Environment-Verify that all appliances as listed for the environment that they are ❑ ❑ ❑ <br /> located. (walk-in coolers/freezers, etc.) <br /> 10. Guards/Cover/Lenses-Appliances subject to mechanical damage shall be suitably ❑ ❑ ❑ <br /> protected by a guard, cover, or lenses that is listed for use with the appliance. <br /> Visible Alarm Notification Appliances: <br /> PASS FAIL N/A <br /> 11. Per Plans- Ensure the cd matches what was indicated on the plans. ❑ ❑ ❑ <br /> Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire INFORMATION HANDOUT C-5 4.13.2020 I Page 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.