Laserfiche WebLink
12. Flashing Notifications- Indoor strobes must flash 60-120 times/minute and in ❑ ❑ ❑ <br /> spaces such as corridors where more than two visible notification appliances are in <br /> any field of view, they shall flash in synchronization. <br /> 13. Lights- Lights used for fire alarm signaling only or to signal the intent for complete ❑ ❑ ❑ <br /> evacuation shall be clear or nominal white. <br /> 14. Wall Mount-Wall-mounted appliances shall be mounted such that the entire lens ❑ ❑ ❑ <br /> is not less than 80 inches and not greater than 96 inches above the finished floor. <br /> 15. Ceiling Mount-Ceiling-mounted appliances shall be permitted. If ceiling heights ❑ ❑ ❑ <br /> exceed 30 feet, ceiling-mounted visible notification appliances shall be suspended <br /> at or below 30 feet or at the mounting height of a wall mounted visible <br /> notification appliances. <br /> 16. Environment-Verify that all appliances as listed for the environment that they are ❑ ❑ ❑ <br /> located. (walk-in coolers/freezers, etc.) <br /> Step 4: Power Supplies & Trouble Signals PASS FAIL N/A <br /> 1. Reset-Once all notification appliances have been verified and the minimum alarm ❑ ❑ ❑ <br /> time has elapsed, silence the signal and ensure horns and strobes cease. <br /> 2. Clear Panel- Have primary power turned back on and verify that the panel has ❑ ❑ ❑ <br /> been cleared. <br /> 3. Battery Lead- Unplug one battery lead,the panel shall indicate a trouble within ❑ ❑ ❑ <br /> 200 seconds. <br /> 4. Battery Date-Also, ensure the battery manufacture date is written on the ❑ ❑ ❑ <br /> batteries. <br /> 5. Batterie Size-Compare the calculated size of batteries in submittal to actual ❑ ❑ ❑ <br /> batteries installed. <br /> 6. Ground Fault- Have the installer create a ground fault on the system,to ensure ❑ ❑ ❑ <br /> that the trouble condition and ground fault is annunciated on the FACP. <br /> 7. DACT- Have the alarm technician disconnect the primary line from the DACT to ❑ ❑ ❑ <br /> confirm a trouble signal on-site and transmission of a trouble signal to the <br /> supervision station within 4 minutes. Repeat this process with the secondary line. <br /> 8. Notification Appliance- Remove a wire from a notification appliance.The system ❑ ❑ ❑ <br /> shall go into trouble at the FACP within 200 seconds. <br /> 9. Smoke Detector- Remove a smoke detector from its base and ensure a trouble is ❑ ❑ ❑ <br /> shown on the panel within 200 seconds. <br /> Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-5 4.13.2020 I Page 4 <br />